Endress+Hauser Liquid analysis

Analyzer for continuous measurement of UV absorbance

Sensor for in-situ determination of organic content in aqueous solutions. No reagents needed, measures directly in the sample.

Photometric UV analyzer
Max. measurement error

Density: В±0.01g/cmВі
Temperature: В±0.5K
Sound velocity: 2m/s

Measuring range

Concentration According to concentration app data sheet, maximum 0 to 100 %
Sound velocity 600 to 2000 m/s
Temperature concentration app data sheet, maximum 0 to +100 В°C (32 to +212 В°F)
Density 0.7 to 1.5 g/cmВі

Medium temperature range

0 to 100 В°C (32 to 212 В°F)

Max. process pressure

max. 16 bar at 20 В°C (232 psi at 68 В°F)

Max. measurement error

Density: В±0.01g/cmВі
Temperature: В±0.5K
Sound velocity: 2m/s

Measuring range

Concentration According to concentration app data sheet, maximum 0 to 100 %
Sound velocity 600 to 2000 m/s
Temperature concentration app data sheet, maximum 0 to +100 В°C (32 to +212 В°F)
Density 0.7 to 1.5 g/cmВі

Medium temperature range

0 to 120В°C (32 to 248 В°F)

Max. process pressure

max. 16 bar at 20 В°C (232 psi at 68 В°F)

Max. measurement error

Density: В±0.01g/cmВі
Temperature: В±0.5K
Sound velocity: 2m/s

Measuring range

Concentration According to concentration app data sheet, maximum 0 to 100 %
Sound velocity 600 to 2000 m/s
Temperature concentration app data sheet, maximum 0 to +100 В°C (32 to +212 В°F)
Density 0.7 to 1.5 g/cmВі

Medium temperature range

0 to 100 В°C (32 to 212 В°F)

Max. process pressure

max. 16 bar at 20 В°C (232 psi at 68 В°F)

Max. measurement error

Density: В±0.01g/cmВі
Temperature: В±0.5K
Sound velocity: 2m/s

Measuring range

Concentration According to concentration app data sheet, maximum 0 to 100 %
Sound velocity 600 to 2000 m/s
Temperature concentration app data sheet, maximum 0 to +100 В°C (32 to +212 В°F)
Density 0.7 to 1.5 g/cmВі

Medium temperature range

0 to 100 В°C (32 to 212 В°F)

Nitrate Measurement Analyzer
Liquid PH and ORP analysis sensor
Liquid PH and ORP analysis sensor
Liquid PH and ORP analysis sensor
Liquid PH and ORP analysis sensor
Liquid PH and ORP analysis sensor
Liquid PH and ORP analysis sensor
Liquid PH and ORP analysis sensor
Liquid PH and ORP analysis sensor
Turbidity Analysis Sensor
Turbidity Analysis Sensor
Turbidity Analysis Sensor
Turbidity Analysis Sensor
Turbidity Analysis Sensor
Turbidity Analysis Sensor

Turbidity Analysis Sensor

Measurement range

40 to 4 000 FAU
0 to 60 g/L suspended solids
0 to 10 OD

Process temperature

Process temperature -20 to 85 В°C (-4 to 185 В°F)
Ambient temperature -20 to 60 В°C (-4 to 140 В°F)

Process pressure

0.5 to 4.5 bar (7.3 to 65.3 psi) absolute

Turbidity Analysis Sensor
Measurement range

0.000 to 4000 FNU

Process temperature

Stainless steel version: -20 to 85 В°C (0 to 185 В°F)
Plastic version: -20 to 60В°C (-4 to 140 В°F)

Process pressure

Stainles steel version: 0.5 to 10 bar abs
(7.3 to 145 psi abs)
Plastic version: 0.5 to 6 bar abs
(7.3 to 87 psi abs)

TURBIMAX-W CUS65 Suspended solid / turbidity sensor Four Beam Pulsed Light Method 880 nm. Sensor body ss 316 Ti, operating temperature 0 to 50 oC

Complete ultrasonic bed level measuring point

Integral and immersion sensor
Turbidity Analysis Sensor