Endress+Hauser

Choose a subcategory:
Show all categories

Micropulse level gauge

Accuracy

Rod probe: +/- 2 mm (0.08 in)
Rope probe: +/- 2 mm (0.08 in)

Process temperature

-20...+80 В°C
(-4...+176 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...6 bar,
(Vacuum...87 psi)

Max. measurement distance

Rod: 4 m (13 ft) Min DK>1.6
Rope: 12 m (40 ft) Min DK>1.6

Main wetted parts

Rod probe: 316L, PPS, Viton
Rope probe: 316, PPS, Viton

Micropulse level gauge

Accuracy

Rod probe :+/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in)
Coaxial probe: +/- 2 mm (0.08 in)

Process temperature

-50...+200 В°C
(-58...+392 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...40 bar
(Vacuum...580 psi)

Max. measurement distance

Rod: 10 m (33 ft) Min DK>1.6
Rope: 25 m...30 m (82ft...98 ft) Min DK>1.6;
30m...45 m (98ft...148 ft) Min DK>1,9
Coaxial probe: 6 m (20 ft) Min DK>1.4

Main wetted parts

Rod probe:
316L, Alloy C, Ceramic
Rope probe:
316, 316L, Alloy C, Ceramic
Coaxial probe:
316L, Alloy C, Ceramic, PFA

Micropulse level gauge

Accuracy

Rod probe :+/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):
+/- 10 mm (0.39 in)

Process temperature

-50...+200 В°C
(-58...+392 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...40 bar
(Vacuum...580 psi)

Max. measurement distance

Rod:
4 m (13 ft) Min DK>1.6
Rope:
25 m...30 m (82 ft...98 ft) Min DK>1.6;
30 m...45 m (98 ft...148 ft) Min DK>1,9

Main wetted parts

Rod probe:
304, 304L, 316L, PTFE, PFA
Rope probe:
304, 304L, 316, 316L, PTFE, PFA

Micropulse level gauge

Accuracy

Rod probe:+/- 2 mm (0.08 in)

Process temperature

-20...+150 В°C
(-4...+302 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...16 bar
(Vacuum...232 psi)

Max. measurement distance

Rod: 6 m (20 ft)
Min DK>1.6

Main wetted parts

Rod probe:
304, 304L, 316L, PEEK

Micropulse level gauge

Accuracy

Rod probe: +/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):
+/- 10 mm (0.39 in)
Coaxial probe: +/- 2 mm (0.08 in)

Process temperature

XT: -196...+280 В°C
(-321...+536 В°F)
HT: -196...+450 В°C
(-321...+842 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...400 bar
(Vacuum...5800 psi)

Max. measurement distance

Rod:
10 m (33 ft) Min DK>1.6
Rope:
25 m...30 m (82 ft...98 ft) Min DK>1.6;
30 m...45 m (98 ft...148 ft) Min DK >1,9
Coaxial probe: 6 m (20 ft) Min DK>1.4

Main wetted parts

Rod probe:
304, 316L, Alloy C, Ceramic
Rope probe:
304, 316, 316L, Alloy C, Ceramic
Coaxial probe:
304, 316L, Alloy C, Ceramic

Micropulse level gauge

Accuracy

Rod probe :
+/- 2 mm (0.08 in)
Rope probe:
+/- 2 mm (0.08 in)
Coaxial probe:
+/- 2 mm (0.08 in)

Process temperature

-40...+200 В°C
(-40...+392 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...40 bar
(Vacuum...580 psi)

Max. measurement distance

Rod: 4 m (13 ft)
Min DK >1.4
Rope: 10 m (33 ft)
Min DK >1.4
Coaxial: 6 m (20 ft)
Min DK >1.4

Main wetted parts

Rod probe:
316L, PTFE, PFA
Rope probe:
316, 316L, PTFE, PFA
Coaxial probe:
316L, PTFE, PFA

Micropulse level gauge

Accuracy

Rope probe: +/- 2 mm (0.08 in)

Process temperature

40...+120 В°C
(40...+248 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...16 bar
(Vacuum...232 psi)

Max. measurement distance

Rope: 12 m (40 ft)
Min DK >1.4

Main wetted parts

Rope probe:
304, 316, 316Ti, 316L, PEEK, PPS, PA

Micropulse level gauge

Accuracy

Rod probe: +/- 2 mm (0.08 in)
Rope probe <= 15 m (49ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49ft):
+/- 10 mm (0,39 in)

Process temperature

-40...+150 В°C
(-40...+302 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...16 bar
(Vacuum...232 psi)

