IN STOCK!!!

Tether arm T3

  • Accessory for Baumer 11076547
  • Prevents overload of the bearing force
  • Flexible mounting point orientation
  • Adjustable length
  • For bolt 1/4”

Absolute encoders AMG 81

  • For replacement of "PY" or "BC" style tachogenerators
  • Low response time
  • Open circuit voltage 20...100 mV per rpm
  • Very high resistance to shock
  • High signal quality due to patented LongLife technology
  • Recognition of sense of rotation possible via control
  • CSA / C / US approved
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.120 mA (5 VDC, w/o load)
70 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Interface12 parallel outputs
Operating temperature-20...+85 °C
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.60 mA (5 VDC, w/o load)
40 mA (24 VDC, w/o load)
Pulses per revolution4096...320000
Operating temperature-20...+85 °C
Voltage supply5 VDC ±5 %
Consumption typ.100 mA (5 VDC, w/o load)
Sinewave cycles per turn1000...5000
Operating temperature-20...+85 °C
Price on Request
One click request
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.80 mA (5 VDC, w/o load)
60 mA (24 VDC, w/o load)
Pulses per revolution20...5000
Operating temperature-20...+85 °C
Voltage supply5 VDC ±5 %
Consumption typ.100 mA (5 VDC, w/o load)
Sinewave cycles per turn1000...5000
Operating temperature-20...+85 °C
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.80 mA (5 VDC, w/o load)
60 mA (24 VDC, w/o load)
Pulses per revolution10000...320000
Operating temperature-20...+85 °C
Voltage supply10...30 VDC
Consumption w/o load≤80 mA (24 VDC)
Initializing time typ.500 ms after power on
Operating temperature-40...+85 °C (see general informations)
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Operating temperature-20...+85 °C
Voltage supply10...30 VDC
Consumption w/o load≤200 mA (24 VDC)
Initializing time≤250 ms after power on
Operating temperature-40...+85 °C (see general informations)
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption w/o load≤150 mA (5 VDC)
≤60 mA (24 VDC)
Initializing time typ.170 ms after power on
Operating temperature-40...+85 °C (see general informations)
InputsSSI clock: Linereceiver RS422
Zero setting input
Voltage supply10...30 VDC
Consumption typ.50 mA (24 VDC, w/o load)
Initializing time≤170 ms after power on
Operating temperature-40...+85 °C
InputsSSI clock
Zero setting input
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.100 mA (5 VDC, w/o load)
50 mA (24 VDC, w/o load)
Initializing time typ.70 ms after power on
Operating temperature-20...+85 °C
InputsSSI clock
Zero setting input
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.100 mA (5 VDC, w/o load)
50 mA (24 VDC, w/o load)
Initializing time typ.70 ms after power on
Operating temperature-40...+65 °C
InputsSSI clock
Zero setting input
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.100 mA (5 VDC, w/o load)
50 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Operating temperature-20...+85 °C
InputsSSI clock
Zero setting input
Voltage supply8...30 VDC
Reverse polarity protectionYes
Short-circuit proofYes
Operating temperature-40...+85 °C
Voltage supply10...30 VDC
Consumption w/o load≤80 mA (24 VDC)
Initializing time typ.500 ms after power on
Operating temperature-40...+85 °C (see general informations)
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Initializing time typ.500 ms after power on
Operating temperature-20...+65 °C
Voltage supply10...30 VDC
Consumption w/o load≤200 mA (24 VDC)
Initializing time≤250 ms after power on
Operating temperature-40...+85 °C (see general informations)
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Operating temperature-40...+85 °C
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Operating temperature-40...+85 °C
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption w/o load≤150 mA (5 VDC)
≤60 mA (24 VDC)
Initializing time typ.170 ms after power on
Operating temperature-40...+85 °C (see general informations)
InputsSSI clock: Linereceiver RS422
Zero setting input
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.100 mA (5 VDC, w/o load)
50 mA (24 VDC, w/o load)
Initializing time typ.70 ms after power on
Operating temperature-20...+85 °C
InputsSSI clock
Zero setting input
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Operating temperature-20...+85 °C
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Operating temperature-20...+85 °C
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.100 mA (5 VDC, w/o load)
50 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Operating temperature-20...+85 °C
InputsSSI clock
Zero setting input
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Initializing time typ.500 ms after power on
Operating temperature-20...+65 °C
Voltage supply10...30 VDC
Consumption w/o load≤200 mA (24 VDC)
Initializing time≤250 ms after power on
Operating temperature-40...+85 °C (see general informations)