mounting type | quasi-flush |
special type | full metal housing (DuroProx) high temperature |
nominal sensing distance Sn | 6 mm |
output circuit | NPN make function (NO) |
operating temperature | -25 ... +100 °C |
mounting type | flush |
special type | high temperature |
nominal sensing distance Sn | 1,5 mm |
output circuit | PNP break function (NC) |
operating temperature | -25 ... +180 °C |
mounting type | flush |
nominal sensing distance Sn | 0,8 mm |
hysteresis | 2 ... 20 % of Sr |
output circuit | NPN break function (NC) |
operating temperature | -25 ... +75 °C |
mounting type | flush |
special type | high pressure |
nominal sensing distance Sn | 2 mm |
output circuit | PNP make function (NO) |
operating temperature | -25 ... +80 °C |
mounting type | flush |
special type | high pressure |
nominal sensing distance Sn | 2 mm |
output circuit | PNP make function (NO) |
operating temperature | -25 ... +80 °C |
version | full metal |
sensor type | differential hall sensor |
working distance max. | <1 mm="" module="" 1="" 2="" 5="" 3="" td=""> |
operating temperature | -40 ... +120 °C |
mounting type | flush |
special type | inductive code reader |
nominal sensing distance Sn | 2 mm |
output circuit | PNP make function (NO) |
operating temperature | 0 ... +60 °C |
mounting type | flush |
special type | inductive code reader |
nominal sensing distance Sn | 2 mm |
output circuit | PNP make function (NO) |
operating temperature | 0 ... +60 °C |
mounting type | quasi-flush |
measuring speed | < 1 mm / ms |
measuring distance Sd | 0,5 ... 1,5 mm |
output circuit | current output |
operating temperature | 0 ... +60 °C |
mounting type | quasi-flush |
special type | linearized |
measuring distance Sd | 0 ... 6 mm |
output circuit | current output |
operating temperature | -25 ... +75 °C (Vs = 8 ... 30 VDC) -25 ... +60 °C (Vs = 8 ... 36 VDC) |
mounting type | quasi-flush |
special type | linearized |
measuring distance Sd | 0 ... 10 mm |
output circuit | voltage output / PNP |
operating temperature | -10 ... +70 °C |
mounting type | flush |
measuring distance Sd | 0 ... 4 mm |
resolution | < 0,001 mm |
output circuit | voltage - / current output |
operating temperature | -10 ... +70 °C |
mounting type | flush |
measuring distance Sd | 0 ... 4 mm |
resolution | < 0,001 mm |
output circuit | voltage - / current output |
operating temperature | -10 ... +70 °C |
mounting type | flush |
measuring distance Sd | 0 ... 2 mm |
resolution | < 0,001 mm (stat.) < 0,005 mm (dynam.) |
output circuit | voltage output |
operating temperature | -10 ... +70 °C |
mounting type | quasi-flush |
special type | Outdoor design |
measuring distance Sd | 0 ... 8 mm |
output circuit | current output |
operating temperature | -40 ... +70 °C |
mounting type | quasi-flush |
special type | 2 adjust. switching points linearized |
measuring distance Sd | 0 ... 16 mm |
output circuit | voltage output / PNP |
operating temperature | -10 ... +70 °C |
mounting type | quasi-flush |
special type | Outdoor design Washdown design |
measuring distance Sd | 0 ... 7 mm |
output circuit | current output |
operating temperature | -40 ... +70 °C |
- Current output
- Flylead Connector PUR M8, L=200 mm
- -40 ... 85 В°C
- IP 67
- Please order magnet separately
- Current output
- Cable PUR 3 x 0.25, 2 m
- -40 ... 85 В°C
- IP 67
- Please order magnet separately
- Voltage output
- Cable PUR 3 x 0.25, 2 m
- -40 ... 85 В°C
- IP 67
- Please order magnet separately
version | full metal |
sensor type | differential hall sensor |
working distance max. | 1,6 mm (module 1,5) |
operating temperature | -40 ... +120 °C |
version | full metal |
sensor type | differential hall sensor |
working distance max. | 2 mm (module 2) |
operating temperature | -40 ... +120 °C |
version | full metal |
sensor type | differential hall sensor |
working distance max. | 2,2 mm (module 2,5) |
operating temperature | -40 ... +120 °C |
repeat accuracy | < 0,001 mm |
activating force | 100 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |
repeat accuracy | < 0,001 mm |
activating force | 250 cN |
mech. pre-run / overrun | 1 mm / 1 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |
repeat accuracy | < 0,001 mm |
activating force | 75 cN |
mech. pre-run / overrun | - / 0,8 ... 1,5 mm approx. |
output circuit | NPN make function (NO) |
operating temperature | -20 ... +75 °C |
repeat accuracy | < 0,001 mm |
activating force | 75 cN |
mech. pre-run / overrun | - / 0,8 ... 1,5 mm approx. |
output circuit | PNP make function (NO) |
operating temperature | -20 ... +75 °C |
repeat accuracy | < 0,001 mm |
activating force | 30 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | break function (NC) mechanical |
operating temperature | -20 ... +75 °C |
repeat accuracy | < 0,001 mm |
activating force | 75 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | NPN make function (NO) |
operating temperature | -20 ... +75 °C |
repeat accuracy | < 0,001 mm |
activating force | 75 cN |
mech. pre-run / overrun | - / 1,5 mm approx. |
output circuit | NPN make function (NO) |
operating temperature | -20 ... +75 °C |