Endress+Hauser Flow Meters
В±0.25 % o.r. В± 1 to 4 m/s (3.3 to 13 ft/s)
В±0.5 % o.r. В± 1 mm/s (0.04 in/s)
В±5 % o.r.
0.14 to 1.66 l/s (0.035 to 0.44 gal/s)
Medium temperature rangeSeal material EPDM: 20 to +130 В°C (4 to +266 В°F)
Seal material Silicone: 20 to +130 В°C (4 to +266 В°F)
Seal material Viton: 0 to +150 В°C (+32 to +302 В°F)
PN 16
Wetted materialsLiner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022), Tantalum,
Platinum
Mass flow (liquid): В±0.15 %
Density (liquid): В±0.0005 g/cmВі
0 to 18 000 kg/h (0 to 660 lb/min)
Medium temperature range40 to +125 В°C (40 to +257 В°F)
150 В°C allowed for 1 h
PN 40
Wetted materialsMeasuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Mass flow switch
Max. measurement error2% - 10% (per measurement range)
Medium temperature range-20...+85В°C
(-4...+185В°F)
CIP-able to 130В°C / 266В°F
100 bar (1.740 psi)
Mass flow switch
Max. measurement error2% - 10% (per measurement range)
Measuring range1"...40"
Medium temperature range-20...+85В°C
(-4...+185В°F)
CIP able to 130В°C / 266В°F
100 bar (1.740 psi)
Mass flow (liquid): В±0.15 %
Volume flow (liquid): В±0.15 %
(Reference condition)
0 to 18 000 kg/h (0 to 660 lb/min)
Medium temperature range196 to +125 В°C (320 to +257 В°F)
Max. process pressurePN 40, Class 300
Wetted materialsMeasuring tubes: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Mass flow (liquid): В±0.2 %
Volume flow (liquid): В±0.3 %
0 to 45 000 kg/h (0 to 1650 lb/min)
Medium temperature range40 to +125 В°C (40 to +257 В°F)
Max. process pressurePN 40, Class 300, 63K
Wetted materialsMeasuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Mass flow (liquid): В±0.20 %
Volume flow (liquid): В±0.30 %
0 to 70 000 kg/h (0 to 2570 lb/min)
Medium temperature range50 to +125 В°C (58 to +257 В°F)
Max. process pressurePN 40, Class 300
Wetted materialsMeasuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Max. measurement error
2%
Measuring range
0 to 56'550 m3/h
Medium temperature range
-20 to +120В°C
(-4 to +248В°F)
Max. process pressure
0 to 16 bar abs
Wetted materials
1.4435/316L
Volume flow: +/-0.8% o.r. +/- 0.2% o.f.s
Measuring rangeup to 750 l/min
Medium temperature range-10 to 70В°C (+14 to +158 В°F)
Permissible short-term temperature, maximum one hour:
85 В°C (185 В°F)
Repetition after 4 hours at the earliest
16 bar
Wetted materialsPEEK, Stainless Steel, FKM, EPDM
Electrodes: 1.4404/316L
Measuring range
0 to 1000 kg/h (0 to 37 lb/min)
Medium temperature range
50 to +205 В°C (58 to +401 В°F)
Max. process pressure
PN 40, Class 300, 10K, 400 bar (5800 psi)
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
Measuring range
0 to 1000 kg/h (0 to 37 lb/min)
Medium temperature range
50 to +205 В°C (58 to +401 В°F)
Max. process pressure
PN 40, Class 300, 10K, 400 bar (5800 psi)
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
Measuring range
0 to 1000 kg/h (0 to 37 lb/min)
Medium temperature range
50 to +205 В°C (58 to +401 В°F)
Max. process pressure
PN 40, Class 300, 10K, 400 bar (5800 psi)
Electromagnetic flowmeter
Max. measurement error
Volume flow: В±0.5 % o.r. В± 2 mm/s (В±0.5 % o.r. В± 0.08 in/s)
Measuring range
9 to 4700 dm3/min (2.5 to 1250 gal/min)
Medium temperature range
0 to +60 В°C (+32 to +140 В°F)
Max. process pressure
PN 16, Class 150, 10K
Max. measurement error
Volume flow: В±0.5 % o.r. В± 1 mm/s (0.04 in/s)
Measuring range
4 dmВі/min to 9600 mВі/h (1 to 44 000 gal/min)
Medium temperature range
10 to +110 В°C (+14 to +230 В°F)
Max. process pressure
PN 40, Class 150, 20K
Wetted materials
Liner: PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
Electromagnetic flowmeter
Measuring range
0.06 dm3/min to 600 m3/h (0.015 gal/min to 2650 gal/min)
Electromagnetic flowmeter
Measuring range
9 dmВі/min to 162 000 mВі/h (2.5 gal/min to 1030 Mgal/d)
Max. measurement error
Volume flow: В±0.5 % o.r. В± 2 mm/s (В±0.5 % o.r. В± 0.08 in/s)
Electromagnetic flowmeter
Max. measurement error
Volume flow: В±0,5% o.r. В± 2 mm/s (В±0,5% o.r. В± 0,08 in/s)
Measuring range
4 dm3/min to 9600 m3/h (0.5 gal/min to 44000 gal/min)
Medium temperature range
40 to +130В°C (40 to +266В°F)
Electromagnetic flowmeter
Max. measurement errorВ±0,5% o.r. В± 2 mm/s (В±0,5% o.r. В± 0,08 in/s)
Measuring range9 dm3/min to 110 000 m3/h (2.5 gal/min to 700 Mgal/day)
Medium temperature range'0 to +80 В°C (+32 to +176 В°F), 20 to +50 В°C (4 to +122 В°F)
Max. process pressurePN 40, Class 300, 20K
Wetted materialsLiner: polyurethane; hard rubber
Electromagnetic flowmeter
Max. measurement errorВ±0.5%
В±0.2% (optional)
0...9'600 m3/h
Medium temperature range-40...+150В°C
(-40...+302В°F)
PN10...40
Electromagnetic flowmeter
Max. measurement error
В±0.5%
В±0.2% (optional)
Measuring range
0...110'000 m3/h
Medium temperature range
-20...+80В°C
(-4...176В°F)
Max. process pressure
PN6...40
Electromagnetic flowmeter
Max. measurement errorVolume flow: В±0.5 % o.r.В± 1 mm/s (0.04 in/s)
Option: В±0.2 % o.r. В± 2 mm/s (0.08 in/s)
Electromagnetic flowmeter