Endress+Hauser Flow Meters

Proline Prowirl F 200 vortex flowmeter

Proline Prowirl F 200 vortex flowmeter

Proline Prowirl F 200 Vortex flowmeter

Proline Prowirl R 200 Vortex flowmeter

Proline Promass F 300 Coriolis flowmeter

Smartec CLD132 compact conductivity transmitter

Smartec CLD134 compact conductivity transmitter

Smartec CLD134 compact conductivity transmitter

Smartec CLD18 compact conductivity transmitter

Picomag, DMA15 Electromagnetic flowmeter

Time-of-Flight ultrasonic level measurement

Time-of-Flight ultrasonic level measurement

Ultrasonic measurement Time-of-Flight

Capacitance Point level detection Solicap FTI56

Proline Promag P 300 Electromagnetic flowmeter

Compact temperature sensor

Compact temperature sensor


  • 200 µS/cm to 1000 mS/cm
  • Cell constant c: 11.0 1/cm

Max. measurement error

Mass flow: В±0.5 % of batch

Measuring range

0 to 150 kg/min (0 to 330 lb/min)

Medium temperature range

50 to +125 В°C (58 to +257 В°F)

Max. process pressure

350 bar (5080 psi)

Wetted materials

Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316)

Coriolis flowmeter

Max. measurement error

Mass flow: В±0.5 % of batch

Measuring range

0 to 150 kg/min (0 to 330 lb/min)

Medium temperature range

50 to +125 В°C (58 to +257 В°F)

Max. process pressure

350 bar (5080 psi)

Wetted materials

Mesuring tube: 1.4435 (316L)
Connection: 1.4404 (316/316L)

Max. measurement error

Mass flow: В±0.5 % of batch

Measuring range

0 to 150 kg/min (0 to 330 lb/min)

Medium temperature range

50 to +150 В°C (58 to +302 В°F)

Max. process pressure

350 bar (5080 psi)

Wetted materials

Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316)

Max. measurement error

Mass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.5 %
Density (liquid): В±0.0005 g/cm3

Measuring range

0 to 1000 kg/h (0 to 37 lb/min)

Medium temperature range

50 to +200 В°C (58 to +392 В°F)

Max. process pressure

PN 40, Class 300, 10K, 400 bar (5800 psi)

Wetted materials

Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)

Max. measurement error

Mass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.5 %
Density (liquid): В±0.0005 g/cm3

Measuring range

0 to 1000 kg/h (0 to 37 lb/min)

Medium temperature range

50 to +200 В°C (58 to +392 В°F)

Max. process pressure

PN 40, Class 300, 10K, 400 bar (5800 psi)

Wetted materials

Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)

Differential pressure sensor
Differential pressure sensor
Differential pressure sensor
Differential pressure sensor
Differential pressure sensor