Endress+Hauser
Standard sensor: 0 to 60 mg/l, 0 to 600 %SAT, 0 to 1200 hPa, 0 to 100 Vol%
Trace sensor: 0 to 10 mg/l, 0 to 120 %SAT, 0 to 250 hPa, 0 to 25 Vol%
-5 to 135 В°C (23 to 275 В°F)
Process pressure1 to 12 bar abs (14.5 to 174 psi)
0.01 to 100 mg/l
0.00 to 1000 %SAT
0 to 2000 hPa
-5 to 60 В°C
(20 to 140 В°F)
Max. 5 bar abs
(Max. 72.5 psi abs)
0.004 to 30 mg/l
0.05 to 330 %SAT
0.1 to 700 hPa
0 to 140 В°C
(32 to 284 В°F)
0.02 to 13 bar abs
(0 to 190 psi)
0.004 to 30 mg/l
0.05 to 330 %SAT
0.1 to 700 hPa
1 to 140 В°C
(32 to 284 В°F)
0.02 to 13 bar abs
(0 to 190 psi)
pH 0 to 14
Process temperatureVersion LH: 0 to 110 В°C (32 to 230 В°F)
Version NN: 0 to 80 В°C (32 to 170 В°F)
1 to 10 bar abs at 80 В°C
(15 to 145 psi at 176 В°F)
-1500mV to +1500mV
Process temperature0 to 80 В°C (32 to 170 В°F)
Process pressure1 to 10 bar abs at 80 В°C
(15 to 145 psi abs at 176 В°F)
pH 0 to 14 (1 to 12 application range)
Process temperature-5 to 80 В°C (23 to 176 В°F)
Process pressure1 bar, not intended for continues measurment in process
pH 0 to 14 (1 to 12 application range)
Process temperature5 to 100 В°C (23 to 212 В°F) (0 to 80 В°C (32 to 176 В°F) application range)
Process pressure1 bar, not intended for continues measurment in process
pH 0 to 14 (1 to 12 application range)
Process temperature5 to 100 В°C (23 to 212 В°F) (0 to 80 В°C (32 to 176 В°F) application range)
Process pressure1 bar, not intended for continues measurment in process
pH 0 to 14
Process temperature0 to 135 В°C (32 to 275 В°F) (0 to 100 В°C (32 to 212 В°F) application range)
Process pressure1 bar, not intended for continues measurement in process
Application A
pH: 1 to 12
Application B
pH: 0 to 14
Application F
pH: 0 to 10
Application A: 15 to 80 В°C (5 to 176 В°F)
Application B: 0 to 135 В°C (32 to 275 В°F)
Application F: 0 to 70 В°C (32 to 158 В°F)
Applications A and B:
0.8 to 17 bar (11.6 to 246.5 psi) absolute
Application F:
0.8 to 7 bar (11.6 to 101.5 psi) absolute
-1500 mV to +1500 mV
Process temperature-15 to 135 В°C
(5 to 275 В°F)
0.8 to 17 bar (11.6 to 246.5 psi) absolute
Liquid PH and ORP analysis sensor
Process temperature0 to 135 В°C (32 to 275 В°F)
Process pressure1 to 17 bar (15 to 246 psi)
ORP: 1 500 to 1 500 mV
Application A
pH: 1 to 12
Application B
pH: 0 to 14
Application A: 15 to 80 В°C (5 to 176 В°F)
Application B: 0 to 135 В°C (32 to 275 В°F)
0.8 to 17 bar (11.6 to 246,5 psi) absolute
pH 0 to 14
Process temperature0 to 135 В°C (32 to 275 В°F)
Process pressure1 to 7 bar abs (14.5 to 101.5 psi)
pH 1 to 12
Process temperature0 to 80 В°C
(32 to 176 В°F)
1 to 4 bar
(15 to 60 psi)
pH 1 to 13
Process temperature15 to 80 В°C (5 to 176 В°F)
Process pressure0.8 to 4 bar (11.6 to 58 psi) (absolute)
Application A
pH: 1 to 12
Application B
pH: 0 to 14
Application A: 15 to 80 В°C (5 to 176 В°F)
Application B: 0 to 135 В°C (32 to 275 В°F)
0.8 to 11 bar (11.6 to 159.5 psi) absolute
1 500 to 1 500 mV
Process temperature15 to 135 В°C (5 to 275 В°F)
Process pressure0.8 to 11 bar (11.6 to 159.5 psi) (absolute)
pH 0 to 14
Process temperature-15 to 135 В°C (5 to 275 В°F)
Process pressureMax. 11 bar abs at 100 В°C (max. 160 psi at 212 В°F)
pH: 0 to 14
Process temperatureApplication N:
0 to 100 В°C (32 to 212 В°F)
Up to 140 В°C (284 В°F) for sterilization
0.8 to 7 bar (11.6 to 101.5 psi) absolute
1 500 to 1 500 mV
Process temperature0 to 100 В°C (32 to 212 В°F)
0 to 140 В°C (32 to 284 В°F) (140 В°C (284 В°F) or sterilization only)
0.8 to 7 bar (11.6 to 101.5 psi) absolute
Application B:
pH: 0 to 14
Application H:
pH: 0 to 12
1 to 140 В°C (32 to 284 В°F)
Process pressure0,8 to 14 bar (11,6 to 203 psi) (absolute)
1 500 to 1 500 mV
Process temperature0 to 140 В°C (32 to 284 В°F)
Process pressure0.8 to 14 bar (11.6 to 203 psi) (absolute)
Liquid PH and ORP analysis sensor
Measurement rangepH 0-14
Process temperature-15В°C ... 140В°C
(5В°F - 284В°F)
max. 13 bar
(188 psi)depends on selected version
ORP: 1 500 to 1 500 mV
Application B
pH: 0 to 14
Application H
pH: 0 to 12
Application B and H:
0 to 140 В° C (32 to 284 В° F)
Version TB:
0 to 140 В° C (32 to 284 В° F)
Version TU, TP (pressurized reference):
0 to 140 В° C (32 to 284 В° F) (140 В° C (284 В° F) for sterilization only)
maximum 100 В° C (212 В° F) in continuous operation due to increasing
pressure drop at T> 100 В° C (212 В° F)
Application B: 0.8 to 14 bar (11.6 to 203 psi) absolute
Application H: 0.8 to 7 bar (11.6 to 101,5 psi) absolute
pH 0 to 14
Process temperature-15 to 135В°C (5 to 275В°F)
Process pressureMax. 11 bar abs at 100 В°C
(Max. 160 psi at 212 В°F)
1 to 14 pH
Process temperature0 to 110 В°C (32 to 230 В°F)
Process pressure0.8 to 14 bar (11.6 to 203 psi) absolute