Pepperl+Fuchs
Choose a subcategory:
Show all categories
Ultrasonic sensor
Connection cable
Gateway and safety monitor in one housing
Connection to Ethernet Modbus TCP/IP
SafeLink
Integrated data decoupling
Gateway compliant with AS-Interface specification 3.0
Connection to PROFINET IO
Fault diagnosis via LEDs and grafic display
Easy commissioning by graphic display
- Enables easy, centralized management of a Remote Monitor via the VisuNet Control Center
- Allows you to directly connect from a VisuNet Remote Monitor to a virtualized Emerson DeltaV system
- Enables easy, centralized management of a Remote Monitor via the VisuNet Control Center
Array control panel with highly visible LED display
Flashing power on LED in case of short-circuit
Evaluation board for VOS cameras VOS-PROG1
Vision Sensor
WCS interface module
- 1-channel
- Installation in Zone 1, Zone 21, and Class I Div. 1
- WirelessHART Adapter
- Battery operated
- Also supplies field device
- Input 2-wire HART transmitters and 2-wire HART current sources
- Output WirelessHART wireless interface
- Direct mounting on HART or 4 mA ... 20 mA field device
- Rotatable antenna
- 1-channel
- WirelessHART Adapter
- Battery operated
- Also supplies field device
- Input 2-wire HART transmitters and 2-wire HART current sources
- Output WirelessHART wireless interface
- Direct mounting on HART or 4 mA ... 20 mA field device
- Rotatable antenna
- 1-channel
- Installation in Zone 1
- WirelessHART Adapter
- Battery operated
- Also supplies field device
- Input 2-wire HART transmitters and 2-wire HART current sources
- Output WirelessHART wireless interface
- Direct mounting on HART or 4 mA ... 20 mA field device
- Rotatable antenna
- Installation in Zone 1, 21
- Installation in Class I, II, Division 1
- Installation in Class III
- Ex d housing for Ex d field devices
- Cast aluminum housing
- Loop powered
- Direct mounting on HART or 4 mA ... 20 mA field device
- Encapsulated antenna
- Up to 8 field devices in multidrop
- MODBUS WirelessHART Gateway
- Graphical network analysis
- Simple and automatic configuration options
- Ethernet and RS 485 interface
- HART and MODBUS protocol via both interfaces
- Input WirelessHART wireless interface
- 24 V DC supply
- Redundant power supply connections
- EtherNet/IP WirelessHART Gateway
- Graphical network analysis
- Simple and automatic configuration options
- Ethernet and RS 485 interface
- HART protocol via both interfaces
- EtherNet/IP protocol via Ethernet interface
- Input WirelessHART wireless interface
- 24 V DC supply
- Redundant power supply connections
- 2-channel
- Installation in Zone 1
- WirelessHART converter
- Battery operated
- Thermocouple or RTD input
- Output WirelessHART wireless interface
- Internal antenna
Sensing range | 50 ... 300 mm |
Rated ultrasonic frequency | 400 kHz |
Output voltage | 0 ... 10 V |
- 316 SS
- External Mount
- 20-30VDC
- M2
Purge &Pressurization
- Suitable for Zone 1 21 operation, ATEX/IECE certification
- Manifold combines the digital valve for purging and the needle valve for pressurization in one housing
- Suitable for steel or plastic tubing
- Mounting hardware, pneumatic fittings and tubing included
Incremental rotary encoder
- Ex e and Ex tb certified
- Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22
- Stainless Steel
- Thread NPT 1/2''
- Seal silicone
- Packaging unit: 35 pieces, with accessories
- Diffuse mode sensor for recording any print mark
- TEACH-IN, static and dynamic
- 50 micro-s response time, suitable for extremely rapid scanning processes
- 3 emitter colors: green, red and blue
Segment Protector F2-SP-IC* F2-SP-IC08.1.03.03.00
Connection plate for HART multiplexer in K system
16-way version