Endress+Hauser

Choose a subcategory:
Show all categories

Vibrating level gauge

Process temperature

-60 В°C...+280 В°C
(-76 В°F...+540 В°F)
(300В°C / 572В°F, 50h cumulated)

Process pressure absolute / max. overpressure limit

Vacuum...100 bar
(Vacuum...1450 bar)

Min. density of medium

0.5g/cmВі (0.4g/cmВі optional)

Vibronic point level detection. FailSafe overfill prevention

Process temperature

-60В°C...+280В°C
(-76В°F...+540В°F)

Process pressure absolute / max. overpressure limit

Vacuum...100 bar
(1450 psi)

Min. density of medium

Density from 0.4 g/cm3
(0.4 SGU)

Vibronic point level detection

Process temperature

-60В°C...+280В°C
(-76В°F...+540В°F)

Process pressure absolute / max. overpressure limit

Vacuum...100 bar
(1450 psi)

Min. density of medium

Density from 0.4 g/cm3
(0.4 SGU)

Vibronic point level detection

Process temperature

50В°C...+150В°C
(58В°F...+300В°F)

Process pressure absolute / max. overpressure limit

Vacuum...40 bar
(580 psi)

Min. density of medium

Density from 0.4 g/cm3
(0.4 SGU)

Vibrating level gauge

Vibrating level gauge

Vibrating level gauge

Process temperature

Standard:
-20 ... 100В°C
Cleaning:
-20 ... 135В°C for 1h
-4 ... 275F for 1h

Process pressure absolute / max. overpressure limit

Vacuum ... 16 bar
Vacuum ....232 psi

Conductive point level detection

Process temperature

-40 В°C ... 100 В°C
(-40 В°F ... 212 В°F)

Process pressure absolute / max. overpressure limit

Vacuum ... 10 bar
(Vacuum ... 145 psi)

Min. conductivity of medium

10 ВµS/cm

Conductive point level detection

Process temperature

-40 В°C ... 70 В°C
(-40 В°F ... 158 В°F)

Process pressure absolute / max. overpressure limit

Vacuum ... 10 bar
(Vacuum ... 145 psi)

Min. conductivity of medium

10 ВµS/cm

Process temperature

Standard:
-20 ... 100В°C
Cleaning:
-20 ... 150В°C for 1h
( -4 ... 302В°F for 1h)

Process pressure absolute / max. overpressure limit

Vacuum ... 25 bar
(Vacuum ... 362,5 psi)

Water sampler

Functions

Portable sampler

Suction height

8 m (26.25 ft) Suction height

Cabinet

Plastic LDDPE

Functions

Stationary sampler

Suction height

8m (26.25ft)

Cabinet

Plastic ASA+PC

Process temperature

Sample temperature 2 to 50В°C (36 to 122В°F)

Process pressure

max 0,8bar ( 11.6PSI)

Water sampler

Functions

Stationary sampler

Suction height

6 m (19.69 ft) suction height
8 m (26.25 ft) suction height

Cabinet

Plastic PS
Plastic ASA+PC
Stainless Steel V2A
Stainless Steel V4A

Process temperature

Sample temperature: 2 to 50 В°C
(36 to 122 В°F)

Process pressure

Max. 0.8 bar
(Max. 11.6 psi)

Free chlorine transmitter

Input

Chor / Chlordioxide and pH/ORP Sensor.

Output / communication

- Chlor/Chlordioxid, pH, Temperatur : 0/4-20mA- Profibus- Hart + 0/4-20mA

Free chlorine transmitter

Input

Chorine / Chlordioxide and pH/ORP Sensor.

Output / communication

- Chlorine/Chlordioxid, pH, Temperature : 0/4-20mA- Profibus- Hart + 0/4-20mA

Liquid Conductivity Sensor

Input

1-channel transmitter

Output / communication

0/4-20 mA, Hart, Profibus.

Ingres protection

IP65

Input

One-channel transmitter

Output / communication

0/4-20mA, Hart, Profibus.

Ingres protection

IP65

Liquid Oxygen Sensor

Input

1-channel transmitter

Output / communication

0/4-20mA, Hart, Profibus.

Liquid Oxygen Sensor

Input

1-channel transmitter.

Output / communication

0/4-20mA, Hart, Profibus.

Liquid PH and ORP analysis sensor

Input

One-channel-transmitter

Output / communication

0/4-20 mA, Hart, Profibus.

Ingres protection

IP65

Input

One-channel-transmitter

Output / communication

0/4-20mA, Hart, Profibus.

Ingres protection

No

Liquid Oxygen Sensor

Liquid Oxygen Sensor

Turbidity Analysis Sensor

Measurement range

Conductivity:
0 ВµS/ cm...100 mS/ cm
Build-up thickness:
0 mm...10 mm

Process temperature

-20В°...+100В°C
(-4В°F...+212В°F)
+150В°C (+302В°F) for 1h

Process pressure

Vacuum...25 bar
(Vacuum...362.5 psi)

Measuring method

Capacitive- conductive