Endress+Hauser
Accuracy
(Pt100, -50...200 °C) <= 0,1 K
(Pt100, -58...392 °F) <= 0,18 °F
Accuracy
(Pt100, -50...200 °C) <= 0,1 K
(Pt100, -58...392 °F) <= 0,18 °F
Temperature head transmitter
HART Temperature transmitter
Temperature head transmitter
Temperature head transmitter
class A acc. to IEC 60751
Response timet50 = 1 s
t90 = 1.5 s
at 20 В°C: 50 bar (725 psi)
Operating temperature rangePT 100:
-50 В°C ...200 В°C
(-58 В°F ...392 В°F)
up to 600,00 mm (23,62'')
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class standard acc. to ASTM E230
Class 2 acc. to IEC 60584-2
t90 around 17 s
depending on configuration
depending on the configuration
Operating temperature rangeBasic PT100 TF:
-50 В°C ...200 В°C
(-58 В°F ...392 В°F)
Thermocouple:
Typ K up to 600 В°C (1.112 В°F)
up to 1.000,0 mm (39'')
Class AA acc. to IEC 60751
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class special or standard acc. to ASTM E230
Class 1 or 2 acc. to IEC 60584-2
t90 starting at < 1,5 s QuickSens
depending on configuration
depending on the configuration
Operating temperature rangePT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 QuickSensTF:
-50 В°C ...200 В°C
(-58 В°F ...392 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)
Thermoelement:
Typ K up to 1.100 В°C (2.012 В°F)
Typ J up to 800 В°C (1.472 В°F)
Typ N up to 1.100 В°C (2.012 В°F)
up to 4.500,0 mm (177'')
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class standard acc. to ASTM E230
Class 2 acc. to IEC 60584-2
t90 around 100 s
depending on configuration
depending on the configuration
Operating temperature rangeBasic PT100 TF:
-50 В°C ...200 В°C
(-58 В°F ...392 В°F)
Thermocouple:
Typ K up to 600 В°C (1.112 В°F)
up to 1.000,0 mm (39'')
Class AA acc. to IEC 60751
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class special or standard acc. to ASTM E230
Class 1 or 2 acc. to IEC 60584-2
fastest response time with thermowell t90 starting at below 10 s
depending on configuration
depending on the configuration up to 100 bar
Operating temperature rangePT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 QuickSensTF:
-50 В°C ...200 В°C
(-58 В°F ...392 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)
Thermoelement:
Typ K up to 1.100 В°C (2.012 В°F)
Typ J up to 800 В°C (1.472 В°F)
Typ N up to 1.100 В°C (2.012 В°F)
up to 4.500,0 mm (177'')
Depending on configuration up to 100 bar
Maximum standard immersion length4.500 mm (177")
Max. immersion length on request4.500 mm (177")
500 bar (7252 psi)
Depending on Configuration
1500 mm
class A acc. to IEC 60751
Response timedepending on configuration
Max. process pressure (static)at 20 В°C: 40 bar (580 psi)
Operating temperature rangePT100:
-50 В°C ... 200 В°C
(-58 В°F ... 392 В°F)
up to 15.5" (317,5mm)
others on request
Resistance thermometer
Accuracyclass A acc. to IEC 60751
class AA acc. to IEC 60751
depending on configuration
QuickSens: t90 = 1,5 s
StrongSens: t90 = 9,5 s
at 20 В°C: 40 bar (580 psi)
Operating temperature rangePT100:
-200 В°C ... 600 В°C
(-328 В°F ... 1.112 В°F)
StrongSens:
-50 В°C ... 500 В°C
(-58 В°F ... 932 В°F)
QuickSens:
-50 В°C ... 200 В°C
(-58 В°F ... 392 В°F)
class B acc. to IEC 60751
class A acc. to IEC 60751
class AA acc. to IEC 60751
depending on configuration
QuickSens: t90 = 1,5 s
StrongSens: t90 = 9,5 s
at 20 В°C: 40 bar (580 psi)
Operating temperature rangePT100 WW:
-200 В°C ... 600 В°C
(-328 В°F ... 1.112 В°F)
StrongSens:
-50 В°C ... 500 В°C
(-58 В°F ... 932 В°F)
QuickSens:
-50 В°C ... 200 В°C
