Endress+Hauser
Vibrating level gauge
Process temperature-60 В°C...+280 В°C
(-76 В°F...+540 В°F)
(300В°C / 572В°F, 50h cumulated)
Vacuum...100 bar
(Vacuum...1450 bar)
0.5g/cmВі (0.4g/cmВі optional)
Vibronic point level detection. FailSafe overfill prevention
Process temperature-60В°C...+280В°C
(-76В°F...+540В°F)
Vacuum...100 bar
(1450 psi)
Density from 0.4 g/cm3
(0.4 SGU)
Vibronic point level detection
Process temperature-60В°C...+280В°C
(-76В°F...+540В°F)
Vacuum...100 bar
(1450 psi)
Density from 0.4 g/cm3
(0.4 SGU)
Vibronic point level detection
Process temperature50В°C...+150В°C
(58В°F...+300В°F)
Vacuum...40 bar
(580 psi)
Density from 0.4 g/cm3
(0.4 SGU)
Vibrating level gauge
Vibrating level gauge
Vibrating level gauge
Standard:
-20 ... 100В°C
Cleaning:
-20 ... 135В°C for 1h
-4 ... 275F for 1h
Vacuum ... 16 bar
Vacuum ....232 psi
Conductive point level detection
Process temperature-40 В°C ... 100 В°C
(-40 В°F ... 212 В°F)
Vacuum ... 10 bar
(Vacuum ... 145 psi)
10 ВµS/cm
Conductive point level detection
Process temperature-40 В°C ... 70 В°C
(-40 В°F ... 158 В°F)
Vacuum ... 10 bar
(Vacuum ... 145 psi)
10 ВµS/cm
Level converter
Standard:
-20 ... 100В°C
Cleaning:
-20 ... 150В°C for 1h
( -4 ... 302В°F for 1h)
Vacuum ... 25 bar
(Vacuum ... 362,5 psi)
Water sampler
FunctionsPortable sampler
Suction height8 m (26.25 ft) Suction height
CabinetPlastic LDDPE
Stationary sampler
Suction height8m (26.25ft)
CabinetPlastic ASA+PC
Process temperatureSample temperature 2 to 50В°C (36 to 122В°F)
Process pressuremax 0,8bar ( 11.6PSI)
Water sampler
FunctionsStationary sampler
Suction height6 m (19.69 ft) suction height
8 m (26.25 ft) suction height
Plastic PS
Plastic ASA+PC
Stainless Steel V2A
Stainless Steel V4A
Sample temperature: 2 to 50 В°C
(36 to 122 В°F)
Max. 0.8 bar
(Max. 11.6 psi)
Free chlorine transmitter
InputChor / Chlordioxide and pH/ORP Sensor.
Output / communication- Chlor/Chlordioxid, pH, Temperatur : 0/4-20mA- Profibus- Hart + 0/4-20mA
Free chlorine transmitter
InputChorine / Chlordioxide and pH/ORP Sensor.
Output / communication- Chlorine/Chlordioxid, pH, Temperature : 0/4-20mA- Profibus- Hart + 0/4-20mA
Liquid Conductivity Sensor
Input1-channel transmitter
Output / communication0/4-20 mA, Hart, Profibus.
Ingres protectionIP65
One-channel transmitter
Output / communication0/4-20mA, Hart, Profibus.
Ingres protectionIP65
Liquid Oxygen Sensor
Input1-channel transmitter
Output / communication0/4-20mA, Hart, Profibus.
Liquid Oxygen Sensor
Input1-channel transmitter.
Output / communication0/4-20mA, Hart, Profibus.
Liquid PH and ORP analysis sensor
InputOne-channel-transmitter
Output / communication0/4-20 mA, Hart, Profibus.
Ingres protectionIP65
One-channel-transmitter
Output / communication0/4-20mA, Hart, Profibus.
Ingres protectionNo
Liquid Oxygen Sensor
Liquid Oxygen Sensor
Turbidity Analysis Sensor
Conductivity:
0 ВµS/ cm...100 mS/ cm
Build-up thickness:
0 mm...10 mm
-20В°...+100В°C
(-4В°F...+212В°F)
+150В°C (+302В°F) for 1h
Vacuum...25 bar
(Vacuum...362.5 psi)
Capacitive- conductive