Max. measurement distance

Rod:
4 m (13 ft) Min DK>1.4
Rope:
20 m...25 m (66 ft...82 ft) Min DK >1.4;
25 m...30 m (82ft...98 ft) Min DK >1.6;
30 m...45 m (98ft...148 ft) Min DK>1,9

Main wetted parts

Rod probe:
316Ti, 316L, PEEK, PPS
Rope probe:
304, 316, 316Ti, 316L, PEEK, PPS, PA

Micropulse level gauge

Micropulse level gauge

Micropulse level gauge

Capacitive level transmitter

Accuracy

< 1%

Process temperature

-40 В°C ... 100 В°C
(-40 В°F ... 212 В°F)

Process pressure absolute / max. overpressure limit

Vacuum ... 10 bar
(Vacuum ... 145 psi)

Max. measurement distance

2.5 m (8 ft)

Main wetted parts

Probe rods:
316L/1.4404 / PP
Option: carbon fibre PP coated

Capacitive level transmitter

Accuracy

Repeatablity 0,1%

Process temperature

-80В°C...200В°C
-112В°F...392В°F

Process pressure absolute / max. overpressure limit

Vacuum ... 100 bar
(Vaccum ... 1450 psi)

Max. measurement distance

0.1 m ... 4.0 m
(0.3 ft ... 13 ft)

Main wetted parts

Insulation material: PTFE,PFA
316L

Capacitive level transmitter

Accuracy

repeatablity 0,1%

Process temperature

-80В°C...200В°C
-112В°F...392В°F

Process pressure absolute / max. overpressure limit

Vacuum ... 100 bar
(Vaccum ... 1450 psi)

Max. measurement distance

0.42 m ... 10.0 m
(1.38 ft ... 33 ft)

Main wetted parts

Insulation material: FEP,PFA
316L

Capacitive level transmitter

Process temperature

-80 В°C ... +200 В°C
(-112 В°F ... +392 В°F)

Process pressure absolute / max. overpressure limit

Vacuum ... 100 bar
(Vacuum ... 1450 psi)

Capacitive level transmitter

Process temperature

-80 В°C ... +200 В°C
(-112 В°F ... +392 В°F)

Process pressure absolute / max. overpressure limit

Vacuum ... 100 bar
(Vacuum ... 1450 psi)

Float level switch

Input

One-channel-transmitter

Output / communication

0/4-20mA

Ingres protection

Front IP65 , NEMA 4X, Body IP20

Liquid Oxygen Sensor

Input

1 to 2x Memosens digital input

Output / communication

2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay

Ingres protection

IP66 / IP67

Input

1 to 2x Memosens digital input
2x 0/4 to 20mA Input optional
2x Digital input optional

Output / communication

2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay, ProfibusDP, Modbus RS485,
Modbus TCP, Ethernet

Ingres protection

Transmitter: IP20
Optional Display: IP66

Turbidity Analysis Sensor

Input

1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional

Output / communication

2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet

Ingres protection

IP66 / IP 67

Input

1 to 4x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional

Output / communication

2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet

Ingres protection

Transmitter: IP20
Optional Display: IP66

Fluid Conductivity Transducer

Input

1 to 8x Memosens digital input
2x 0/4 to 20mA Input optional
2 to 4x Digital input optional

Output / communication

2 to 8x 0/4 to 20 mA current outputs, alarmrelay
4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet

Ingres protection

IP66 / IP67

Input

1...8x Memosens digital input
2x 0/4..20mA Input optional
2..4x Digital input optional

Output / communication

2...8x 0/4...20 mA current outputs
alarmrelay
4x relay
ProfibusDP
Modbus RS485
Modbus TCP
Ethernet

Ingres protection

IP20 transmitter
IP66 optional Display

Ingres protection

Cabinet device: IP20 shock protection
External display: IP66
Field device: IP 66/67

Input

One channel transmitter

Output / communication

4 to 20 mA

Ingres protection

IP67, IP68, NEMA Type 6

Input

One channel transmitter

Output / communication

4 to 20 mA, HART

Ingres protection

IP67, IP68, NEMA Type 6

Fully automatic system for pH and ORP measuring points in all industries.

Fluid Conductivity Transducer

Input

One channel transmitter for Memosens and analog (pH, ORP, conductivity)

Output / communication

1/2 x 4 to 20 mA, HART, Profibus PA, FF
Additional second output possible, also later

Ingres protection

IP66/67, NEMA 4X