repeat accuracy< 0,001 mm
activating force75 cN
mech. pre-run / overrun- / 0,6 mm approx.
output circuitPNP make function (NO)
operating temperature-20 ... +75 °C
repeat accuracy< 0,001 mm
activating force75 cN
mech. pre-run / overrun- / 0,6 mm approx.
output circuitPNP make function (NO)
operating temperature-20 ... +75 °C
repeat accuracy< 0,001 mm
activating force75 cN
mech. pre-run / overrun- / 1,5 mm approx.
output circuitbreak function (NC) mechanical
operating temperature-20 ... +75 °C
repeat accuracy< 0,001 mm
activating force75 cN
mech. pre-run / overrun- / 1,5 mm approx.
output circuitNPN make function (NO)
operating temperature-20 ... +75 °C
repeat accuracy< 0,001 mm
activating force75 cN
mech. pre-run / overrun- / 1,5 mm approx.
output circuitPNP make function (NO)
operating temperature-20 ... +75 °C
repeat accuracy< 0,001 mm
activating force75 cN
mech. pre-run / overrun- / 1,5 mm approx.
output circuitPNP make function (NO)
operating temperature-20 ... +75 °C
measuring distance Sd16 ... 26 mm
adjustmentTeach-in: button / external
Teach-in range min.> 1 mm
operating temperature0 ... +50 °C

Distance sensors OADM 12I6460/S35A with 16 ... 120 mm, 0 ... +50 °C, 100 mA

measuring distance Sd16 ... 120 mm
adjustmentTeach-in: button / external
Teach-in range min.> 2 mm
operating temperature0 ... +50 °C
measuring distance Sd16 ... 26 mm
adjustmentTeach-in: button / external
Teach-in range min.> 1 mm
operating temperature0 ... +50 °C
measuring distance Sd50 ... 350 mm
adjustmentTeach-in: button / external
Teach-in range min.> 5 mm
operating temperature0 ... +50 °C
measuring distance Sd50 ... 550 mm
adjustmentTeach-in: button / external
Teach-in range min.> 10 mm
operating temperature0 ... +50 °C
measuring distance Sd50 ... 550 mm
adjustmentTeach-in: button / external
Teach-in range min.> 10 mm
operating temperature0 ... +50 °C
measuring distance Sd50 ... 550 mm
adjustmentTeach-in: button / external
Teach-in range min.> 10 mm
operating temperature0 ... +50 °C
measuring distance Sd100 ... 200 mm
adjustmentTeach-in: button / external
Teach-in range min.> 5 mm
operating temperature0 ... +50 °C
  • output circuit: analog
  • operating temperature: 0 ... +50 °C
  • protection class: IP 67
measuring distance Sd30 ... 130 mm
adjustmentno
wave length650 nm
operating temperature0 ... +50 °C
measuring distance Sd30 ... 70 mm
adjustmentTeach-in: button / external
Teach-in range min.> 2 mm
operating temperature0 ... +50 °C
measuring distance Sd30 ... 130 mm
adjustmentTeach-in: button / external
Teach-in range min.> 3 mm
operating temperature0 ... +50 °C
measuring distance Sd100 ... 600 mm
adjustmentTeach-in: button / external
Teach-in range min.> 10 mm
operating temperature0 ... +50 °C
measuring distance Sd200 ... 1000 mm
adjustmentTeach-in: button / external
Teach-in range min.> 20 mm
operating temperature0 ... +50 °C
measuring distance Sd30 ... 70 mm
adjustmentTeach-in: button / external
Teach-in range min.> 2 mm
operating temperature0 ... +50 °C
measuring distance Sd200 ... 1000 mm
adjustmentTeach-in: button / external
Teach-in range min.> 20 mm
operating temperature-20 ... +60 °C
measuring distance Sd200 ... 1000 mm
adjustmentTeach-in: button / external
Teach-in range min.> 10 mm
operating temperature0 ... +50 °C
measuring distance Sd50 ... 300 mm
special typeWashdown design
adjustmentexternal
operating temperature0 ... +50 °C
typetolerance analysis
sensing distance Tw16 ... 120 mm
Teach-in range min.> 0,4 mm
operating temperature0 ... +50 °C
typewindow analysis
sensing distance Tw16 ... 120 mm
Teach-in range min.> 0,4 mm
operating temperature0 ... +50 °C
  • Intiutive OLED display
  • Programmable input configurations
  • Crosstalk rejection between two sensors without a wire
  • Six AUTOSET modes
  • Advanced remote programming
typemeasuring mode: edges, center, width, gap
versionPosCon 3D
measuring range (width)75 ... 125 mm
output circuitanalog and RS 485