Endress+Hauser Flow Meters

Max. measurement error

Mass flow (liquid): В±0.15 % (standard), В±0.10 % (option)
Volume flow (liquid): В±0.15 %
Mass flow (gas): В±0.50 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 180 000 kg/h (0 to 6615 lb/min)

Medium temperature range

40 to +150 В°C (40 to +302 В°F)

Max. process pressure

PN 100, Class 600, 63K

Wetted materials

Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)

Max. measurement error

Mass flow (liquid): В±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.25 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 2 200 000 kg/h (0 to 80 840 lb/min)

Medium temperature range

Standard: 50 to +150 В°C (58 to +302 В°F)
Option: 50 to +240 В°C (58...+464 В°F)

Max. process pressure

PN 100, Class 600, 63K

Wetted materials

Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)

Max. measurement error

Mass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.25 % Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 70 000 kg/h (0 to 2570 lb/min)

Medium temperature range

Standard: 50 to +150 В°C (58 to +302 В°F)
Option: 50 to +205 В°C (58 to +401 В°F)

Max. process pressure

PN 100, Class 600, 63K

Wetted materials

Measuring tube: 1.4539 (904L); 1.4404 ; Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)

Max. measurement error

Mass flow (liquid): В±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.25 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 2 200 000 kg/h (0 to 80 840 lb/min)

Medium temperature range

Standard: 50 to +150 В°C (58...+302 В°F)
Option: 50 to +240 В°C (58...+464 В°F)
High temperatur option: 50 to +350 В°C (58...+662 В°F)
Option: 196 to +150 В°C (320 to +302 В°F)

Max. process pressure

PN 100, Class 600, 63K

Wetted materials

Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304)

Max. measurement error

Mass flow (liquid): В±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.25 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 2 200 000 kg/h (0 to 80 840 lb/min)

Medium temperature range

Standard: 50 to +150 В°C (58...+302 В°F)
Option: 50 to +240 В°C (58...+464 В°F)
High temperatur option: 50 to +350 В°C (58...+662 В°F)
Option: 196 to +150 В°C (320 to +302 В°F)

Max. process pressure

PN 100, Class 600, 63K

Wetted materials

Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304)

Max. measurement error

Mass flow (liquid): В±0.15 %
Volume flow (liquid): В±0.15 %
Mass flow (gas): В±0.75 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 18 000 kg/h (0 to 662 lb/min)

Medium temperature range

50 to +150 В°C (58 to +302 В°F)

Max. process pressure

350 bar (5080 psi)

Wetted materials

Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316/316L)

Max. measurement error

Mass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas, Tantalum only): В±0.5 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 70 000 kg/h (0 to 2570 lb/min)

Medium temperature range

Tantalum: 50 to +150 В°C (58 to +302 В°F)
Zirconium: 50 to +205 В°C (58 to +401 В°F)

Max. process pressure

PN 40, Class 300, 20K

Wetted materials

Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702)

Max. measurement error

Mass flow (liquid): В±0.10 %
Volume flow (liquid): В±0.10 %
Mass flow (gas, Tantalum only): В±0.50 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 70 000 kg/h (0 to 2570 lb/min)

Medium temperature range

Tantalum: 50 to +150 В°C (58 to +302 В°F)
Zirconium: 50 to +205 В°C (58 to +401 В°F)

Max. process pressure

PN 40, Class 300, 20K

Wetted materials

Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702)

Max. measurement error

Mass flow (liquid): В±0.10 %
Volume flow (liquid): В±0.10 %
Mass flow (gas, Tantalum only): В±0.50 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 70 000 kg/h (0 to 2570 lb/min)

Medium temperature range

Tantalum: 50 to +150 В°C (58 to +302 В°F)
Zirconium: 50 to +205 В°C (58 to +401 В°F)

Max. process pressure

PN 40, Class 300, 20K

Wetted materials

Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702)

Max. measurement error

Mass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.5 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 180 000 kg/h (0 to 6600 lb/min)

Medium temperature range

50 to +150 В°C (58 to +302 В°F)

Max. process pressure

PN 100, Class 600, 63K

Wetted materials

Measuring tube: Titanium grade 9
Connection: Titanium grade 2

Max. measurement error

Mass flow (liquid): В±0.10 %
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.50 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 180 000 kg/h (0 to 6600 lb/min)

Medium temperature range

50 to +150 В°C (58 to +302 В°F)

Max. process pressure

PN 100, Class 600, 63K

Wetted materials

Measuring tube: Titanium grade 9
Connection: Titanium grade 2

Max. measurement error

Mass flow (liquid): В±0.10 %
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.50 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 180 000 kg/h (0 to 6600 lb/min)

Medium temperature range

50 to +150 В°C (58 to +302 В°F)

Max. process pressure

PN 100, Class 600, 63K

Wetted materials

Measuring tube: Titanium grade 9
Connection: Titanium grade 2

Max. measurement error

Mass flow (liquid): В±0.5 % (standard), В±0.15 % (option)
Mass flow (gas): В±1 %

Measuring range

0 to 180 000 kg/h (0 to 6615 lb/min)

Medium temperature range

40 to +150 В°C (40 to +302 В°F)

Max. process pressure

PN 40, Class 300, 40K

Wetted materials

Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)

Max. measurement error

Mass flow (liquid): В±0.1 (standard), 0.05 % (option)
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.35 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 800 000 kg/h (0 to 29 400 lb/min)

Medium temperature range

40 to +205 В°C (40 to +401 В°F)

