Open circuit voltage/short-circuit currentapprox. 10 V DC / approx. 8 mA
Ambient temperature-20 ... 60 В°C (-4 ... 140 В°F)
Pulse/Pause ratiomin. 100 µs / min. 100 µs
IECEx approvalIECEx BAS 13.0046
IECEx CML 19.0147X
Rated current35 ... 25 mA
EU-type examination certificateBASEEFA 13 ATEX 0080
Ripple≤ 10 %
Labelingspace for labeling at the front
ConnectionPower Rail or terminals 9+, 10-
Protection against electrical shockIEC 61010-1:2010
Degree of protectionIEC 60529:2001
Display elementsLEDs
Collective error messagePower Rail
Configurationvia DIP switches
Connection sidecontrol side
Input/Outputreinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
Line fault detectionbreakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA
Degree of protectionIP20
Optional accessories- power feed module KFD2-EB2(.R4A.B)(.SP)
- universal power rail UPR-03(-M)(-S)
- profile rail K-DUCT-BU(-UPR-03)
Connection sidefield side
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Switching frequency≤ 5 kHz
Power dissipation≤ 750 mW
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Electromagnetic compatibilityNE 21:2011 , EN 61326-3-2:2008
Rated voltage19 ... 30 V DC with external resistance > 2 kΩ, e. g. 16-channel ProSafe DI card SDV144 from Yokogawa
Rated voltage19 ... 30 V DC
Safety Integrity Level (SIL)SIL 2
CertificateCML 19 ATEX 4410 X
Control elementsDIP-switch
Dimensions12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2
Switching point/switching hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Output I, IIsignal or error message, passive transistor output (resistive)
0-signal: 33 kΩ В± 5 % + voltage drop 6.5 V В± 0.5 V
1-signal: voltage drop 6.5 V В± 0.5 V
fault: > 100 kΩ
Input/power supplyreinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
Connectionoutput I: terminals 5, 6 ; output II: terminals 7, 8
Massapprox. 100 g
Connectionscrew terminals
Output/Outputbasic insulation according to EN 50178, rated insulation voltage 50 Veff
Output/power supplybasic insulation according to EN 50178, rated insulation voltage 50 Veff
Connectionterminals 1+, 2-; 3+, 4-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
InputEN 60947-5-6:2000
Response time≤ 200 µs
Signal typeDigital Input