Endress+Hauser
Micropulse level gauge
AccuracyRod probe: +/- 2 mm (0.08 in)
Rope probe: +/- 2 mm (0.08 in)
-20...+80 В°C
(-4...+176 В°F)
Vacuum...6 bar,
(Vacuum...87 psi)
Rod: 4 m (13 ft) Min DK>1.6
Rope: 12 m (40 ft) Min DK>1.6
Rod probe: 316L, PPS, Viton
Rope probe: 316, PPS, Viton
Micropulse level gauge
AccuracyRod probe :+/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in)
Coaxial probe: +/- 2 mm (0.08 in)
-50...+200 В°C
(-58...+392 В°F)
Vacuum...40 bar
(Vacuum...580 psi)
Rod: 10 m (33 ft) Min DK>1.6
Rope: 25 m...30 m (82ft...98 ft) Min DK>1.6;
30m...45 m (98ft...148 ft) Min DK>1,9
Coaxial probe: 6 m (20 ft) Min DK>1.4
Rod probe:
316L, Alloy C, Ceramic
Rope probe:
316, 316L, Alloy C, Ceramic
Coaxial probe:
316L, Alloy C, Ceramic, PFA
Micropulse level gauge
AccuracyRod probe :+/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):
+/- 10 mm (0.39 in)
-50...+200 В°C
(-58...+392 В°F)
Vacuum...40 bar
(Vacuum...580 psi)
Rod:
4 m (13 ft) Min DK>1.6
Rope:
25 m...30 m (82 ft...98 ft) Min DK>1.6;
30 m...45 m (98 ft...148 ft) Min DK>1,9
Rod probe:
304, 304L, 316L, PTFE, PFA
Rope probe:
304, 304L, 316, 316L, PTFE, PFA
Micropulse level gauge
AccuracyRod probe:+/- 2 mm (0.08 in)
Process temperature-20...+150 В°C
(-4...+302 В°F)
Vacuum...16 bar
(Vacuum...232 psi)
Rod: 6 m (20 ft)
Min DK>1.6
Rod probe:
304, 304L, 316L, PEEK
Micropulse level gauge
AccuracyRod probe: +/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):
+/- 10 mm (0.39 in)
Coaxial probe: +/- 2 mm (0.08 in)
XT: -196...+280 В°C
(-321...+536 В°F)
HT: -196...+450 В°C
(-321...+842 В°F)
Vacuum...400 bar
(Vacuum...5800 psi)
Rod:
10 m (33 ft) Min DK>1.6
Rope:
25 m...30 m (82 ft...98 ft) Min DK>1.6;
30 m...45 m (98 ft...148 ft) Min DK >1,9
Coaxial probe: 6 m (20 ft) Min DK>1.4
Rod probe:
304, 316L, Alloy C, Ceramic
Rope probe:
304, 316, 316L, Alloy C, Ceramic
Coaxial probe:
304, 316L, Alloy C, Ceramic
Micropulse level gauge
AccuracyRod probe :
+/- 2 mm (0.08 in)
Rope probe:
+/- 2 mm (0.08 in)
Coaxial probe:
+/- 2 mm (0.08 in)
-40...+200 В°C
(-40...+392 В°F)
Vacuum...40 bar
(Vacuum...580 psi)
Rod: 4 m (13 ft)
Min DK >1.4
Rope: 10 m (33 ft)
Min DK >1.4
Coaxial: 6 m (20 ft)
Min DK >1.4
Rod probe:
316L, PTFE, PFA
Rope probe:
316, 316L, PTFE, PFA
Coaxial probe:
316L, PTFE, PFA
Micropulse level gauge
AccuracyRope probe: +/- 2 mm (0.08 in)
Process temperature40...+120 В°C
(40...+248 В°F)
Vacuum...16 bar
(Vacuum...232 psi)
Rope: 12 m (40 ft)
Min DK >1.4
Rope probe:
304, 316, 316Ti, 316L, PEEK, PPS, PA
Micropulse level gauge
AccuracyRod probe: +/- 2 mm (0.08 in)
Rope probe <= 15 m (49ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49ft):
+/- 10 mm (0,39 in)
-40...+150 В°C
(-40...+302 В°F)
Vacuum...16 bar
(Vacuum...232 psi)
Rod:
4 m (13 ft) Min DK>1.4
Rope:
20 m...25 m (66 ft...82 ft) Min DK >1.4;
25 m...30 m (82ft...98 ft) Min DK >1.6;
30 m...45 m (98ft...148 ft) Min DK>1,9
