Endress+Hauser

Choose a subcategory:
Show all categories
Measurement range

ORP: 1 500 to 1 500 mV
pH: 0 to 14

Process temperature

0 to 110 В°C (32 to 230 В°F)

Process pressure

0.8 to 14 bar (11.6 to 203 psi) absolute

Measurement range

pH 0 to 14

Process temperature

-15 to 110 В°C (5 to 230 В°F)

Process pressure

Max. 11 bar abs. at 100 В°C
(Max. 159.5 psi at 212 В°F)

Measuring cable for Memosens sensors

Memosens data cable for all sensors with Memosens plug-in head.

Measurement range

"Depending on the path length and the application the meausring range varies between: TOCeq: 0 to 400 mg/l
CODeq: 0 to 20 000 mg/l
BODeq: 0 to 5000 mg/l
SAC254: 0 to 1000 /m
TU: 0 to 800 FAU
TSS: 0 to 10 000 mg/l
NO3-N: 0 to 500 mg/l
APHA/Hazen: 0 to 500 Hazen

Process temperature

0 to 50В°C
32 to 122 В°F

Process pressure

0.5 to 10 bar abs.
7.3 to 145 psi

Measuring method

UV/VIS Absorbance at 200 to 800 nm

Accuracy

+/- 5 mm (0,2")

Process temperature

-40...+60В°C
(-40...+140В°F)

Process pressure absolute / max. overpressure limit

-1...3 bar (-14,50...43 psi)

Max. measurement distance

Standard: 8 m (26.2 ft)
With flooding protection tube: 12 m (39.4 ft)

Main wetted parts

PVDF, PBT

Accuracy

+/- 2 mm (0,08")

Process temperature

-40...+80В°C (-40...+176В°F)

Process pressure / max. overpressure limit

-1...3 bar (-14,5...43 psi)

Max. measurement distance

DN40: 15 m (49.2 ft),
DN80: 20 m (65.6 ft)

Main wetted parts

PVDF, PBT

Radar level gauge

Radar level gauge

Radar level gauge

Radar level gauge

Radar level gauge

Radar level gauge

Radar level gauge

Accuracy

+/- 2 mm (0.08 in)

Process temperature

-40...+130 В°C
(-40...+266 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...3 bar
(Vacuum...43.5 psi)

Max. measurement distance

Standard: 30 m (98 ft)
With advanced dynamics: 40 m (131 ft)

Main wetted parts

PVDF, Viton, PP, PBT

Radar level gauge

Accuracy

+/- 2 mm (0.08 in)

Process temperature

XT: -196...+280 В°C
(-321...+536 В°F)
HT: -196...+450 В°C
(-321...+842 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...160 bar
(Vacuum...2320 psi)

Max. measurement distance

Standard: 40 m (131 ft)
With "Advanced dynamics": 70 m (230 ft)

Main wetted parts

316L, Alloy C, PTFE, ceramic

Radar level gauge

Accuracy

+/- 2 mm (0.08 in)

Process temperature

-196...+200 В°C
(-321...+392 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...25 bar
(Vacuum...363 psi)

Max. measurement distance

Standard: 40 m (131 ft)
With advanced dynamics: 60 m (197 ft)

Main wetted parts

PTFE

Radar level gauge

Accuracy

+/- 6 mm (0.24 in)

Process temperature

-40...+150 В°C
(-40...+302 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...40 bar
(Vacuum...580 psi)

Max. measurement distance

Standard: 20 m (66 ft)

Main wetted parts

PTFE, PVDF

Radar level gauge

Radar level gauge

Accuracy

+/- 1 mm, custody transfer

Process temperature

-40 В°C ... 150 В°C
(-40 В°F ... 302 В°F)

Radar level gauge

Radar level gauge

Accuracy

+/- 6 mm (0.24 in)

Process temperature

-60...+400В°C
(-76...+752В°F)

Process pressure absolute / max. overpressure limit

Vacuum...160 bar
(Vacuum...2320 psi)

Max. measurement distance

Standard: 20 m (65 ft)
Planar antenna in stilling well: 38 m (125 ft)

Main wetted parts

316L

Radar level gauge

Accuracy

+/- 1 mm

Process temperature

-40В°C...200В°C
(-40В°F...392В°F)

Process pressure absolute / max. overpressure limit

Horn: Vacuum...16 bar (232 psi)
Parabolic: Vacuum...6 bar (87 psi)
Use of UNIflange: Vacuum...1 bar (14.5 psi)

Max. measurement distance

Max. measurement distance

Main wetted parts

316L

Radar level gauge

Accuracy

+/- 3 mm (0.12 in)

Process temperature

-40 В°C...+80 В°C
(-40 В°F...+176 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...3 bar
(Vacuum...43.5 psi)

Max. measurement distance

30 m (98 ft)

Main wetted parts

PP, UP

Radar level gauge

Accuracy

+/- 3 mm (0.12 in)

Process temperature

-40...+400 В°C
(-40...+752 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...16 bar
(Vacuum...232 psi)

Max. measurement distance

70 m (230 ft)

Main wetted parts

316L, PEEK, PTFE, Polyamid

Accuracy

+/- 1 mm (0.04 in)

Process temperature

-40...+130 В°C
(-40...+266 В°F)

Process pressure absolute / max. overpressure limit

Vacuum ...16 bar
(Vacuum ... 232 psi)

Max. measurement distance

50 m (164 ft)

Main wetted parts

PTFE antenna
PP or 316L process connections

Accuracy

+/- 1 mm (0.04 in)

Process temperature

-40...+200 В°C
(-40...+392 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...+25 bar
(Vacuum...+362.6 psi)

Max. measurement distance

80 m (262 ft)

Main wetted parts

PTFE or PEEK antenna,
316L threads,
PTFE cladded flanges

Accuracy

+/- 3 mm (0.12 in)

Process temperature

-40...+200 В°C
(-40...+392 В°F)

Max. measurement distance

125 m (410 ft)

Main wetted parts

PTFE, 316L
Alignment device: Alu