Pepperl+Fuchs

Choose a subcategory:
Show all categories
  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Input for 2-wire SMART transmitters and current sources
  • Signal splitter (1 input and 2 outputs)
  • Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V
  • Up to SIL 3 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Dry contact or NAMUR input
  • Usable as signal splitter (1 input and 2 outputs)
  • 2 passive transistor outputs
  • 1-channel isolated barrier
  • 24 V DC supply (bus or loop powered)
  • Output 45 mA at 12 V DC
  • Line fault transparency (LFT)
  • Test pulse immunity
  • Up to SIL 3 acc. to IEC/EN 61508
  • System board for HIMA, HIMax
  • For 16-channel card X-AO 1601 (AO, single mode)
  • 16-channel card X-AO 1601 (AO, redundant mode on request)
  • For 16 modules
  • Recommended module: HiC2031 (AO)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: HIMA system connector, 96-pin
  • System board for Triconex (approval TAN48)
  • For 32-channel AI cards 3700A, and 3721
  • For 16 modules
  • Recommended module: HiC2025 (AI)
  • 24 V DC supply
  • Hazardous area: pluggable screw terminals, blue
  • Safe area: ELCO socket, 56-pin
  • System board for Yokogawa CENTUM VP
  • For 16-channel AI cards AAI143, AAB141-H
  • For 16 modules
  • Recommended modules: HiC2025(A) (AI), HiC2081 (TI)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Non-hazardous area: Yokogawa system connector, 40-pin
  • System board for Yokogawa CENTUM VP
  • For 16-channel AI/AO card AAB841
  • For 16 modules
  • Recommended modules: HiC2025 (AI), HiC2031 (AO)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: Yokogawa system connector, 40-pin
  • System board for HIMA, HIMax
  • For 32-channel cards X-AI 32 01 or X-AI 32 02 (AI)
  • For 32 modules
  • Recommended modules: HiC2025 (AI), HiC2081 (TI)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: HIMA system connector, 96-pin

This item is out of production!

  • 4-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Analog in or analog out signals
  • Sink and source mode outputs
  • SMART pass-through
  • Up to SIL 2 acc. to IEC 61508

This item is out of production!

2-channel isolated barrier

This item is out of production!

This Item is out of Production!

2-channel, 24 V DC supply, Current output up to 750 Omega- load

  • 32-channel
  • 24 V DC supply
  • HART field device input (revision 5 to 7)
  • RS-485 interface
  • Up to SIL 3 acc. to IEC 61508
  • 32-channel
  • 24 V DC supply
  • Interface for serial or parallel wiring options
  • Dual RS 485 connections
  • Slot for HART Multiplexer
  • Ideal for retrofitting existing installations
  • Interface for serial or parallel wiring options
  • 37-pin Sub-D connectors
  • Redundant power supply connections
  • HART filter options
  • Fuse options
  • 32-channel
  • 24 V DC supply
  • For analog output cards
  • HART output filters
  • Interface for serial or parallel wiring options
  • 37-pin Sub-D connectors
  • Slot for HART Multiplexer
  • TDC 3000 replacement FTA
  • Short-circuit protected
  • Redundant PCS wirings
  • Redundant power supply connections
  • Field terminal blocks that are Honeywell FTA compatible
  • Honeywell ""B"" size footprint
  • Triconex 3700A and 3721 replacement FTA
  • 2- or 3-wire or self powered transmitters
  • Outputs: 2 x 16 channels, 0 V ... 10 V differential, DC coupled (makes 32 channels)
  • Short-circuit protected
  • Plug-n-play wiring capabilities
  • Triconex 3700A and 3721 replacement FTA
  • 2- or 3-wire or self powered transmitters
  • Outputs: 2 x 16 channels, 0 V ... 10 V differential, DC coupled (makes 32 channels)
  • Short-circuit protected
  • Plug-n-play wiring capabilities
  • Optimized for use in floating power configurations
  • Triconex 3704E and 3720 replacement FTA
  • 2- or 3-wire or self powered transmitters
  • Outputs: 1 x 32 channels, 0 V ... 5 V differential, DC coupled
  • Short-circuit protected
  • Plug-n-play wiring capabilities
  • Triconex 3805E replacement FTA
  • 32 channels of I/O
  • Outputs: 4 x 8 channels, 4 mA ... 20 mA current loop, DC coupled
  • Short-circuit protected
  • HART analog output filters
  • Interface for wireless communication between PC host and any HART field device
  • Registered with HART Communication Foundation
  • ATEX and IECEx approval
  • UL listed for North America
  • Powerful, high-speed Bluetooth with 100 m open-air range
  • Adaptive frequency hopping to reduce radio-frequency interference
  • HARTCommDTM software supports use with FDT Frame applications
  • Compatible with 32- and 64-bit Windows?® 7, 8, XP, 10, or Vista
  • HART compliant for communication with any HART field device and error-free slave testing
  • Draws power from USB port, needs no external supply to power modem
  • Compact, rugged polycarbonate housing for industrial-grade reliability
  • Quickly power and communicate with HART field devices
  • Powers all 2-wire HART devices, independent of supplier
  • Draws power from USB port, needs no external supply to power modem
  • Compact, rugged polycarbonate housing for industrial-grade reliability
  • Integrated connector cable terminates in 2 test clips and 1 USB connector cable
  • Selectable powered-modem or modem-only mode
  • Compatible with 32- and 64-bit Windows?® 7, 8, XP, 10, or Vista
  • For installation of power distribution networks
  • 316L Stainless Steel
  • Ex e certified
  • M10 internal/external brass earth stud
  • Installation in Zone 1, Zone 2, Zone 21 and Zone 22
  • 977 mm x 677 mm x 300 mm
  • 1-channel
  • Loop powered
  • NAMUR sensor simulator and pulse generator
  • Simulates line faults

HART Connection Cable with Connectors

  • 2-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Analog input (AI), Analog output (AO)
  • Operates as transmitter power supply or current driver
  • Housing width 12.5 mm
  • Up to SIL 2 (SC 3) acc. to IEC/EN 61508
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Line fault detection (LFD)
  • Housing width 12.5 mm
  • Up to SIL 2 (SC 3) acc. to IEC/EN 61508
  • 1-channel isolated barrier

  • 24 V DC supply (loop powered)

  • 1-channel isolated barrier

  • 24 V DC supply (loop powered)

  • Current input/output 0 mA ... 40 mA