Endress+Hauser Flow Meters

Ultrasonic flow meter

Max. measurement error

+/-2.0 %

Measuring range

0....452'389 m3/h

Medium temperature range

DN 15...65
-40...+150В°C
(-40...+302В°F)
DN 50...300
-40...+170В°C
(-40...+338В°F)
DN 100...4000
-40...+80В°C
(-40...+176В°F)

Max. process pressure

No limit

Ultrasonic flow meter

Max. measurement error

Volume flow:
В±3% o.r. for DN15
В±2% o.r. for DN25 to 200
В±2% o.r. above DN200

Measuring range

0.3 to 10 m/s (1 to 33 ft/s)

Medium temperature range

Clamp-on: 20 to +80 В°C (4 to +176 В°F)
Insertion version: 40 to +80 В°C

Max. process pressure

N/A

Wetted materials

Clamp on system:
Sensor holder 1.4308/CF-8
Sensor housing 1.4301/304
Strapping bands 1.4301/304

Max. measurement error

Volume flow (standard):
‐ ±1.5 % o.r. for 3 to 30 m/s (9.84 to 98.4 ft/s)
‐ ±3 % o.r. for 1 to 3 m/s (3.28 to 9.84 ft/s)
Volume flow (option):
‐ ±0.1 % o.f.s. for 0.3 to 1 m/s (0.98 to 3.28 ft/s)
‐ ±1.5 % o.r. for 1 to 30 m/s (3.28 to 98.4 ft/s)

Measuring range

Standard: 1 to 30 m/s (3.28 to 98.4 ft/s)
Option: 0.3 to 30 m/s (0.98 to 98.4 ft/s)

Medium temperature range

0 to +80 В°C (+32 to +176 В°F)

Max. process pressure

11 bar a (159 psi a)

Wetted materials

Sensor: 1.4404/1.4435 (316L)
Transducer: HNBR
Temperature sensor (option): AFM 34

Max. measurement error

Volume flow:
- В± 0.5 % o.r. В± 0.02% o.f.s. for 0.5 to 10 m/s (1.6 to 33 ft/s)
- В± 0.07 % o.f.s. for flow velocities < 0.5 m/s (1.64 ft/s)

Measuring range

0.025 to 5 m/s (0.02 to 16.4 ft/s)
0 to 6360 dm3/min (0 to 1680 gal/min)

Medium temperature range

0 to 150В° (17.8 to 302 В°F)

Max. process pressure

PN 25 / ASME Cl. 150

Wetted materials

Measuring tube: 1.4301 (F304)
Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105

Max. measurement error

Volume flow (standard):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Volume flow (optional calibration):
‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (standard):
‐ ±1.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (optional calibration):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Sound Velocity: В±0.2 % o.r.

Measuring range

Gas: 0.3 m/s to 40 m/s

Medium temperature range

-50 to 150 В°C (-58 to +302В°F)
-50 to 100 В°C (-58 to +212В°F) with integrated pressure cell

Max. process pressure

0.7 to 101 bar a (10.15 to 1464.88 psi a)

Wetted materials

Measuring tube: 1.4408/1.4409 (CF3M)
Transducer: 1.4404 (316, 316L), Titan Grade 2

Max. measurement error

Volume flow (standard):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Volume flow (optional calibration):
‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (standard):
‐ ±1.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (optional calibration):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Sound Velocity: В±0.2 % o.r.

Measuring range

Gas: 0.3 m/s to 40 m/s

Medium temperature range

-50 to 150 В°C (-58 to +302В°F)
-50 to 100 В°C (-58 to +212В°F) with integrated pressure cell

Max. process pressure

0.7 to 101 bar a (10.15 to 1464.88 psi a)

Wetted materials

Measuring tube: 1.4408/1.4409 (CF3M)
Transducer: 1.4404 (316, 316L, Titan Grade 2

Max. measurement error

Volume flow: В±2% o.r. above DN200

Measuring range

0 to 15 m/s (0 to 50 ft/s)

Medium temperature range

40 to +80 В°C (40 to +176 В°F)

Max. process pressure

N/A

Wetted materials

Insertion system:
Sensor holder 1.4301 (304), 1.4404 (316L)
Sensor housing 1.4301 (304), 1.4404 (316L)

Max. measurement error

Volume flow:
В±3% o.r. for DN 15
В±2% o.r. for DN 25 to DN 200
В±2% o.r. above DN 200

Measuring range

0 to 15 m/s (0 to 50 ft/s)

Medium temperature range

DN 15 to 65 (ВЅto 2ВЅ"): 40 to +150В°C (40 +302 В°F)
DN 50 to 4000 (2 to 160"): 40 to +170В°C (40 to +338 В°F)

Max. process pressure

N/A

Max. measurement error

Volume flow:
В±3% o.r. for DN15
В±2% o.r. for DN25 to 200
В±2% o.r. above DN200

Measuring range

0 to 15 m/s (0 to 50 ft/s)

Medium temperature range

40 to +130 В°C (40 to +266 В°F)