Max. process pressure

PN 250, Class 1500

Wetted materials

Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750)
Connection: 25Cr duplex (Super Duplex), 1.4410 (F53)

Max. measurement error

Mass flow (liquid): В±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.35 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 800 000 kg/h (0 to 29 400 lb/min)

Medium temperature range

40 to +205 В°C (40 to +401 В°F)

Max. process pressure

PN 250, Class 1500

Wetted materials

Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750)
Connection: 25Cr duplex (Super Duplex), 1.4410 (F53)

Max. measurement error

Mass flow (liquid): В±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.35 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 800 000 kg/h (0 to 29 400 lb/min)

Medium temperature range

40 to +205 В°C (40 to +401 В°F)

Max. process pressure

PN 250, Class 1500

Wetted materials

Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750)
Connection: 25Cr duplex (Super Duplex), 1.4410 (F53)

Max. measurement error

Mass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.5 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 70 000 kg/h (0 to 2570 lb/min)

Medium temperature range

Standard: 50 to +150 В°C (58 to +302 В°F)
Option: 50 to +205 В°C (58 to +401 В°F)

Max. process pressure

PN 63, Class 300, 40K

Wetted materials

Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)

Max. measurement error

Mass flow (liquid): В±0.10 %
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.50 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 70 000 kg/h (0 to 2570 lb/min)

Medium temperature range

Standard: 50 to +150 В°C (58 to +302 В°F)
Option: 50 to +205 В°C (58 to +401 В°F)

Max. process pressure

PN 40, Class 150, 20K

Wetted materials

Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)

Max. measurement error

Mass flow (liquid): В±0.10 %
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.50 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 70 000 kg/h (0 to 2570 lb/min)

Medium temperature range

Standard: 50 to +150 В°C (58 to +302 В°F)
Option: 50 to +205 В°C (58 to +401 В°F)

Max. process pressure

PN 40, Class 150, 20K

Wetted materials

Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)

Max. measurement error

Mass flow (liquid): В±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.35 %
Density (liquid): В±0.2 kg/mВі

Measuring range

0 to 400 000 kg/h (0 to 14 697 lb/min)

Medium temperature range

Standard: 50 to +205В°C (58 to +401 В°F)
Option: 196 to +150 В°C (321 to +302 В°F)

Max. process pressure

PN 100, Class 600, 63K

Wetted materials

Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications
Connection: 1.4404 (316/316L)

Max. measurement error

Mass flow (liquid): В±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.35 %
Density (liquid): В±0.2 kg/mВі

Measuring range

0 to 550 000 kg/h (0 to 20 210 lb/min)

Medium temperature range

Standard: 50 to +205В°C (58 to +401 В°F)
Option: 196 to +150 В°C (321 to +302 В°F)

Max. process pressure

PN 100, Class 600, 63K

Wetted materials

Measuring tube: 1.4404 (316/316L); stainless steel for cryogenic applications
Connection: 1.4404 (316/316L)

Max. measurement error

Mass flow (liquid): В±0.10 %
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.50 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 70 000 kg/h (0 to 2570 lb/min)

Medium temperature range

50 to +150 В°C (58 to +302 В°F)

Max. process pressure

PN 40, Class 150, 20K

Wetted materials

Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)

Max. measurement error

Mass flow (liquid): В±0.10 %
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.50 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 70 000 kg/h (0 to 2570 lb/min)

Medium temperature range

50 to +150 В°C (58 to +302 В°F)

Max. process pressure

PN 40, Class 150, 20K

Wetted materials

Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)"

Max. measurement error

Mass flow (liquid): В±0.10 %
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.50 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 70 000 kg/h (0 to 2570 lb/min)

Medium temperature range

50 to +150 В°C (58 to +302 В°F)

Max. process pressure

PN 40, Class 150, 20K

Wetted materials

Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)

Max. measurement error

Mass flow (liquid): В±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.35 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 4100 t/h (0 to 4520 tn. sh./h)

Medium temperature range

50 to +180 В°C (58 to +356 В°F)

Max. process pressure

PN 100, Class 600

Wetted materials

Measuring tube: 1.4404 (316/316L)
Connection: 1.4404 (316/316L)

Max. measurement error

Mass flow (liquid): В±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): В±0.10 %
Mass flow (gas): В±0.35 %
Density (liquid): В±0.0005 g/cmВі

Measuring range

0 to 4100 t/h (0 to 4520 tn. sh./h)

Medium temperature range

50 to +180 В°C (58 to +356 В°F)

Max. process pressure

PN 100, Class 600

Wetted materials

Measuring tube: 1.4404 (316/316L)
Connection: 1.4404 (316/316L)

Ultrasonic flow meter

Max. measurement error

Volume flow:
В±3% o.r. for DN15
В±2% o.r. for DN25 to 200
В±2% o.r. above DN200

Measuring range

0.3 to 10 m/s (1 to 33 ft/s)

Medium temperature range

-20 to +80В°C (-4 to +176 В°F)
0 to +130В°C (32 to +265 В°F) option

Max. process pressure

N/A

Wetted materials

Clamp on system:
Sensor holder 1.4308/CF-8
Sensor housing 1.4301/304
Strapping bands 1.4301/304

Ultrasonic flow meter

Max. measurement error

Volume flow (standard):
- В±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
Volume flow (option):
- В±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)

Ultrasonic flow meter

Max. measurement error

Volume flow:
В±3% o.r. for DN15
В±2% o.r. for DN25 to DN200
В±2% o.r. above DN200