  • Suitable for Zone 1 21 operation, ATEX/IECE certification
  • Manifold combines the digital valve for purging and the needle valve for pressurization in one housing
  • Suitable for steel or plastic tubing
  • Mounting hardware, pneumatic fittings and tubing included

Incremental rotary encoder 

  • Ex e and Ex tb certified
  • Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22
  • Stainless Steel
  • Thread NPT 1/2''
  • Seal silicone
  • Packaging unit: 35 pieces, with accessories
  • Diffuse mode sensor for recording any print mark
  • TEACH-IN, static and dynamic
  • 50 micro-s response time, suitable for extremely rapid scanning processes
  • 3 emitter colors: green, red and blue

ENA58IL S10CA5 1213B17 ABP

  • Body: AISI 303 stainless steel
  • Shaft: AISI 303 stainless steel
  • Bearings: Ball bearings
  • Sealing: EPDM

ENI58IL S10CA5 1024UD1 RC1

  • Shaft torque: Max. 1.5 Nm
  • Permissible radial load: Max. 100 N
  • Permissible axial load: Max. 50 N
  • Impact resistance: Up to 50 g
  • Vibration resistance: Up to 10 g (peak-peak)

EPV 2 SA 90

  • Sealing: EPDM, NBR
  • Maximum voltage: 250 V AC

EPV 3 SA 00

  • Maximum pressure: 0.3 bar (4.4 psi)
  • Vacuum: -0.08 bar (-1.2 psi)
  • Maximum Flow: 8 L/H (2.1 GPM)
  • Connections: G1/4, G3/8, NPT 1/8, M10 x 1
  • Sealing material: EPDM, FKM

EPV 3 SA 90

  • Diaphragm: Silicone rubber
  • Spring: Stainless steel
  • Maximum Voltage: 250V AC/DC
  • Maximum current: 10 A

EPV 6000 SS 01

  • Connection: G 1/4 A, internal thread
  • Fluid: Liquids and gases (compatible with 316L stainless steel)
  • Maximum flow rate: 30 l/min (7.925 gal/h)
  • Electrical signal: 4-20 mA
  • Supply voltage: 10...30 V DC
  • Current consumption: max. 20 mA
  • Response time: < 2 s

Segment Protector F2-SP-IC* F2-SP-IC08.1.03.03.00

Connection plate for HART multiplexer in K system
16-way version

FL2B 2J6 E

  • LED status indicator
  • Reverse polarity protection
  • CE, cULus, EAC certification

FL2B 4J6 E

  • Switching voltage: ≤ 250 V DC
  • Maximum switching current: ≤ 2 A
  • Residual current: ≤ 10 μA
  • Trigger time: ≤ 0.2 ms
  • Reset time: ≤ 0.1 ms
  • Reverse polarity protection: yes
  • Short circuit protection: yes
  • Output: 28 ... 30 V/500 mA
  • High-power trunk for high device count and long cable lengths
  • With galvanic isolation
  • Installation in Zone 2/Class I, Div. 2
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Highest efficiency, lowest heat dissipation for highest packing density
  • Hot swappable in redundant configuration
  • Module exchange without tools during operation

This item is out of production!

  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • 2-wire SMART transmitter
  • Output for 4 mA ... 20 mA or 1 V ... 5 V
  • Sink or source mode
  • Line fault detection (LFD)
  • Up to SIL 3 acc. to IEC 61508

HPV D13

  • Current consumption: < 10 mA
  • Reverse polarity protection: Yes
  • Short circuit protection: Yes
  • On/off delay time: < 2ms
  • Operating temperature: -20°C...+70°C

KFD2 CD2 EX1

  • Marking: space for marking on the front panel
  • Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1:2013 (industrial premises)
  • Degree of protection: IEC 60529:2001
  • Protection against electric shock: UL 61010-1:2004
  • Ambient temperature: -20...60 °C (-4...140 °F)

KFD2 CD2 EX2

  • Maximum current consumption: 100 mA
  • Response time: < 250 ms
  • Overcurrent protection: Yes
  • Short circuit protection: Yes
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Level sensing input
  • Adjustable range 1 k Omega- ... 150 k Omega-
  • Relay contact output
  • Fault relay contact output
  • Adjustable time delay up to 10 s
  • Minimum/maximum control
  • Line fault detection (LFD)

KFD2 GU 1

  • Resolution: 0.1°C or 0.1°F
  • Overload: 150% of the measurement range within 2 seconds
  • Short Circuit: The output is protected against short circuits to power and ground
  • Input resistance: RTD: ≤ 20 ohms
  • Thermocouple: ≤ 2 MΩ
  • Output resistance: ≤ 2 ohms
  • 2-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Current output up to 700 Omega- load
  • HART I/P and valve positioner
  • Line fault detection (LFD)
  • Accuracy 0.05 %
  • Terminal blocks with test sockets
  • Up to SIL 2 acc. to IEC 61508
  • 2-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Usable as signal splitter (1 input and 2 outputs)
  • 2 x 2 relay contact outputs with AND logic
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc. to IEC 61508

KFD2 STC4 2

  • Connection: Screw terminals
  • Mounting: On a 35 mm DIN rail according to EN 60715: 2001
  • EC type conformity certificate: BAS 99 ATEX 7025 X
  • Certificate: TÜV 99 ATEX 1499 X
  • IECEx certificate: IECEx BAS 04.0015X IECEx CML 15.0055X
  • 2-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Input 2-wire SMART transmitters
  • Output 0/4 mA ... 20 mA current sink
  • Terminal blocks with test sockets
  • Up to SIL 2 acc. to IEC 61508

KFD2 STV4 EX2 2

  • Input Impedance: Approx. 200 ohms
  • Maximum input voltage: 30 V
  • Reverse polarity protection: Built-in protection
  • Overcurrent protection: Built-in protection


LFL2 BK U PUR5

  • Rated voltage: 250 V AC / 150 V DC
  • Maximum current: 1 A DC / 3 A AC
  • Minimum switching current: 10 mA
  • Electrical strength: 2000 V AC
  • Degree of insulation resistance: > 100 MΩ
  • Voltage drop across contacts: < 1 V at nominal current
  • Switching time: < 10 ms

LFL2 CK U PUR3

  • Maximum switching power: 750 VA
  • Minimum switching current: 10 μA
  • Minimum switching power: 0.25 VA
  • Trigger time: < 10 ms
  • Trigger time: < 10 ms
  • Electrical strength: 2000 V AC
  • Insulation resistance: > 100 MΩ

LFL2 CK U PUR5

  • Process pressure (static pressure): ≤ 3 bar (43.5 psi) at 20°C (68°F)
  • Density: ≥ 0.8 g/cm³
  • Ambient temperature: 5 ... 70°C (41 ... 158°F)
  • Storage temperature: -25 ... 70°C (-13 ... 158°F)
  • Altitude: ≤ 2000 m above sea level
  • Degree of protection: IP68