Max. process pressure

N/A

Max. measurement error

Volume flow (liquid): В±0.75 %
Volume flow (steam, gas): В±1.00 %
Mass flow (liquid): В±0.85%
Mass flow (steam, gas): В±1.7 %

Measuring range

Liquid: 0.99 to 545 mВі/h (0.58 to 321 ftВі/min)
depending on medium: water with 1 bar a, 20 В°C (14.5 psi a, 68В° F)
Steam, gas: 13.8 to 7262 mВі/h (8.12 to 4274 ftВі/min)
depending on medium: steam with 180 В°C, 10 bar a (356 В°F, 145 psi a); air
with 25 В°C, 4.4 bar a (77 В°F, 63.8 psi a)

Medium temperature range

40 to +400 В°C (40 to +752 В°F)

Max. process pressure

Class 900

Wetted materials

Measuring tube: SA‐106 grade B/SA‐333 grade 6
Bluff body, inspection ports: SA‐105/SA‐350 LF2
DSC sensor: UNS N07718 similar to Alloy 718, 2.4668
Connection: SA‐105/SA‐350 LF2

Max. measurement error

Volume flow (liquid): В±0.75 %
Volume flow (steam, gas): В±1.00 %
Mass flow (liquid): В±0.85%
Mass flow (steam, gas): В±1.7 %

Measuring range

Liquid: 0.16 to 625 mВі/h (0.09 to 368 ftВі/min)
depending on medium: water with 1 bar a, 20 В°C (14.5 psi a, 68В° F)
Steam, gas: 2 to 8342 mВі/h (1.18 to 4910 ftВі/min)
depending on medium: steam with 180 В°C, 10 bar a (356 В°F, 145 psi a); air with 25 В°C, 4.4 bar a (77 В°F, 63.8 psi a)

Medium temperature range

Standard: 40 to +260 В°C (40 to +500 В°F)
High/low temperature (option): 200 to +400 В°C (328 to +752 В°F)
High/low temperature (on request): 200 to +450 В°C (328 to +842 В°F)

Max. process pressure

PN 40, Class 300, 20K

Wetted materials

Measuring tube: 1.4408 (C3FM)
DSC sensor: 1.4435 (316/316L)

Vortex flowmeter

Max. measurement error

Volume flow (liquid): В±0.75 %
Volume flow (optional): В±0.65 %
Volume flow (optional): В±0.65 %
Volume flow (steam, gas): В±1.00 %
Mass flow (saturated steam): В±1.7% (temperature compensated); В±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): В±1.5 (temperature/pressure compensated); В±1.7% (temperature compensated + external pressure compensation)
Mass flow (liquid): В±0.85%

Max. measurement error

Volume flow (liquid): В±0.75 %
Volume flow (steam, gas): В±1.00 %
Mass flow (saturated steam): В±1.7% (temperature compensated); В±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): В±1.5 (temperature/pressure compensated); В±1.7% (temperature compensated + external pressure compensation)
Mass flow (liquid): В±0.85%

Measuring range

Liquid: 0.1 to 1700 mВі/h (0.061 to 1000 ftВі/min)
depending on medium: water with 1 bar a, 20 В°C (14.5 psi a, 68В° F)
Steam, gas: 0.52 to 22000 mВі/h (0.31 to 13000 ftВі/min)
depending on medium: steam with 180 В°C, 10 bar a (356 В°F, 145 psi a); air with 25 В°C, 4.4 bar a (77 В°F, 63.8 psi a)

Medium temperature range

Standard: 40 to +260 В°C (40 to +500 В°F)
High/low temperature (option): 200 to +400 В°C (328 to +752 В°F)

Max. process pressure

PN 250, Class 1500, 40K

Wetted materials

Measuring tube: 1.4408 (CF3M)
DSC sensor: UNS N07718 similar to Alloy 718, 2.4668
Process connection: 1.4404/F316/F316L

Max. measurement error

Volume flow (liquid): В±0.75 %
Volume flow (steam, gas): В±1.00 %
Mass flow (saturated steam): В±1.7% (temperature compensated); В±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): В±1.5 (temperature/pressure compensated); В±1.7% (temperature compensated + external pressure compensation)
Mass flow (liquid): В±0.85%

Measuring range

Liquid: 0.1 to 540 mВі/h (0.061 to 320 ftВі/min)
depending on medium: water with 1 bar a, 20 В°C (14.5 psi a, 68В° F)
Steam, gas: 0.52 to 7300 mВі/h (0.31 to 4300 ftВі/min)
depending on medium: steam with 180 В°C, 10 bar a (356 В°F, 145 psi a); air with 25 В°C, 4.4 bar a (77 В°F, 63.8 psi a)

Medium temperature range

Standard: 40 to +260 В°C (40 to +500 В°F)
High/low temperature (option): 200 to +400 В°C (328 to +752 В°F)
High/low temperature (on request): 200 to +450 В°C (328 to +842 В°F)

Max. process pressure

PN 40, Class 300, 20K

Wetted materials

Measuring tube: 1.4408 (CF3M)
DSC sensor: 1.4404/F316/F316L
Process connection: 1.4404/F316/F316L

Thermal Mass Flow Meter

Max. measurement error

Gas: 1.5% o.r. (10 to 100% o.f.s.), 0.15% o.f.s. (1 to 10% o.f.s.)

