Endress+Hauser
Max. measurement error
Mass flow: В±0.5 % of batch
Measuring range
0 to 150 kg/min (0 to 330 lb/min)
Medium temperature range
50 to +125 В°C (58 to +257 В°F)
Max. process pressure
350 bar (5080 psi)
Wetted materials
Mesuring tube: 1.4435 (316L)
Connection: 1.4404 (316/316L)
Max. measurement error
Mass flow: В±0.5 % of batch
Measuring range
0 to 150 kg/min (0 to 330 lb/min)
Medium temperature range
50 to +150 В°C (58 to +302 В°F)
Max. process pressure
350 bar (5080 psi)
Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4404 (316)
Data interface
InputUSB signal as per USB specification.
OutputConnects HART field devices with the USB interface of a laptop
Liquid Conductivity Sensor
Measurement rangek=0.01: 0 to 20 ВµS/cm
k= 0.1: 0 to 200 ВµS/cm
-30 to 160 В°C (-22 to 320 В°F)
Process pressureMax. 40 bar up to 100 В°C (max. 580 psi up to 212 В°F) without CLA 751 flow chamber
Max. 12 bar up to 150 В°C (max. 174 psi up to 302 В°F) with CLA 751 flow chamber
Liquid Conductivity Sensor
Measurement rangek=0,01: 0-20,0 ВµS/cm
k=0,1: 0-200,0 ВµS/cm
max. 250 В°C (482 В°F)
Process pressuremax. 40 bar (580 psi)
Liquid Conductivity Sensor
Measurement rangek=0,01: 0-20 ВµS/cm
k=0,1: 0-200 ВµS/cm
max. 130В°C (150В°C / 30 min.)
(max. 266В°F (302В°F/30 min.)
max. 12 bar at 20В°C
(174 psi at 68В°F)
k=0,01: 0.04 to 20 ВµS/cm
k=0,1: 0.10 to 200 ВµS/cm
Threaded with fixed cable:
-20 to 100 В°C (-4 to 212 В°F)
Threaded with plug-in head:
-20 to 120 В°C (-4 to 248 В°F)
Sterilization: max. 140 В°C (284 В°F) for 30 minutes
13 bar at 20 В°C (188 psi at 68 В°F)
1 bar at 120 В°C (14 psi at 248 В°F)
Liquid Conductivity Sensor
Measurement rangek=0,1: 0,04ВµS/cm - 500ВµS/cm
Process temperatureMax. 120В°C (150В°C/30 min)
max. 248В°F (302В°F/30 min.)
max. 12 bar at 20В°C
max.174 psi at 68В°F
k=0,1: 0,04 to 500 ВµS/cm
Process temperature-5 to 120 В°C (23 to 248 В°F)
For Sterilizsation: max. 150 В°C at 5 bar
(Max. 302 В°F at 73 psi)
13 bar at 20 В°C (188 psi at 68 В°F)
9 bar at 120 В°C (130 psi at 248 В°F)
Liquid Conductivity Sensor
Measurement rangek=0,01: 0-20 ВµS/cm
k=0,1: 0-200 ВµS/cm
max. 60В°C
max. 140В°F
max. 6 bar at 20В°C
(max.87 psi at 68В°F)
k=1: 10,0 ВµS/cm - 20,0 mS/cm
Process temperaturemax. 135В°C
(max. 275В°F)
max. 16 bar at 20°С
(max. 232psi at 68В°F)
k=1: 10 ВµS/cm to 20 mS/cm
Process temperature-20 to 135 В°C at 3.5 bar abs
(-4 to 275 В°F at 50 psi)
17 bar abs at 20 В°C
(246 psi at 68 В°F)
0 to 135В°C (32 to 275 В°F)
Process pressuremax. 11 bar abs. (159 psi abs.) at 25В°C (77В°F)
Max. measurement error
Mass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.5 %
Density (liquid): В±0.0005 g/cm3
Measuring range
0 to 1000 kg/h (0 to 37 lb/min)
Medium temperature range
50 to +200 В°C (58 to +392 В°F)
Max. process pressure
PN 40, Class 300, 10K, 400 bar (5800 psi)
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
Max. measurement error
Mass flow (liquid): В±0.1 %
Volume flow (liquid): В±0.1 %
Mass flow (gas): В±0.5 %
Density (liquid): В±0.0005 g/cm3
Measuring range
0 to 1000 kg/h (0 to 37 lb/min)
Medium temperature range
50 to +200 В°C (58 to +392 В°F)
Max. process pressure
PN 40, Class 300, 10K, 400 bar (5800 psi)
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
max.130В°C
266В°F
Stainless steel: max. 16 bar; PVDF: max 4 bar
Universal hanger for rebar