Pepperl+Fuchs

Choose a subcategory:

Show all categories
  • 8-channel
  • Outputs Ex ib
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Galvanic group isolation
  • Line fault detection (LFD)
  • Positive or negative logic selectable
  • Simulation mode for service operations (forcing)
  • Permanently self-monitoring
  • Output with watchdog
  • Output with bus-independent safety shutdown input
  • 8-channel
  • Outputs Ex ib
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Galvanic group isolation
  • Line fault detection (LFD)
  • Positive or negative logic selectable
  • Simulation mode for service operations (forcing)
  • Permanently self-monitoring
  • Output with watchdog
  • Output with bus-independent safety shutdown
  • 8-channel
  • Outputs with plug-in Ex e terminals
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Line fault detection (LFD)
  • Positive or negative logic selectable
  • Simulation mode for service operations (forcing)
  • Permanently self-monitoring
  • Output with watchdog
  • Output with bus-independent safety shutdown input
  • Output with bus-independent safety shutdown
  • Interface between the I/O modules and the PCS/PLC
  • Com unit for 80 analog or 184 digital channels
  • Communication via MODBUS TCP
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • HART communication via MODBUS TCP
  • Configuration via FDT 1.2 DTM
  • Non-volatile memory for configuration and parameter settings
  • Self configuration in redundant systems
  • Permanently self-monitoring
  • Outputs drive to safe state in case of failures
  • Standard enclosure for FB-System
  • Max. 5 slots for I/O modules
  • For FOUNDATION Fieldbus H1
  • Impact resistance enclosure, IP66/NEMA 4X
  • Packaged certified solution
  • Installation in Zone 1
  • 8 segments, individual modules per segment
  • Supports all PLC and PCS hosts
  • High-power trunk: Live work on devices in any hazardous area
  • Features for best signal quality, low heat dissipation
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Optional advanced diagnostics
  • Passive impedance and CREST technology for high reliability
  • Supports Ex ic/nL voltage limitation
  • Installation in Zone 2/Div. 2
  • 4 segments, redundant, individual modules per segment
  • Supports all PLC and PCS hosts
  • High-power trunk: Live work on devices in any hazardous area
  • Features for best signal quality, low heat dissipation
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Optional advanced diagnostics
  • Passive impedance and CREST technology for high reliability
  • Supports Ex ic/nL voltage limitation
  • Installation in Zone 2/Div. 2
  • 8 segments, redundant, individual modules per segment
  • Customized for Invensys, FBM228
  • High-power trunk: Live work on devices in any hazardous area
  • Best quality, smallest size and lowest heat dissipation
  • For FOUNDATION Fieldbus H1
  • Optional advanced diagnostics
  • Passive impedance for high reliability
  • Dual, redundant bulk power connections
  • Comprehensive diagnostics for the fieldbus physical layer
  • Handheld with display and integrated expert system
  • Fieldbus interface Ex ia, FISCO, Entity, and DART
  • For commissioning, online monitoring and troubleshooting
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Multi-language support
  • Operation in Zone 1/Class I, Div. 1
  • Choice of power options for different operating modes
  • PC software for enhanced interface and data backup
  • Comprehensive diagnostics for fieldbus physical layer and power supply
  • Plug-in Module for the FieldConnex Power Hub
  • Precise measurements through passive circuits
  • For commissioning, online monitoring and troubleshooting
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Installation in Zone 2/Class I, Div. 2
  • System state and fault indication via LEDs
  • Display of data in the safety of the control room
  • Automatic setup of diagnostic system
  • Full software integration into PCS and PAM possible
  • Diagnostics for fieldbus physical layer and power supply
  • Plug-in Module for the FieldConnex Power Hub
  • Plug and play - no engineering required
  • For online monitoring
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Installation in Zone 2/Class I, Div. 2
  • System state and fault indication via LEDs
  • Alarm limits configurable via DIP switches
  • Fault indication transmission by voltage free contact
  • Output: 15 ... 17 V/500 mA
  • Voltage limitation for FISCO ic, Entity ic, also FNICO and Ex nL
  • With galvanic isolation
  • Installation in Zone 2/Class I, Div. 2
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • High efficiency, low heat dissipation for high packing density
