Endress+Hauser Liquid analysis
Immersion fittings
Process temperaturemax. 150В°C
(302В°F)
max. 10 bar
(145 psi)
Max. 80 В°C (176 В°F)
Process pressureMax. 4 bar at 20В°C
(Max. 58 psi at 68В°F)
Max. 150 В°C (302 В°F)
Process pressureMax. 10 bar (145 psi)
Holder
Process temperature0 to 60 В°C (32 to 140 В°F)
Holder
Process temperature-20 to 60 В°C (-4 to 140 В°F)
Max. 60 В°C
(Max. 140 В°F)
Max. 4 bar relative
(Max. 58 psi relative)
max. 45В°C
Process pressuremax. 4bar
Flow fitting
Process temperaturemax. 50В°C
(max. 122В°F)
max. 6bar
(max.87psi)
Flow fitting
Process temperaturePVDF version: 0 to 120 В°C (32 to 248 В°F)
Stainless steel version: -15 to 150 В°C (5 to 302 В°F)
With EPDM: -15 to 140 В°C (5 to 284 В°F)
PVDF version: max. 8 bar at 50 В°C (max. 116 psi at 122 В°F)
Stainless steel version: max. 10 bar (max. 145 psi)
max. 80В°C
Process pressuremax. 6bar (20В°C)
Flow fitting
Process temperaturemax. 50В°C
(max. 122В°F)
max. 6bar
(max.87psi)
0 .. 60В°C
Process pressure0 .. 6 bars
0 .. 85В°C
Process pressure0 .. 6 bars
Max. 16 bar (relative)
0 to 60 В°C (32 to 140В°F)
Process pressure0 to 4 bar (0 to 58 psi) relative
Liquid Conductivity Sensor
Measurement range2ВµS/cm - 2000 mS/cm
Process temperaturemax. 180В°C (PEEK)
(356В°F)max. 125В°C (PFA)
(254В°F)
max. 20 bar (PEEK)
(290 psi) max. 16 bar (PFA)
(233 psi)
2ВµS/cm to 2000 mS/cm
Process temperaturePEEK: max. 125В°C (max. 260 В°F)
PFA: max. 110В°C (max. 230 В°F)
PEEK: max. 21 bar (max. 304.5 psi)
PFA: max. 17 bar (max. 246.5 psi)
0.1 to 2000 mS/cm
Process temperatureMax. 125В°C (short time up to 140В°C)
max. 257В°F (short time up to 284В°F)
Max. 16 bar at 90 В°C
(Max. 232 psi at 194 В°F)
Liquid Conductivity Sensor
Measurement range100 ВµS/cm - 2000 mS/cm Cell constant k: 6,3 1/cm
Process temperatureProcess temperature: -10В°C - +125В°C
(14В°F - 257В°F)
Sterilisation: 150В°C/5 bar (max. 60 min.)
(302В°F / 72.5 psi)
12 bar(174 psi)/20В°C(68В°F)
8 bar(116 psi)/125В°C(257В°F)
100 ВµS/cm to 2000 mS/cm
Cell constant k: 6.3 1/cm
-10 В°C to 125 В°C (14 В°F to 257 В°F)
Sterilization: 150 В°C at 6 bar abs for max. 60 min
(302 В°F at 87 psi abs for max. 60 min)
13 bar abs up to 90 В°C (188.5 psi abs up to 194 В°F)
9 bar at 125 В°C (130.5 psi abs at 257 В°F)
Liquid analyzer
Liquid analyzer
Ammonium:
0.1 to 1000 mg/l (NH4-N)
Nitrate:
0.1 to 1000 mg/l (NO3-N)
Potassium:
1 to 1000 mg/l
Chloride:
1 to 1000 mg/l
2 В°C to 40В°C (36 to 100 В°F)
Process pressure400 mbar (160 in H2O) max. permitted overpressure
Concentration
Dew Point
Cell Pressure
Cell Temperature
ATEX / IECEx Zone 1
UKEx Zone 1
CSA Class I, Division 1
CSA Class I, Zone 1
One-channel-transmitter
Output / communication0/4-20mA
Ingres protectionFront IP65 , NEMA 4X, Body IP20