Pepperl+Fuchs FB6208C

Digital Output with Shutdown Input
Pepperl+Fuchs FB6208C
849.66
One click request

Dimensions57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch)

Electromagnetic compatibilityNE 21
EU-Type Examination CertificatePTB 97 ATEX 1074 U
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Codingoptional mechanical coding via front socket
Rated voltage12 V DC , only in connection with the power supplies FB92**
Connectionbackplane bus
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Response time20 ms (depending on bus cycle time)
Power dissipation2.35 W
LED indicationLED green: supply
LED red: line fault , communication error red flashing
Relative humidity95 % non-condensing
Massapprox. 750 g
ATEX approvalPTB 97 ATEX 1075 ; PTB 97 ATEX 1074 U
Occupied slots2
Environmental testEN 60068-2-14
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Power consumption2.35 W
Relative humidityEN 60068-2-56
EAC approvalRussia: RU C-IT.MIII06.B.00129
Current limit5.2 mA
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Number of channels8
Degree of protectionIP20 (module) , a separate housing is required acc. to the system description
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Open loop voltage21.6 V
Connectionbackplane bus
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Degree of protectionIEC 60529
Line fault detectioncan be switched on/off for each channel via configuration tool
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Connectionchannel I: 1+, 2-; channel II: 3+, 4-; channel III: 5+, 6-; channel IV: 7+, 8-; channel V: 9+, 10-; channel VI: 11+, 12-; channel VII: 13+, 14-; channel VIII: 15+, 16-
System informationThe module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.
Interfacemanufacturer-specific bus to standard com unit
Watchdogwithin 0.5 s the device goes in safe state, e.g. after loss of communication
Damaging gasEN 60068-2-42
in international format without spaces
All fields are required