Rod probe:
316Ti, 316L, PEEK, PPS
Rope probe:
304, 316, 316Ti, 316L, PEEK, PPS, PA
Micropulse level gauge
Micropulse level gauge
Micropulse level gauge
Capacitive level transmitter
Accuracy< 1%
Process temperature-40 В°C ... 100 В°C
(-40 В°F ... 212 В°F)
Vacuum ... 10 bar
(Vacuum ... 145 psi)
2.5 m (8 ft)
Main wetted partsProbe rods:
316L/1.4404 / PP
Option: carbon fibre PP coated
Capacitive level transmitter
AccuracyRepeatablity 0,1%
Process temperature-80В°C...200В°C
-112В°F...392В°F
Vacuum ... 100 bar
(Vaccum ... 1450 psi)
0.1 m ... 4.0 m
(0.3 ft ... 13 ft)
Insulation material: PTFE,PFA
316L
Capacitive level transmitter
Accuracyrepeatablity 0,1%
Process temperature-80В°C...200В°C
-112В°F...392В°F
Vacuum ... 100 bar
(Vaccum ... 1450 psi)
0.42 m ... 10.0 m
(1.38 ft ... 33 ft)
Insulation material: FEP,PFA
316L
Capacitive level transmitter
Process temperature-80 В°C ... +200 В°C
(-112 В°F ... +392 В°F)
Vacuum ... 100 bar
(Vacuum ... 1450 psi)
Capacitive level transmitter
Process temperature-80 В°C ... +200 В°C
(-112 В°F ... +392 В°F)
Vacuum ... 100 bar
(Vacuum ... 1450 psi)
Float level switch
One-channel-transmitter
Output / communication0/4-20mA
Ingres protectionFront IP65 , NEMA 4X, Body IP20
Liquid Oxygen Sensor
Input1 to 2x Memosens digital input
Output / communication2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay
IP66 / IP67
1 to 2x Memosens digital input
2x 0/4 to 20mA Input optional
2x Digital input optional
2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay, ProfibusDP, Modbus RS485,
Modbus TCP, Ethernet
Transmitter: IP20
Optional Display: IP66
Turbidity Analysis Sensor
Input1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional
2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
IP66 / IP 67
1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional
2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Transmitter: IP20
Optional Display: IP66
Fluid Conductivity Transducer
Input1 to 8x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional
2 to 8x 0/4 to 20 mA current outputs, alarmrelay
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
IP66 / IP67
1...8x Memosens digital input
2x 0/4..20mA Input optional
2..4x Digital input optional
2...8x 0/4...20 mA current outputs
alarmrelay
4x relay
ProfibusDP
Modbus RS485
Modbus TCP
Ethernet
IP20 transmitter
IP66 optional Display
Cabinet device: IP20 shock protection
External display: IP66
Field device: IP 66/67
One channel transmitter
Output / communication4 to 20 mA
Ingres protectionIP67, IP68, NEMA Type 6
One channel transmitter
Output / communication4 to 20 mA, HART
Ingres protectionIP67, IP68, NEMA Type 6
Fluid Conductivity Transducer
InputOne channel transmitter for Memosens and analog (pH, ORP, conductivity)
Output / communication1/2 x 4 to 20 mA, HART, Profibus PA, FF
Additional second output possible, also later
IP66/67, NEMA 4X