Pepperl+Fuchs LB5101A

RTD Converter
Pepperl+Fuchs LB5101A
Price on Request
One click request
Massapprox. 90 g
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance
Measuring current200 andmicro;A
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Degree of protectionIEC 60529
Rated voltage12 V DC , only in connection with the power supplies LB9***
Line fault detectioncan be switched on/off for each channel via configuration tool
Conversion timemax. 20 ms without LFD max. 150 ms with LFD
Slide-wire sensor10 ... 400 andOmega;
Power consumption0.4 W
Vibration resistanceEN 60068-2-6
Linearity error0.1 %
Dimensions16 x 100 x 102 mm (0.63 x 3.9 x 4 inch)
Relative humidity95 % non-condensing
Degree of protectionIP20 when mounted on backplane
System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity.
For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
LED indicationPower LED (P) green: supply
Status LED (1) red: line fault
Connectionbackplane bus
UL approvalE106378
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Environmental testEN 60068-2-14
Lead resistancemax. 50 andOmega; per strand
Connectionbackplane bus
Electromagnetic compatibilityNE 21
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Shock resistanceEN 60068-2-27
Connectionremovable front connector with screw flange (accessory)
wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Number of channels1
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Measurement range10 ... 400 andOmega; (500 andOmega; incl. line resistance)
Interfacemanufacturer-specific bus to standard com unit
IECEx approvalBVS 09.0037X
EU-Type Examination CertificatePTB 03 ATEX 2042
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Damaging gasEN 60068-2-42
Connection2-wire connection: 5, 6
3-wire connection: 1, 5, 6
4-wire connection: 1, 2, 5, 6
Smallest span20 andOmega; for 0.1 % accuracy
Relative humidityEN 60068-2-56
CertificatePF 08 CERT 1234 X
ATEX approvalPTB 03 ATEX 2042
Power dissipation0.4 W
Occupied slots1
Codingoptional mechanical coding via front socket
in international format without spaces