Baumer

Voltage supply10...30 VDC
Consumption typ.50 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Interface12 parallel outputs
Operating temperature-20...+85 °C
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption w/o load≤150 mA (5 VDC)
≤60 mA (24 VDC)
Initializing time typ.170 ms after power on
Operating temperature-40...+85 °C (see general informations)
InputsSSI clock: Linereceiver RS422
Zero setting input
Baumer BNIV
Price on Request
One click request
Voltage supply4.75...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Pulses per revolution100...25000
Operating temperature-20...+85 °C
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.30 mA (5 VDC, w/o load)
15 mA (24 VDC, w/o load)
Pulses per revolution64...2048
Operating temperature-20...+85 °C
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.30 mA (5 VDC, w/o load)
15 mA (24 VDC, w/o load)
Pulses per revolution64...2048
Operating temperature-20...+85 °C
Voltage supply5 VDC ±10 %
20...28 VDC
Consumption typ.25 mA (5 VDC, w/o load)
30 mA (24 VDC, w/o load)
Pulses per revolution2...1024
Operating temperature-20...+85 °C (only 5 VDC)
-20...+65 °C
Voltage supply5 VDC ±10 %
20...28 VDC
Consumption typ.25 mA (5 VDC, w/o load)
30 mA (24 VDC, w/o load)
Pulses per revolution2...1024
Operating temperature-20...+85 °C
-20...+65 °C
Voltage supply5 VDC ±10 %
20...28 VDC
Consumption typ.25 mA (5 VDC, w/o load)
30 mA (24 VDC, w/o load)
Pulses per revolution2...1024
Operating temperature-40...+85 °C (only 5 VDC)
-40...+65 °C
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.30 mA (5 VDC, w/o load)
15 mA (24 VDC, w/o load)
Pulses per revolution64...2048
Operating temperature-20...+85 °C
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.30 mA (5 VDC, w/o load)
15 mA (24 VDC, w/o load)
Pulses per revolution64...2048
Operating temperature-20...+85 °C
special typesensor for high temperatures
nominal sensing distance Sn15 mm
nominal sensing distance Sn adjustable4 ... 15 mm
output circuitPNP make function (NO)
operating temperature-40 ... +200 °C
special typesensor for high temperatures
nominal sensing distance Sn15 mm
nominal sensing distance Sn adjustable4 ... 15 mm
output circuitPNP break function (NC)
operating temperature-40 ... +200 °C
nominal sensing distance Sn0,5 mm
mounting typenon-flush
GND electrodeno
output circuitNPN make function (NO)
operating temperature0 ... +70 °C
special typeliquid level sensor for wastewater
nominal sensing distance Sn0,1 mm
mounting typenon-flush
output circuitNPN make function (NO)
operating temperature0 ... +50 °C
special typeliquid level sensor for wastewater
nominal sensing distance Sn0,1 mm
mounting typenon-flush
output circuitNPN make function (NO)
operating temperature0 ... +50 °C
nominal sensing distance Sn0,5 mm
mounting typenon-flush
GND electrodeno
output circuitNPN break function (NC)
operating temperature0 ... +70 °C
special typeliquid level sensor for wastewater
nominal sensing distance Sn0,1 mm
mounting typenon-flush
output circuitNPN break function (NC)
operating temperature0 ... +50 °C
special typeliquid level sensor for wastewater
nominal sensing distance Sn0,1 mm
mounting typenon-flush
output circuitNPN break function (NC)
operating temperature0 ... +50 °C
nominal sensing distance Sn0,5 mm
mounting typenon-flush
GND electrodeno
output circuitPNP make function (NO)
operating temperature0 ... +70 °C
special typeliquid level sensor for wastewater
nominal sensing distance Sn0,1 mm
mounting typenon-flush
output circuitPNP make function (NO)
operating temperature0 ... +50 °C
special typeliquid level sensor for wastewater
nominal sensing distance Sn0,1 mm
mounting typenon-flush
output circuitPNP make function (NO)
operating temperature0 ... +50 °C
nominal sensing distance Sn0,5 mm
mounting typenon-flush
GND electrodeno
output circuitPNP break function (NC)
operating temperature0 ... +70 °C
special typeliquid level sensor for wastewater
nominal sensing distance Sn0,1 mm
mounting typenon-flush
output circuitPNP break function (NC)
operating temperature0 ... +50 °C
special typeliquid level sensor for wastewater
nominal sensing distance Sn0,1 mm
mounting typenon-flush
output circuitPNP break function (NC)
operating temperature0 ... +50 °C
nominal sensing distance Sn5 mm
mounting typenon-flush
GND electrodeno
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C


in international format without spaces