Baumer
Choose a subcategory:
Show all categories
Voltage supply | 5 VDC ±10 % 10...30 VDC 4.5...30 VDC |
Consumption typ. | 80 mA (5 VDC, w/o load) 180 mA (4.5 VDC, w/o load) 60 mA (24 VDC, w/o load) |
Pulses per revolution | 10...5000 |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption typ. | 60 mA (5 VDC, w/o load) 40 mA (24 VDC, w/o load) |
Pulses per revolution | 4096...320000 |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±5 % |
Consumption typ. | 100 mA (5 VDC, w/o load) |
Sinewave cycles per turn | 1000...5000 |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±10 % 10...30 VDC 4.5...30 VDC |
Consumption typ. | 80 mA (5 VDC, w/o load) 180 mA (4.5 VDC, w/o load) 60 mA (24 VDC, w/o load) |
Pulses per revolution | 10...5000 |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption typ. | 60 mA (5 VDC, w/o load) 40 mA (24 VDC, w/o load) |
Pulses per revolution | 4096...320000 |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±5 % |
Consumption typ. | 100 mA (5 VDC, w/o load) |
Sinewave cycles per turn | 1000...5000 |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption typ. | 60 mA (5 VDC, w/o load) 30 mA (24 VDC, w/o load) |
Pulses per revolution | 10...2048 |
Operating temperature | -20...+85 °C |
Encoder Case Diameter: 40 mm.
Encoder Case Diameter: 40 mm.
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption typ. | 80 mA (5 VDC, w/o load) 60 mA (24 VDC, w/o load) |
Pulses per revolution | 20...5000 |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±5 % |
Consumption typ. | 100 mA (5 VDC, w/o load) |
Sinewave cycles per turn | 1000...5000 |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption typ. | 80 mA (5 VDC, w/o load) 60 mA (24 VDC, w/o load) |
Pulses per revolution | 10000...320000 |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption typ. | 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) |
Initializing time typ. | 70 ms after power on |
Operating temperature | -20...+85 °C |
Inputs | SSI clock Zero setting input |
Voltage supply | 10...30 VDC |
Consumption typ. | 100 mA (24 VDC, w/o load) |
Initializing time typ. | 170 ms after power on |
Operating temperature | -20...+85 °C |
Voltage supply | 10...30 VDC |
Consumption typ. | 100 mA (24 VDC, w/o load) |
Initializing time typ. | 170 ms after power on |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption typ. | 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) |
Initializing time typ. | 170 ms after power on |
Operating temperature | -20...+85 °C |
Inputs | SSI clock Zero setting input |
Voltage supply | 8...30 VDC |
Reverse polarity protection | Yes |
Short-circuit proof | Yes |
Operating temperature | -40...+85 °C |
Voltage supply | 10...30 VDC |
Consumption w/o load | ≤80 mA (24 VDC) |
Initializing time typ. | 500 ms after power on |
Operating temperature | -40...+85 °C (see general informations) |
Voltage supply | 10...30 VDC |
Consumption typ. | 100 mA (24 VDC, w/o load) |
Initializing time typ. | 500 ms after power on |
Operating temperature | -20...+65 °C |
Voltage supply | 10...30 VDC |
Consumption typ. | 100 mA (24 VDC, w/o load) |
Initializing time typ. | 170 ms after power on |
Operating temperature | -20...+85 °C |
Voltage supply | 10...30 VDC |
Consumption w/o load | ≤200 mA (24 VDC) |
Initializing time | ≤250 ms after power on |
Operating temperature | -40...+85 °C (see general informations) |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption w/o load | ≤150 mA (5 VDC) ≤60 mA (24 VDC) |
Initializing time typ. | 170 ms after power on |
Operating temperature | -40...+85 °C (see general informations) |
Inputs | SSI clock: Linereceiver RS422 Zero setting input |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption typ. | 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) |
Sensing method | Magnetic |
Operating temperature | -20...+85 °C |
Inputs | SSI clock Zero setting input |
Voltage supply | 10...30 VDC |
Consumption typ. | 100 mA (24 VDC, w/o load) |
Sensing method | Magnetic |
Operating temperature | -20...+85 °C |
Voltage supply | 10...30 VDC |
Consumption typ. | 100 mA (24 VDC, w/o load) |
Sensing method | Magnetic |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption typ. | 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) |
Sensing method | Magnetic |
Operating temperature | -20...+85 °C |
Inputs | SSI clock Zero setting input |
Voltage supply | 8...30 VDC |
Reverse polarity protection | Yes |
Short-circuit proof | Yes |
Operating temperature | -40...+85 °C |
Voltage supply | 10...30 VDC |
Consumption typ. | 50 mA (24 VDC, w/o load) |
Interface | CANopen® |
Operating temperature | -40...+65 °C |
Voltage supply | 10...30 VDC |
Consumption typ. | 50 mA (24 VDC, w/o load) |
Initializing time | ≤170 ms after power on |
Operating temperature | -40...+85 °C |
Inputs | SSI clock Zero setting input |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption typ. | 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) |
Initializing time typ. | 70 ms after power on |
Operating temperature | -20...+85 °C |
Inputs | SSI clock Zero setting input |