Thermal Mass Flow Meter

Max. measurement error

Gas: 1.5% o.r. (10 to 100% o.f.s.), 0.15% o.f.s. (1 to 10% o.f.s.)

Thermal Mass Flow Meter

Max. measurement error

3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature "Calibration flow")

Thermal Mass Flow Meter

Max. measurement error

3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature "Calibration flow")

Max. measurement error

Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)

Measuring range

0.5 to 3750 kg/h (1.1 to 8250 lb/h)

Medium temperature range

-40 В°C to +180В°C (-40 В°F to +356 В°F)

Max. process pressure

PN40 / Cl. 300 / 20K

Wetted materials

Measuring tubes
DN 15 to 50 (ВЅ to 2"): stainless cast steel, CF3M/1.4408
DN 65 to 100 (2ВЅ to 4"): stainless steel, 1.4404 (316/316L)
Process connections
Flange connections
Stainless steel, 1.4404 (F316/F316L)
Threaded connections
Stainless steel, 1.4404 (316/316L)
Sensing element
Unidirectional
Stainless steel, 1.4404 (316/316L)
Alloy C22, 2.4602 (UNS N06022);
Bidirectional
Stainless steel, 1.4404 (316/316L)
Reverse flow detection
Stainless steel, 1.4404 (316/316L)

Max. measurement error

Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)

Measuring range

0.5 to 3750 kg/h (1.1 to 8250 lb/h)

Medium temperature range

-40 В°C to +180В°C (-40 В°F to +356 В°F)

Max. process pressure

PN40 / Cl. 300 / 20K

Wetted materials

Measuring tubes
DN 15 to 50 (ВЅ to 2"): stainless cast steel, CF3M/1.4408
DN 65 to 100 (2ВЅ to 4"): stainless steel, 1.4404 (316/316L)
Process connections
Flange connections
Stainless steel, 1.4404 (F316/F316L)
Threaded connections
Stainless steel, 1.4404 (316/316L)
Sensing element
Unidirectional
Stainless steel, 1.4404 (316/316L)
Alloy C22, 2.4602 (UNS N06022);
Bidirectional
Stainless steel, 1.4404 (316/316L)
Reverse flow detection
Stainless steel, 1.4404 (316/316L)

Max. measurement error

Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)

Measuring range

20 to 733501 kg/h (44 to 1669340 lb/h)

Medium temperature range

-40 В°C to +180В°C (-40 В°F to +356В°F)

Max. process pressure

-0.5 to 20 bar_g (-7.25 to 290 psi_g)

Wetted materials

Materials for insertion tube
Stainless steel, 1.4404 (316/316L)
Process connections, process coupling
Stainless steel, 1.4404 (316/316L)
Sensing element
Unidirectional
Stainless steel, 1.4404 (316/316L)
Alloy C22, 2.4602 (UNS N06022);
Bidirectional
Stainless steel, 1.4404 (316/316L)
Reverse flow detection
Stainless steel, 1.4404 (316/316L)
Clamping rings
PEEK
PVDF
1.4404 (316/316L)
Flat ring seal
EPDM
FKM

Max. measurement error

Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)

Measuring range

20 to 733501 kg/h (44 to 1669340 lb/h)

Medium temperature range

-40 В°C to +180В°C (-40 В°F to +356В°F)

Max. process pressure

-0.5 to 20 bar_g (-7.25 to 290 psi_g)

Wetted materials

Materials for insertion tube
Stainless steel, 1.4404 (316/316L)
Process connections, process coupling
Stainless steel, 1.4404 (316/316L)
Sensing element
Unidirectional
Stainless steel, 1.4404 (316/316L)
Alloy C22, 2.4602 (UNS N06022);
Bidirectional
Stainless steel, 1.4404 (316/316L)
Reverse flow detection
Stainless steel, 1.4404 (316/316L)
Clamping rings
PEEK
PVDF
1.4404 (316/316L)
Flat ring seal
EPDM
FKM

Max. measurement error

Flow: В±5 % o.f.s.

Measuring range

226 to 14 100 000 l/h (60 to 3 730 000 gal/h)
(under reference conditions)

Medium temperature range

20 to +100 В°C (4 to +212 В°F)

Max. process pressure

PN 40

Wetted materials

Transducer: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Insertion tube: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection:
‐ Compression fitting: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Threadolet: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Clamping ferrule: PEEK 450G; 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Tri‐Clamp; DN40 DIN 11851, DN50 DIN 11851; DN40 DIN 11864‐1A, DN50 DIN 11864‐1A: 1.4404 (316L)

Electromagnetic flowmeter

Electromagnetic flowmeter