Endress+Hauser

Choose a subcategory:
Show all categories

Digital pH electrode for measuring ORP

Measurement range

pH 0 to 14

Process temperature

0 to 135 В°C (32 to 275 В°F)

Process pressure

1 to 11 bar abs (15 to 160 psi)

Analog pH electrode for ORP measurement

Measurement range

-1500 mV - +1500 mV

Process temperature

-15В°C - 130В°C

Process pressure

max. 8bar

Digital pH electrode for measuring ORP

Measurement range

-1500 mV - +1500 mV

Process temperature

-15В°C - 130В°C

Process pressure

max. 8bar

Measurement range

pH -2 to 14

Process temperature

0 to 140 В°C
(32 to 280 В°F)

Process pressure

0 to 7 bar abs
(0 to 101.5 psi)

Measuring cell

+100 mbar....+40 bar
(+1.5 psi....600 psi)

Measuring cell

+400 mbar....+400 bar
(+6 psi...+6000 psi)

Measuring cell

+400 mbar....+40 bar
(+6 psi....+600 psi)

Limit pressure switch

Limit pressure switch

Limit pressure switch

Measurement range

pH 1 - 12

Process temperature

0 - 80 C (32 - 176 F)

Process pressure

1 - 4 bar abs (15 - 60 psi)

Cleaning injector for spray cleaning and retractable assemblies.

Free chlorine concentration sensor

Paper recorder z-fold paper 16m. Universal input, U,I,TC,RTD. Channel display + status display. Meas. value recording, analog.

Process temperature

max. 80В°C (176В°F)

Process pressure

For manual assembly operation : max 2bar (29psi)
Medium pressure : max. 10bar (145psi)

Unit for retractable assemblies in water & wastewater, food, paper and primaries.

Retractable assembly for measuring pH and ORP

Process temperature

-15 to 130 В°C (5 to 266 В°F)

Process pressure

Max. 12 bar at 100 В°C (175 psi at 212 В°F)

Retractable assembly for measuring pH and ORP

Process temperature

0 to 140 В°C (32 to 284 В°F)

Process pressure

0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation
0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation

Retractable assembly for measuring pH and ORP

Process temperature

PA pressure cylinder (manually only):
Max. 80 В°C (176 В°F)
Stainless steel pressure cylinder: up to 100В°C (212 В°F) with continuous operation up to 6 bar (87 psi)

Process pressure

PA pressure cylinder: Max. 6 bar (87 psi)
Stainless steel pressure cylinder: Max. 10 bar (145 psi)
Pneumatic outlet safety seal:
6 bar at 100 В°C (87 psi at 212 В°F)

Retractable assembly for measuring pH and ORP

Process temperature

PA version: max. 80 В°C (max. 176 В°F)
Stainless steel pressure cylinder: max. 120 В°C (248 В°F)

Process pressure

PA pressure cylinder: max. 6 bar (87 psi)
Stainless steel pressure cylinder: max. 10 bar (145 psi) at 40 В°C (104 В°F)

Process temperature

-10 to 140 В°C (14 to 284 В°F) for all materials except PVDF and conductive PVDF
-10 to 100 / 90 В°C (14 to 212 / 194 В°F) for PVDF and conductive PVDF materials

Process pressure

Stainless steel, Alloy C22, PEEK:
16 bar up to 140 В°C (232 psi up to 284 В°F)
PVDF, conductive PVDF:
Basic version: 16 bar up to 100 В°C (232 psi up to 212 В°F)
Immersion chamber version:
4 bar to 90 В°C (58 psi up to 194 В°F)

Process temperature

-10 to 140 В°C (14 to 284 В°F)

Process pressure

Pneumatic drive: 16 bar up to 140 В°C (232 psi up to 284 В°F)
Manual drive: 8 bar up to 140 В°C (116 psi up to 284 В°F)

Retractable assembly for turbidity sensors

Process temperature

0 to 85 В°C (32 to 185 В°F)

Process pressure

For manual assembly operation : max 2bar (29psi)
Medium pressure : max. 10bar (145psi)

Retractable assembly for measuring pH and ORP

Retractable assembly for measuring pH and ORP

Retractable assembly for measuring pH and ORP

Retractable assembly, pH-/ORP. Stopcock locking system.

Max. measurement error

Mass flow: В±0.5 % of batch

Measuring range

0 to 150 kg/min (0 to 330 lb/min)

Medium temperature range

50 to +125 В°C (58 to +257 В°F)

Max. process pressure

350 bar (5080 psi)

Wetted materials

Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316)

Coriolis flowmeter

Max. measurement error

Mass flow: В±0.5 % of batch

Measuring range

0 to 150 kg/min (0 to 330 lb/min)

Medium temperature range

50 to +125 В°C (58 to +257 В°F)

Max. process pressure

350 bar (5080 psi)

Wetted materials

Mesuring tube: 1.4435 (316L)
Connection: 1.4404 (316/316L)