Endress+Hauser

Choose a subcategory:
Show all categories
Max. measurement error

Mass flow (liquid): В±0.15 %
Volume flow (liquid): В±0.15 %
(Reference condition)

Measuring range

0 to 18 000 kg/h (0 to 660 lb/min)

Medium temperature range

196 to +125 В°C (320 to +257 В°F)

Max. process pressure

PN 40, Class 300

Wetted materials

Measuring tubes: 1.4539 (904L)
Connection: 1.4404 (316/316L)

Max. measurement error

Mass flow (liquid): В±0.2 %
Volume flow (liquid): В±0.3 %

Measuring range

0 to 45 000 kg/h (0 to 1650 lb/min)

Medium temperature range

40 to +125 В°C (40 to +257 В°F)

Max. process pressure

PN 40, Class 300, 63K

Wetted materials

Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)

Max. measurement error

Mass flow (liquid): В±0.20 %
Volume flow (liquid): В±0.30 %

Measuring range

0 to 70 000 kg/h (0 to 2570 lb/min)

Medium temperature range

50 to +125 В°C (58 to +257 В°F)

Max. process pressure

PN 40, Class 300

Wetted materials

Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)

Process temperature

-200 В°C ... 200 В°C
(-328 В°F ... 392 В°F)

Process pressure absolute / max. overpressure limit

1bar abs...24.5 bar abs
15 psi...355.25 psi

Accuracy

up to В±2mm (+/- 0.08")

Max. measurement error

2%

Measuring range

0 to 56'550 m3/h

Medium temperature range

-20 to +120В°C
(-4 to +248В°F)

Max. process pressure

0 to 16 bar abs

Wetted materials

1.4435/316L

Electromagnetic flowmeter
Measure, calibrate, and document with one single tool for Memosens sensors.
Liquid PH and ORP analysis sensor
Measured value simulator for Memosens measuring points.

Liquid PH and ORP analysis sensor

All-round checker for Memosens measuring points in all industries.
Input

20 analog (max) (U, I, TC, RTD, frequency, pulse)
20 HART (max) (HART, 4...20mA)
14 digital (max) (control, event and counting inputs)

Output

12 relays (max)
2 analog (max) (I, pulse)
1 transmitter power supply

Display

TFT 7" colour graphic display
TFT 7" colour graphic display with touch panel

Storage/Recording

internal memory
SD card
USB flash drive

Calculations

Mass/heat quantity
heat quantity difference

Measurement range

0.1 to 10 mg/l total chlorine

Process temperature

5 to 45 В°C
(41 to 113 В°F)

Process pressure

1 to 4 bar (14.5 to 58 psi)

Measuring method

Total chlorine consists of free chlorine (HOCl, OCl-) and bound chlorine (chloramines)
All components are reduced at the working electrode
Almost pH independent

Measurement range

Trace: 0 to 5 mg/l ClO2
Standard: 0 to 20 mg/l ClO2
High: 0 to 200 mg/l ClO2

Process temperature

0 to 55 В°C , non-freezing
(32 to 130 В°F)

Process pressure

Max. 2 bar abs
(Max. 29 psi abs)

Measurement range

Trace: 0 to 5 mg/l HOCl
Standard: 0 to 20 mg/l HOCl
High: 0 to 200 mg/l HOCl

Process temperature

0 to 55 В°C (32 to 130 В°F), non-freezing

Process pressure

Max. 1 bar (max. 14.5 psi)

Measuring method

Closed, membrane covered measuring cell
Reduction of free chlorine at the cathode

Measurement range

Trace: 0 ... 5 mg/l HOBr
Standard: 0 ... 20 mg/l HOBr
High: 0 ... 200 mg/l HOBr

Process temperature

+0...55 В°C (32 ... 130В°F), non-freezing

Process pressure

Max. 1 bar (max. 14.5 psi)

Measurement range

0 to 2 mg/l

Process temperature

+0 to 45 В°C (32 to 110 В°F), non freezing

Process pressure

1 bar (14.5 psi), 2 bar (29 psi) absolute

Measuring method

- closed 2 electrode system
- conversion of ozone into a signal current in nA
- signal current is proportional to the concentration of ozone
- the measurement is not pH dependent

Measurement range

5 ОјS/cm to 200 mS/cm

Process temperature

0 to 100 В°C (32 to 212 В°F)

Process pressure

1 bar, not intended for continues measurment in process

Measurement range

k=0,01: 0.04 to 20 ВµS/cm
k=0,1: 0.10 to 200 ВµS/cm

Process temperature

Threaded with fixed cable:
-20 to 100 В°C (-4 to 212 В°F)
Threaded with plug-in head:
-20 to 120 В°C (-4 to 248 В°F)
Sterilization: max. 140 В°C (284 В°F) for 30 minutes

Process pressure

13 bar at 20 В°C (188 psi at 68 В°F) absolute
1 bar at 120 В°C (14 psi at 248 В°F) absolute

Measurement range

k=0,1: 0,04 to 500 ВµS/cm

Process temperature

-5 to 120 В°C (23 to 248 В°F)
For Sterilizsation: max. 150 В°C at 5 bar
(Max. 302 В°F at 73 psi)

Process pressure

13 bar at 20 В°C (188 psi at 68 В°F)
9 bar at 120 В°C (130 psi at 248 В°F)

Measurement range

k=1: 10 ВµS/cm to 20 mS/cm

Process temperature

-20 to 135 В°C at 3.5 bar abs
(-4 to 275 В°F at 50 psi)

Process pressure

17 bar abs at 20 В°C
(246 psi at 68 В°F)

Measurement range

1 ВµS/cm to 500 mS/cm

Process temperature

-5 to 120 В°C (23 to 248 В°F)
Sterilization: max. 140 В°C at 6 bar for max. 45 min
(Max. 284 В°F at 87 psi for max. 45 min)

Process pressure

17 bar abs at 20 В°C (247 psi at 68 В°F)
9 bar abs at 120 В°C (131 psi at 248 В°F)

Measurement range

1 ВµS/cm to 500 mS/cm

Process temperature

-5 to 120 В°C (23 to 248 В°F)
Sterilization: max. 140 В°C at 6 bar for max. 45 min
(Max. 284 В°F at 87 psi for max. 45 min)

Process pressure

17 bar abs at 20 В°C (247 psi at 68 В°F)
9 bar abs at 120 В°C (131 psi at 248 В°F)

Measurement range

0 to 200 %SAT

Process temperature

5 to +60 ЛљC (23 to 140 ЛљF)

Process pressure

1 bar, not intended for continues measurment in process