Endress+Hauser

Choose a subcategory:
Show all categories
Accuracy

class 1 acc. to IEC 60584
class 2 acc. to IEC 60584
class Special ASTM E230 and ANSI MC 96.1
IEC60751 Class A
IEC60751 Class AA

Response time

TC
t50 = 1 s
t90 = 2 s
RTD
t50 = 3 s
t90 = 6 s

Max. process pressure (static)

at 20 В°C: 40 bar (580 psi)

Operating temperature range

Type K:
-270 В°C ...800 В°C
(-454 В°F ...1.472 В°F)
Type J:
-210 В°C ...520 В°C
(-346 В°F ...968 В°F)
Pt100 WW; 3mm; 316L; -200...600oC
Pt100 StrongSens; 6mm; 316L; -50...500oC
Pt100 TF; 3mm; 316L; -50...400oC

Max. immersion length on request

up to 60.000,00 mm (2.360'')

Comfortable temperature measurement solution 100% compliance, 0% effort.
Automated temperature measurement solution - 100% compliance, 0% effort.
Response time

t50 = 2.5 s
t90 = 5.4 s

Max. process pressure (static)

at 20 В°C: 40 bar (580 psi)

Operating temperature range

Pt 100:
-40 В°C to 160 В°C
(-40 В°F to 320 В°F)

Max. immersion length on request

up to 900.00 mm (35.4'')

Response time

t50 = 2,5 s
t90 =9,5s

Max. process pressure (static)

at 20 В°C: 40 bar (580 psi)

Operating temperature range

PT 100:
-40 В°C ...160 В°C
(-40 В°F ...320 В°F)

Max. immersion length on request

up to 28'' (711 mm)
others on request

Max. process pressure (static)

40 bar (580 psi)

Maximum standard immersion length

4.000 mm (157,48")

Max. immersion length on request

Not defined

Max. process pressure (static)

40 bar (580 psi)

Maximum standard immersion length

48" (1.219 mm)

Resistance thermometer
Resistance thermometer
Measured Variables

Concentration
Dew Point
Cell Pressure
Cell Temperature

Hazardous area approvals

ATEX / IECEx Zone 1
UKEx Zone 1
CSA Class I, Division 1
CSA Class I, Zone 1

Micropulse level gauge

Accuracy

Rod probe: +/- 2 mm (0.08 in)
Rope probe: +/- 2 mm (0.08 in)

Process temperature

-20...+80 В°C
(-4...+176 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...6 bar,
(Vacuum...87 psi)

Max. measurement distance

Rod: 4 m (13 ft) Min DK>1.6
Rope: 12 m (40 ft) Min DK>1.6

Main wetted parts

Rod probe: 316L, PPS, Viton
Rope probe: 316, PPS, Viton

Micropulse level gauge

Micropulse level gauge

Accuracy

Rod probe :+/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):
+/- 10 mm (0.39 in)

Process temperature

-50...+200 В°C
(-58...+392 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...40 bar
(Vacuum...580 psi)

Max. measurement distance

Rod:
4 m (13 ft) Min DK>1.6
Rope:
25 m...30 m (82 ft...98 ft) Min DK>1.6;
30 m...45 m (98 ft...148 ft) Min DK>1,9

Main wetted parts

Rod probe:
304, 304L, 316L, PTFE, PFA
Rope probe:
304, 304L, 316, 316L, PTFE, PFA

Micropulse level gauge

Accuracy

Rod probe:+/- 2 mm (0.08 in)

Process temperature

-20...+150 В°C
(-4...+302 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...16 bar
(Vacuum...232 psi)

Max. measurement distance

Rod: 6 m (20 ft)
Min DK>1.6

Main wetted parts

Rod probe:
304, 304L, 316L, PEEK

Micropulse level gauge

Accuracy

Rod probe: +/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):
+/- 10 mm (0.39 in)
Coaxial probe: +/- 2 mm (0.08 in)

Process temperature

XT: -196...+280 В°C
(-321...+536 В°F)
HT: -196...+450 В°C
(-321...+842 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...400 bar
(Vacuum...5800 psi)

Max. measurement distance

Rod:
10 m (33 ft) Min DK>1.6
Rope:
25 m...30 m (82 ft...98 ft) Min DK>1.6;
30 m...45 m (98 ft...148 ft) Min DK >1,9
Coaxial probe: 6 m (20 ft) Min DK>1.4

Main wetted parts

Rod probe:
304, 316L, Alloy C, Ceramic
Rope probe:
304, 316, 316L, Alloy C, Ceramic
Coaxial probe:
304, 316L, Alloy C, Ceramic

Micropulse level gauge

Accuracy

Rod probe :
+/- 2 mm (0.08 in)
Rope probe:
+/- 2 mm (0.08 in)
Coaxial probe:
+/- 2 mm (0.08 in)

Process temperature

-40...+200 В°C
(-40...+392 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...40 bar
(Vacuum...580 psi)

Max. measurement distance

Rod: 4 m (13 ft)
Min DK >1.4
Rope: 10 m (33 ft)
Min DK >1.4
Coaxial: 6 m (20 ft)
Min DK >1.4

Main wetted parts

Rod probe:
316L, PTFE, PFA
Rope probe:
316, 316L, PTFE, PFA
Coaxial probe:
316L, PTFE, PFA

Micropulse level gauge

Accuracy

Rope probe: +/- 2 mm (0.08 in)

Process temperature

40...+120 В°C
(40...+248 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...16 bar
(Vacuum...232 psi)

Max. measurement distance

Rope: 12 m (40 ft)
Min DK >1.4

Main wetted parts

Rope probe:
304, 316, 316Ti, 316L, PEEK, PPS, PA

Micropulse level gauge

Accuracy

Rod probe: +/- 2 mm (0.08 in)
Rope probe <= 15 m (49ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49ft):
+/- 10 mm (0,39 in)

Process temperature

-40...+150 В°C
(-40...+302 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...16 bar
(Vacuum...232 psi)

Max. measurement distance

Rod:
4 m (13 ft) Min DK>1.4
Rope:
20 m...25 m (66 ft...82 ft) Min DK >1.4;
25 m...30 m (82ft...98 ft) Min DK >1.6;
30 m...45 m (98ft...148 ft) Min DK>1,9

Main wetted parts

Rod probe:
316Ti, 316L, PEEK, PPS
Rope probe:
304, 316, 316Ti, 316L, PEEK, PPS, PA

Micropulse level gauge
Micropulse level gauge
Micropulse level gauge
Micropulse level gauge

Micropulse level gauge

Micropulse level gauge
Micropulse level gauge
Micropulse level gauge
Micropulse level gauge
Micropulse level gauge
Micropulse level gauge