Pepperl+Fuchs Explosion Protection

Choose a subcategory:

Show all categories
  • 1-channel
  • Installation in Zone 1
  • WirelessHART Adapter
  • Battery operated
  • Also supplies field device
  • Input 2-wire HART transmitters and 2-wire HART current sources
  • Output WirelessHART wireless interface
  • Direct mounting on HART or 4 mA ... 20 mA field device
  • Rotatable antenna
  • Installation in Zone 1, 21
  • Installation in Class I, II, Division 1
  • Installation in Class III
  • Ex d housing for Ex d field devices
  • Cast aluminum housing
  • Loop powered
  • Direct mounting on HART or 4 mA ... 20 mA field device
  • Encapsulated antenna
  • Up to 8 field devices in multidrop
  • MODBUS WirelessHART Gateway
  • Graphical network analysis
  • Simple and automatic configuration options
  • Ethernet and RS 485 interface
  • HART and MODBUS protocol via both interfaces
  • Input WirelessHART wireless interface
  • 24 V DC supply
  • Redundant power supply connections
  • EtherNet/IP WirelessHART Gateway
  • Graphical network analysis
  • Simple and automatic configuration options
  • Ethernet and RS 485 interface
  • HART protocol via both interfaces
  • EtherNet/IP protocol via Ethernet interface
  • Input WirelessHART wireless interface
  • 24 V DC supply
  • Redundant power supply connections
  • 2-channel
  • Installation in Zone 1
  • WirelessHART converter
  • Battery operated
  • Thermocouple or RTD input
  • Output WirelessHART wireless interface
  • Internal antenna

Purge &Pressurization

  • Suitable for Zone 1 21 operation, ATEX/IECE certification
  • Manifold combines the digital valve for purging and the needle valve for pressurization in one housing
  • Suitable for steel or plastic tubing
  • Mounting hardware, pneumatic fittings and tubing included
  • Ex e and Ex tb certified
  • Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Stainless Steel
  • Thread NPT 1/2''
  • Seal silicone
  • Packaging unit: 35 pieces, with accessories
  • Adjustable output 15 ... 30 V/max.1 A
  • 8 hours operation at 500 mA without recharging
  • IP 54 - Rain and splash proof
  • Rugged housing for outdoor use
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Low battery and overload indication
  • Output current meter
  • Selectable terminators for creating any type of termination
  • All in one - no additional components required

Segment Protector F2-SP-IC* F2-SP-IC08.1.03.03.00

  • Connection plate for HART multiplexer in K system
  • 16-way version
  • Interface for serial or parallel connection
  • Built-in switchable 220 resistor
  • Connection by screw terminals
  • Output: 28 ... 30 V/500 mA
  • High-power trunk for high device count and long cable lengths
  • With galvanic isolation
  • Installation in Zone 2/Class I, Div. 2
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Highest efficiency, lowest heat dissipation for highest packing density
  • Hot swappable in redundant configuration
  • Module exchange without tools during operation
  • 8 segments, redundant, individual modules per segment
  • Supports all PLC and PCS hosts, redundant terminals
  • High-power trunk: Live work on devices in any hazardous area
  • Best quality, smallest size and lowest heat dissipation
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Optional advanced diagnostics
  • Passive impedance for high reliability
  • Supports Ex ic voltage limitation
  • Installation in Zone 2/Div. 2

Temperature Multi-Input Device for Cabinet Installation

  • 22 inch TFT display w/ optional touch screen
  • Widescreen 16:10 aspect ratio
  • Seams continuously welded and ground smooth (Type 4/4X, IP66)
  • Replaceable SIM
  • Global certificates - a common hardware platform
  • Wireless connections such as WWAN, 4G LTE, WLAN, etc.
  • NFPA 70, NFPA 496, ISA 12.4 standards
  • Optional alarm output indicates air lock failure
  • Type Y system certified for Class I and Class II, Division 1 to Division 2
  • Type Z system certified for Class I and Class II, Division 2 to nonhazardous area
  • Class I enclosure volume up to 2 ft3
  • Class II enclosure volume up to 10 ft3
Purge &Pressurization
Purge&Pressurization
Purge&Pressurization
  • NFPA 70, NFPA 496, ISA 12.4 standards
  • Optional alarm output indicates air lock failure
  • Type Z system certified for Class I, Division 2 to nonhazardous
  • Enclosure volume up to 15 ft3