Endress+Hauser
Free chlorine sensor
Free chlorine sensor
Chlorine dioxide sensor
Chlorine dioxide sensor
Trace: 0 to 5 mg/l ClO2
Standard: 0 to 20 mg/l ClO2
0 to 55 В°C (32 to 130В°F), non-freezing
Process pressureMax.1 bar (max. 14.5 psi)
Measuring methodClosed, membrane covered measuring cell
Reduction of chlordioxide at the cathode
Trace: 0 to 5 mg/l HOCl
Standard: 0 to 20 mg/l HOCl
+0 to 55 В°C (32 to 130В°F), non-freezing
Process pressure1 bar (14.5 psi)
Measuring method- Closed, membrane covered measuring cell
- Reduction of free chlorine at the cathode
0.5%
Process temperature-25 В°...+85 В°C
(-13 В°F...+185 В°F)
+400 mbar...+40 bar
(+6 psi...+600 psi)
+400 mbar...+40 bar
(+6 psi...+600 psi)
Pressure transducer
Accuracy0.3 %
Process temperature-25 В°...+100 В°C
(-13 В°F....+185 В°F)
+100 mbar...+40 bar
(+1.5 psi...+600 psi)
+100 mbar...+40 bar
(+1.5 psi...+600 psi)
Pressure transmitter
AccuracyStandard 0.1%
Platinum 0.075%
-20В°C...125В°C
(-4В°F...275В°F)
100 mbar...40 bar
(1.5psi...600psi)
60 bar (900 psi)
Main wetted partsCeraphire
Sealing
Alloy C276
316L
400 m (1312 ft) H2O
Material process membraneCeramic
Measuring cell100 mbar...40 bar
(1.5 psi...600 psi)
relative/ absolute
Standard:
up to 0.075 %
Platinum:
up to 0.055 %
-40В°C...+100В°C
(-40В°F...+212В°F)
100 mbar...40 bar
(1.5 psi...600 psi)
Ceraphire ceramic
FKM, EPDM, HNBR,
Perlast, Kalrez
Ceramic
Measuring cell100 mbar...40 bar
(1.5 psi...600 psi)
Pressure transducer
AccuracyStandard: 0.05%
Platinum: up to 0.025%
-40В°C...150В°C
(-40В°F...302В°F)
100mbar...40bar
(1.5psi...600psi)
60bar (900psi)
Main wetted partsCeraphire ceramic
Alloy C
316L
Monel
PVDF
400m (1312ft) H2O
Material process membraneCeramic
Measuring cell100 mbar...40 bar
(1.5 psi...600 psi)
relative/ absolute
Standard:
up to 0.05 %
Platinum:
up to 0.025 %
-40В°C...+150В°C
(-40В°F...+302В°F)
100 mbar...40 bar
(1.5 psi...600 psi)
Ceraphire ceramic
FKM, EPDM, HNBR,
Perlast, Kalrez, Chemraz
Ceramic
Measuring cell100 mbar....40 bar
(1.5 psi...600 psi)
0.5%
Process temperature-25...+85В°C
(-13...+185В°F)
400 mbar...+40 bar
(6 psi...+600 psi)
400 mbar...+40 bar
(6 psi...+600 psi)
0.3%
Process temperature-40...+100В°C
(-40...+212В°F)
400 mbar...+400 bar
(6...+6000psi)
+400 mbar...+400 bar
(+6 psi...+6000 psi)
0.3%
Process temperature-10...+100В°C
(+14...+212В°F)
135В°C for 1h
(275В°F for 1h)
400 mbar...+40 bar
(6...+600psi)
+400 mbar...+40 bar
(+6 psi...+600 psi)
Pressure transducer
AccuracyStandard 0.1%
Platinum 0.075%
-40В°C...125В°C
(-40В°F...275В°F)
1 bar...400 bar
(15 psi...6000 psi)
600 bar (9000 psi)
Main wetted parts316L
Max. measurement distance4000 m (13.123 ft) H2O
Material process membrane316L, AlloyC,
Rhodium>Gold
400mbar...400bar
(15psi...6000psi)
relative/ absolute
Standard:
up to 0.075 %
Platinum
up to 0.055 %
Standard:
-40В°...+125В°C
(-40В°F...+257В°F)
Diaphragm seal:
-40В°C...+400В°C
(-40В°F...+752В°F)
400 mbar... 400 bar
(6psi...6,000psi)
316L, AlloyC,
Tantal, Monel,
PTFE
316L, AlloyC,
Tantal, Monel,
PTFE
400 mbar...400 bar
(6psi...6,000psi)
Pressure transducer
AccuracyStandard 0.15%
Platinum 0.075%
-70В°...400В°C
(-94В°F...752В°F)
1 bar...400 bar
(15 psi...6000 psi)
600 bar (9000 psi)
Main wetted parts316L
AlloyC
Montel
Tantal
Rhodium
4000m (13.123ft) H2O
Material process membrane316L, AlloyC,
Tantal, PTFE,
Rhodium>Gold
400 mbar...400 bar
(15 psi...6000 psi)
relative/ absolute
Pressure transducer
AccuracyStandard: 0.05%
Platinum: up to 0.025%
-40В°C...125В°C
(-40В°F...257В°F)
100mbar...700bar
(1.5psi...10.500psi)
Alloy C276
316L
Rhodium
316L, AlloyC,
Rhodium> Gold
100 mbar...700 bar
(1.5 psi...10.500 psi)
relative/ absolute
Standard:
up to 0.05 %
Platinum:
up to 0.025 %
Standard:
-40В°...+125В°C
(-40В°F...+257В°F)
Diaphragm seal:
-40В°C...+400В°C
(-40В°F...+752В°F)
400 mbar...700 bar
(1.5 psi...10,500 psi)
316L, AlloyC,
Tantal, Monel,
PTFE, Gold
316L, AlloyC,
Tantal, Monel,
PTFE,
Gold
400 mbar...700 bar
(6 psi...10,500 psi)
Pressure transducer
Accuracy0,075% + influence of diaphragm seal
Process temperature-70В°C...400В°C
(-94В°F...752В°F)
Pressure transducer
Pressure transducer
Pressure transducer
Analog pH electrode for ORP measurement
Measurement rangepH 0-14
Process temperature-15В°C ... 140В°C
(5В°F - 284В°F)
max. 13 bar
(188 psi)
Digital pH electrode for measuring ORP
Measurement rangepH 0 to 14
Process temperature0 to 140 В°C (32 to 284 В°F)
Process pressure1 to 14 bar (15 to 203 psi)
Analog pH electrode for ORP measurement
Measurement range-1500 mV - +1500 mV
Process temperature-15В°C - 135В°C
Process pressuremax. 16bar
Digital pH electrode for measuring ORP
Measurement range-1500mV - +1500mV
Process temperature-15В°C - 140В°C
Process pressuremax. 16bar