Pepperl+Fuchs Explosion Protection
Choose a subcategory:
Show all categories
- 1-channel
- Installation in Zone 1
- WirelessHART Adapter
- Battery operated
- Also supplies field device
- Input 2-wire HART transmitters and 2-wire HART current sources
- Output WirelessHART wireless interface
- Direct mounting on HART or 4 mA ... 20 mA field device
- Rotatable antenna
- Installation in Zone 1, 21
- Installation in Class I, II, Division 1
- Installation in Class III
- Ex d housing for Ex d field devices
- Cast aluminum housing
- Loop powered
- Direct mounting on HART or 4 mA ... 20 mA field device
- Encapsulated antenna
- Up to 8 field devices in multidrop
- MODBUS WirelessHART Gateway
- Graphical network analysis
- Simple and automatic configuration options
- Ethernet and RS 485 interface
- HART and MODBUS protocol via both interfaces
- Input WirelessHART wireless interface
- 24 V DC supply
- Redundant power supply connections
- EtherNet/IP WirelessHART Gateway
- Graphical network analysis
- Simple and automatic configuration options
- Ethernet and RS 485 interface
- HART protocol via both interfaces
- EtherNet/IP protocol via Ethernet interface
- Input WirelessHART wireless interface
- 24 V DC supply
- Redundant power supply connections
- 2-channel
- Installation in Zone 1
- WirelessHART converter
- Battery operated
- Thermocouple or RTD input
- Output WirelessHART wireless interface
- Internal antenna
Purge &Pressurization
- Suitable for Zone 1 21 operation, ATEX/IECE certification
- Manifold combines the digital valve for purging and the needle valve for pressurization in one housing
- Suitable for steel or plastic tubing
- Mounting hardware, pneumatic fittings and tubing included
- Ex e and Ex tb certified
- Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22
- Stainless Steel
- Thread NPT 1/2''
- Seal silicone
- Packaging unit: 35 pieces, with accessories
- Adjustable output 15 ... 30 V/max.1 A
- 8 hours operation at 500 mA without recharging
- IP 54 - Rain and splash proof
- Rugged housing for outdoor use
- For FOUNDATION Fieldbus H1 and PROFIBUS PA
- Low battery and overload indication
- Output current meter
- Selectable terminators for creating any type of termination
- All in one - no additional components required
Segment Protector F2-SP-IC* F2-SP-IC08.1.03.03.00
- Connection plate for HART multiplexer in K system
- 16-way version
- Interface for serial or parallel connection
- Built-in switchable 220 resistor
- Connection by screw terminals
- Output: 28 ... 30 V/500 mA
- High-power trunk for high device count and long cable lengths
- With galvanic isolation
- Installation in Zone 2/Class I, Div. 2
- For FOUNDATION Fieldbus H1 and PROFIBUS PA
- Highest efficiency, lowest heat dissipation for highest packing density
- Hot swappable in redundant configuration
- Module exchange without tools during operation
- 8 segments, redundant, individual modules per segment
- Supports all PLC and PCS hosts, redundant terminals
- High-power trunk: Live work on devices in any hazardous area
- Best quality, smallest size and lowest heat dissipation
- For FOUNDATION Fieldbus H1 and PROFIBUS PA
- Optional advanced diagnostics
- Passive impedance for high reliability
- Supports Ex ic voltage limitation
- Installation in Zone 2/Div. 2
Temperature Multi-Input Device for Cabinet Installation
- 22 inch TFT display w/ optional touch screen
- Widescreen 16:10 aspect ratio
- Seams continuously welded and ground smooth (Type 4/4X, IP66)
- Replaceable SIM
- Global certificates - a common hardware platform
- Wireless connections such as WWAN, 4G LTE, WLAN, etc.
- NFPA 70, NFPA 496, ISA 12.4 standards
- Optional alarm output indicates air lock failure
- Type Y system certified for Class I and Class II, Division 1 to Division 2
- Type Z system certified for Class I and Class II, Division 2 to nonhazardous area
- Class I enclosure volume up to 2 ft3
- Class II enclosure volume up to 10 ft3
TYPE YZ
TYPE YZ
Purge &Pressurization
Purge&Pressurization
Purge&Pressurization
Purge&Pressurization
- NFPA 70, NFPA 496, ISA 12.4 standards
- Optional alarm output indicates air lock failure
- Type Z system certified for Class I, Division 2 to nonhazardous
- Enclosure volume up to 15 ft3