Pepperl+Fuchs

Choose a subcategory:

Show all categories
  • 1-channel signal conditioner

  • 24 V DC supply (Power Rail)

  • 1-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Current and voltage input
  • 2 relay contact outputs
  • Programmable high/low alarm
  • Configurable via DIP switches and potentiometer
  • Terminal blocks with test sockets
  • 1-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Thermocouple, RTD, potentiometer or voltage input
  • Redundant TC input
  • Current output 0/4 mA ... 20 mA
  • 2 relay contact outputs
  • Configurable by PACTware or keypad
  • Line fault (LFD) and sensor burnout detection
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • 1-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • 2-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • 1-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • 1-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • 2-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • 2-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • 2-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • 2-channel signal conditioner

  • 24 V DC supply

  • PNP/push-pull, dry contacts or NAMUR inputs

  • 1-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • 1-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • Dry contact or NAMUR inputs

  • 1-channel isolated barrier

  • 24 V DC supply (Power Rail)

SMART Transmitter Power Supply

  • 1-channel signal conditioner

  • 24 V DC supply (Power Rail)

  • 2-channel signal conditioner

  • 24 V DC supply (Power Rail)

  • 1-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources

  • 1-channel signal conditioner

  • 24 V DC supply (Power Rail)

  • Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts

  • 1-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • Input for NAMUR sensors or dry contacts

  • 2-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Input frequency 1 mHz ... 1 kHz
  • Current output 0/4 mA ... 20 mA
  • Relay contact and transistor output
  • Start-up override
  • Configurable by PACTware or keypad
  • Line fault detection (LFD)
  • 1-channel signal conditioner

  • 24 V DC supply (Power Rail)

  • Scaleable current or voltage input

  • 2-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Thermocouple, RTD, potentiometer or voltage input
  • Usable as signal splitter (1 input and 2 outputs)
  • Voltage output 0/1 V ... 5 V
  • Configurable by PACTware
  • Line fault (LFD) and sensor burnout detection
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • 1-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • Thermocouple, RTD, potentiometer or voltage input

  • 1-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • 1-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • Voltage input 0 V ... -20 V

  • 1-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Strain gauge input (full or half bridge)
  • Output 0 mA ... В± 20 mA or 0 V ... В± 10 V
  • 2 relay contact outputs
  • Programmable high/low alarm
  • Configurable by PACTware or keypad
  • RS-485 interface
  • Line fault detection (LFD)
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Strain gauge input (full or half bridge)
  • Output 0 mA ... В± 20 mA or 0 V ... В± 10 V
  • 2 relay contact outputs
  • Programmable high/low alarm
  • Configurable by PACTware or keypad
  • RS-485 interface
  • Low response time
  • Line fault detection (LFD)
  • 1-channel signal conditioner
  • Universal usage at different power supplies
  • Thermocouple, RTD, potentiometer or voltage input
  • Redundant TC input
  • Current output 0/4 mA ... 20 mA
  • 2 relay contact outputs
  • Configurable by PACTware or keypad
  • Line fault (LFD) and sensor burnout detection
  • Up to SIL 2 acc. to IEC 61508/IEC 61511