(-58 В°F ... 392 В°F)
PT100 TF:
-50 В°C ... 200 В°C
48"
class 2 acc. to IEC 60584
ASTM E230 and ANSI MC 96.1
depending on configuration:
TC:
t50 = 2 s
t90 = 5 s
RTD:
t50 = 0,8s
t90 = 2s
at 20 В°C: 100 bar (1450 psi)
Operating temperature rangeType K:
-270 В°C ...1.100 В°C
(-454 В°F ...2.012 В°F)
Type J:
-210 В°C ...760 В°C
(-346 В°F ...1.382 В°F)
Type N:
-270 В°C ...1100 В°C
(-454 В°F ...2.012 В°F)
Type T:
-270 В°C ...370 В°C
(-454 В°F ...698 В°F)
up to 30.000,00 mm (1181'')
class 2 acc. to IEC 60584
ASTM E230 and ANSI MC 96.1
IEC/Class A
IEC/Class AA
depending on configuration:
TC:
t50 = 2 s
t90 = 5 s
RTD:
t50 = 0,8s
t90 = 2s
at 20 В°C: 200 bar (2900 psi)
Operating temperature rangeType K:
-270 В°C ...1.100 В°C
(-454 В°F ...2.012 В°F)
Type J:
-210 В°C ...760 В°C
(-346 В°F ...1.382 В°F)
Type N:
-270 В°C ...1100 В°C
(-454 В°F ...752 В°F)
Pt100 WW; 3mm; 316L; -200...600oC
Pt100 WW; 6mm; 316L; -200...600oC
Pt100 TF; 3mm; 316L; -50...400oC
Pt100 TF; 6mm; 316L; -50...400oC
Pt100 StrongSens; 6mm; 316L; -50...500oC
up to 30.000,00 mm (1181'')
class 1 acc. to IEC 60584
class Special ASTM E230 and ANSI MC 96.1
IEC60751 Class A
IEC60751 Class AA
depending on configuration:
TC:
t50 = 21 s
t90 = 52 s
RTD:
t50 = 42 s
t90 = 108 s
at 20 В°C: 240 bar (3481 psi)
Operating temperature rangeType K:
-270 В°C ...1.100 В°C
(-454 В°F ...2.012 В°F)
Type J:
-210 В°C ...760 В°C
(-346 В°F ...1.382 В°F)
Type N:
-270 В°C ...1100 В°C
(-454 В°F ...2.012 В°F)
Pt100 WW; 3mm; 316L; -200...600oC
Pt100 TF; 3mm; 316L; -50...400oC
up to 15.000,00 mm (590'')
class 1 acc. to IEC 60584
class Special ASTM E230 and ANSI MC 96.1
IEC60751 Class A
IEC60751 Class AA
depending on configuration:
TC:
t50 = 21 s
t90 = 52 s
RTD:
t50 = 42 s
t90 = 108 s
at 20 В°C: 240 bar (3481 psi)
Operating temperature rangeType K:
-270 В°C ...1.100 В°C
(-454 В°F ...2.012 В°F)
Type J:
-210 В°C ...760 В°C
(-346 В°F ...1.382 В°F)
Type N:
-270 В°C ...1100 В°C
(-454 В°F ...2.012 В°F)
Pt100 WW; 3mm; 316L; -200...600oC
Pt100 TF; 3mm; 316L; -50...400oC
up to 15.000,00 mm (590'')
class 2 acc. to IEC 60584
ASTM E230 and ANSI MC 96.1
t50 = 3 s
t90 = 9 s
at 20 В°C: 90 bar (1305 psi)
Operating temperature rangeType K:
-270 В°C ...1.100 В°C
(-454 В°F ...2.012 В°F)
Type J:
-210 В°C ...760 В°C
(-346 В°F ...1.382 В°F)
Type N:
-270 В°C ...1100 В°C
(-454 В°F ...2.012 В°F
Type E:
-40 В°C ...870 В°C
(-40 В°F ...752 В°F)
up to 13.000,00 mm (511,81'')
class 1 acc. to IEC 60584
class 2 acc. to IEC 60584
class Special ASTM E230 and ANSI MC 96.1
IEC60751 Class A
IEC60751 Class AA
TC
t50 = 1 s
t90 = 2 s
RTD
t50 = 3 s
t90 = 6 s
at 20 В°C: 40 bar (580 psi)
Operating temperature rangeType K:
-270 В°C ...800 В°C
(-454 В°F ...1.472 В°F)
Type J:
-210 В°C ...520 В°C
(-346 В°F ...968 В°F)
Pt100 WW; 3mm; 316L; -200...600oC
Pt100 StrongSens; 6mm; 316L; -50...500oC
Pt100 TF; 3mm; 316L; -50...400oC
up to 60.000,00 mm (2.360'')
t50 = 2.5 s
t90 = 5.4 s
at 20 В°C: 40 bar (580 psi)
Operating temperature rangePt 100:
-40 В°C to 160 В°C
(-40 В°F to 320 В°F)
up to 900.00 mm (35.4'')
t50 = 2,5 s
t90 =9,5s
at 20 В°C: 40 bar (580 psi)
Operating temperature rangePT 100:
-40 В°C ...160 В°C
(-40 В°F ...320 В°F)
up to 28'' (711 mm)
others on request
40 bar (580 psi)
Maximum standard immersion length4.000 mm (157,48")
Max. immersion length on requestNot defined
40 bar (580 psi)
Maximum standard immersion length48" (1.219 mm)
Concentration
Dew Point
Cell Pressure
Cell Temperature
ATEX / IECEx Zone 1
UKEx Zone 1
CSA Class I, Division 1
CSA Class I, Zone 1