Baumer
Choose a subcategory:
Show all categories
measuring distance Sd | 0 ... 120 mm |
optimum operating distance | 70 mm |
object speed | < 5 m/sec |
operating temperature | 0 ... +50 °C |
measuring distance Sd | 0 ... 90 mm |
optimum operating distance | 70 mm |
counting rate | < 3000000 copies/h |
output circuit | opto isolated |
operating temperature | 0 ... +50 °C |
measuring distance Sd | 0 ... 120 mm |
optimum operating distance | 100 mm |
counting rate | < 3000000 copies/h |
output circuit | opto isolated |
operating temperature | 0 ... +50 °C |
measuring distance Sd | 0 ... 90 mm |
optimum operating distance | 70 mm |
counting rate | < 3000000 copies/h |
operating temperature | 0 ... +50 °C |
measuring distance Sd | 0 ... 120 mm |
optimum operating distance | 100 mm |
counting rate | < 3000000 copies/h |
operating temperature | 0 ... +50 °C |
particular characteristics | array (fine light barrier) |
type | through beam sensor |
actual range Sb | 790 mm |
operating temperature | -30 ... +70 °C |
particular characteristics | array (fine light barrier) |
type | through beam sensor |
actual range Sb | 790 mm |
operating temperature | -30 ... +70 °C |
particular characteristics | side view small sensing head smooth sensing head without thread |
type | through beam sensor |
actual range Sb | 165 mm |
operating temperature | -30 ... +70 °C |
particular characteristics | ultra flexible |
type | through beam sensor |
actual range Sb | 140 mm |
operating temperature | -30 ... +70 °C |
particular characteristics | ultra flexible |
type | Diffuse sensors |
sensing distance Tw | 1 ... 210 mm |
operating temperature | -30 ... +70 °C |
type | Diffuse sensors (liquid level sensor) |
measurement type | contact with medium |
response time / release time | 0,05 ... 5 ms |
operating temperature | -30 ... +105 °C |
version | 2 outputs |
actual range Sb (FSE 200C1002) | 1200 mm |
sensing distance Tw (FUE 200C1003) | 300 mm |
operating temperature | -20 ... +55 °C |
version | master |
actual range Sb (FSE 200C1002) | 1200 mm |
sensing distance Tw (FUE 200C1003) | 300 mm |
operating temperature | -20 ... +55 °C |
actual range Sb (FSE 200C1002) | 1200 mm |
sensing distance Tw (FUE 200C1003) | 300 mm |
light source | pulsed red LED |
operating temperature | -20 ... +55 °C |
version | 2 outputs |
actual range Sb (FSE 200C1002) | 1200 mm |
sensing distance Tw (FUE 200C1003) | 300 mm |
operating temperature | -20 ... +55 °C |
version | master |
actual range Sb (FSE 200C1002) | 1200 mm |
sensing distance Tw (FUE 200C1003) | 300 mm |
operating temperature | -20 ... +55 °C |
actual range Sb (FSE 200C1002) | 1200 mm |
sensing distance Tw (FUE 200C1003) | 300 mm |
light source | pulsed red LED |
operating temperature | -20 ... +55 °C |
version | slave |
actual range Sb (FSE 200C1002) | 1200 mm |
sensing distance Tw (FUE 200C1003) | 300 mm |
operating temperature | -20 ... +55 °C |
actual range Sb (FSE 200C1002) | 320 mm |
sensing distance Tw (FUE 200C1003) | 90 mm |
light source | pulsed red LED |
operating temperature | -25 ... +55 °C |
version | integrated alarm output |
actual range Sb (FSE 200C1002) | 320 mm |
sensing distance Tw (FUE 200C1003) | 90 mm |
operating temperature | -25 ... +55 °C |
version | integrated alarm output |
actual range Sb (FSE 200C1002) | 320 mm |
sensing distance Tw (FUE 200C1003) | 90 mm |
operating temperature | -25 ... +55 °C |
version | integrated alarm output |
actual range Sb (FSE 200C1002) | 320 mm |
sensing distance Tw (FUE 200C1003) | 90 mm |
operating temperature | -25 ... +55 °C |
actual range Sb | 1200 mm |
sensing distance Tw | 240 mm |
light source | pulsed infrared diode |
operating temperature | -25 ... +65 °C |
type | intensity difference |
light source | pulsed infrared diode |
sensing distance Tw | 300 ... 1500 mm |
operating temperature | 0 ... +65 °C |
type | intensity difference |
light source | pulsed infrared diode |
sensing distance Tw | 100 ... 700 mm |
operating temperature | 0 ... +65 °C |
mounting type | flush |
special type | with banking screw |
nominal sensing distance Sn | 0,4 mm |
output circuit | PNP make function (NO) |
operating temperature | -25 ... +75 °C |
mounting type | flush |
special type | with banking screw |
nominal sensing distance Sn | 1,2 mm |
output circuit | NPN make function (NO) |
operating temperature | -25 ... +75 °C |
mounting type | quasi-flush |
special type | full metal housing (DuroProx) high temperature |
nominal sensing distance Sn | 2 mm |
output circuit | NPN make function (NO) |
operating temperature | -25 ... +100 °C |
mounting type | quasi-flush |
special type | full metal housing (DuroProx) high temperature |
nominal sensing distance Sn | 2 mm |
output circuit | NPN break function (NC) |
operating temperature | -25 ... +100 °C |
mounting type | quasi-flush |
special type | full metal housing (DuroProx) high temperature |
nominal sensing distance Sn | 2 mm |
output circuit | NPN make function (NO) |
operating temperature | -25 ... +100 °C |