Endress+Hauser

Choose a subcategory:
Show all categories

Holder

Process temperature

-20 to 60 В°C (-4 to 140 В°F)

Process temperature

Max. 60 В°C
(Max. 140 В°F)

Process pressure

Max. 4 bar relative
(Max. 58 psi relative)

Process temperature

max. 45В°C

Process pressure

max. 4bar

Flow fitting

Process temperature

max. 50В°C
(max. 122В°F)

Process pressure

max. 6bar
(max.87psi)

Flow fitting

Process temperature

PVDF version: 0 to 120 В°C (32 to 248 В°F)
Stainless steel version: -15 to 150 В°C (5 to 302 В°F)
With EPDM: -15 to 140 В°C (5 to 284 В°F)

Process pressure

PVDF version: max. 8 bar at 50 В°C (max. 116 psi at 122 В°F)
Stainless steel version: max. 10 bar (max. 145 psi)

Process temperature

max. 80В°C

Process pressure

max. 6bar (20В°C)

Flow fitting

Process temperature

max. 50В°C
(max. 122В°F)

Process pressure

max. 6bar
(max.87psi)

Process temperature

0 .. 60В°C

Process pressure

0 .. 6 bars

Process temperature

0 .. 85В°C

Process pressure

0 .. 6 bars

Process pressure

Max. 16 bar (relative)

Flow assembly for water, wastewater and utilities.
Process temperature

0 to 60 В°C (32 to 140В°F)

Process pressure

0 to 4 bar (0 to 58 psi) relative

Mass flow switch

Max. measurement error

2% - 10% (per measurement range)

Medium temperature range

-20...+85В°C
(-4...+185В°F)
CIP-able to 130В°C / 266В°F

Max. process pressure

100 bar (1.740 psi)

Mass flow switch

Max. measurement error

2% - 10% (per measurement range)

Measuring range

1"...40"

Medium temperature range

-20...+85В°C
(-4...+185В°F)
CIP able to 130В°C / 266В°F

Max. process pressure

100 bar (1.740 psi)

Density calculator

Measurement of density, reference density, concentration of liquids in conjunction with a Liquiphant.

Field process indicator

Input

Foundation Fieldbus protocol
PROFIBUS PA protocol

Output

Not defined

Display

High contrast backlit LCD with bargraph
TAG/unit

Power Supply

Not defined

Ready-to-use bundle for disinfection monitoring in seawater and process water.
Ready-to-use panel bundle for reliable and precise monitoring of disinfection processes.
Effective suppression of background radiation and extraneous radiation at the Gammapilot FMG50.
Process pressure absolute / max. overpressure limit

Any

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Max. measurement distance

Unlimited measuring range,
Cascade

Accuracy

+/-1%

Main wetted parts

Non-contact

Radioisotope level measurement system

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Min. density of medium

Any

Max. measurement distance

Unlimited measuring range
Cascade

Min. conductivity of medium

Any

Accuracy

+/-1%

Main wetted parts

Non-contact

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Min. density of medium

Any

Min. conductivity of medium

Any