  • Hot swappable in redundant configuration
  • Module exchange without tools during operation
  • Output: 21 ... 23 V/500 mA
  • Voltage limitation for Entity ic and Ex nL
  • With galvanic isolation
  • Installation in Zone 2/Class I, Div. 2
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • High efficiency, low heat dissipation for high packing density
  • Hot swappable in redundant configuration
  • Module exchange without tools during operation
  • Output: 28 ... 30 V/500 mA
  • High-power trunk for high device count and long cable lengths
  • With galvanic isolation
  • Installation in Zone 2/Class I, Div. 2
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • High efficiency, low heat dissipation for high packing density
  • Hot swappable in redundant configuration
  • Module exchange without tools during operation
  • PROFIBUS DP V1 / For 4 segments PA
  • Couples PROFIBUS PA devices transparently to PROFIBUS DP
  • Optional redundant configuration
  • Installation in Zone 2/Class I, Div. 2
  • Up to 12 Mbit/s, auto adapting
  • For redundant and non-redundant masters
  • Supports Flying Redundancy (FR)
  • Cyclic/acyclic data exchange
  • Gateway PROFINET RT to 4 x PROFIBUS PA segments
  • Up to 32 devices per PROFIBUS PA segment
  • Installation in Zone 2/Class I, Div. 2
  • Ring and system redundancy
  • Integrated webserver for diagnostics
  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Input for 2-wire SMART transmitters and current sources
  • Signal splitter (1 input and 2 outputs)
  • Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V
  • Up to SIL 3 acc. to IEC 61508
  • System board for HIMA, HIMax
  • For 16-channel card X-AO 1601 (AO, single mode)
  • 16-channel card X-AO 1601 (AO, redundant mode on request)
  • For 16 modules
  • Recommended module: HiC2031 (AO)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: HIMA system connector, 96-pin
  • System board for Triconex (approval TAN48)
  • For 32-channel AI cards 3700A, and 3721
  • For 16 modules
  • Recommended module: HiC2025 (AI)
  • 24 V DC supply
  • Hazardous area: pluggable screw terminals, blue
  • Safe area: ELCO socket, 56-pin
  • System board for Yokogawa CENTUM VP
  • For 16-channel AI/AO card AAB841
  • For 16 modules
  • Recommended modules: HiC2025 (AI), HiC2031 (AO)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: Yokogawa system connector, 40-pin
  • System board for HIMA, HIMax
  • For 32-channel cards X-AI 32 01 or X-AI 32 02 (AI)
  • For 32 modules
  • Recommended modules: HiC2025 (AI), HiC2081 (TI)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: HIMA system connector, 96-pin
  • System board for HIMA, HIMax
  • For 32-channel cards X-DI 32 01 or X-DI 32 04 (DI)
  • For 32 modules
  • Recommended modules: HiC2821 (DI), HiC2841 (DI)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: HIMA system connector, 96-pin
  • System board for HIMA, HIMax
  • For 32-channel card X-DO 32 01 (DO)
  • For 32 modules
  • Recommended module: HiC2873 (DO)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: HIMA system connector, 96-pin
  • System board for HIMA, HIMax
  • For 32-channel cards X-AI 32 01 or X-AI 32 02 (AI)
  • For 32 modules
  • Recommended module: HiC2027 (AI)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: HIMA system connector, 96-pin
  • Safe area: spring terminals, black
  • System board for Triconex (approval TAN48)
  • For 64-channel (32+32) AI cards 3704E and 3720
  • For 32 modules
  • Recommended module: HiC2025 (AI)
  • 24 V DC supply
  • Hazardous area: pluggable screw terminals, blue
  • Safe area: ELCO socket, 56-pin
  • System board for Triconex (approval TAN48)
  • For 64-channel (32+32) DI card 3564
  • For 32 modules
  • Recommended module: HiC2821 (DI)
  • 24 V DC supply
  • Hazardous area: pluggable screw terminals, blue
  • Safe area: ELCO socket, 56-pin
  • 4-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Analog in or analog out signals
  • Sink and source mode outputs
  • SMART pass-through
  • Up to SIL 2 acc. to IEC 61508
  • 2-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Current output up to 750 Omega- load
  • SMART I/P and valve positioners
  • Suitable for Yokogawa PCS system
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508
  • 32-channel
  • 24 V DC supply
  • HART field device input (revision 5 to 7)
  • RS-485 interface
  • Up to SIL 3 acc. to IEC 61508
  • System board for HIMA, HIMax
  • For 32-channel cards X-AI 32 01 or X-AI 32 02 (AI)
  • For 16 modules
  • Recommended module: HiD2030 (AI), HiD2082 (Temp.)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: HIMA system connector, 96-pin

in international format without spaces
All fields are required