Endress+Hauser Liquid analysis

Measurement range

pH 0 to 14

Process temperature

0 to 135 В°C (32 to 275 В°F)

Process pressure

1 to 7 bar abs (14.5 to 101.5 psi)

Measurement range

pH 1 to 12

Process temperature

0 to 80 В°C
(32 to 176 В°F)

Process pressure

1 to 4 bar
(15 to 60 psi)

Measurement range

pH 1 to 13

Process temperature

15 to 80 В°C (5 to 176 В°F)

Process pressure

0.8 to 4 bar (11.6 to 58 psi) (absolute)

Measurement range

Application A
pH: 1 to 12
Application B
pH: 0 to 14

Process temperature

Application A: 15 to 80 В°C (5 to 176 В°F)
Application B: 0 to 135 В°C (32 to 275 В°F)

Process pressure

0.8 to 11 bar (11.6 to 159.5 psi) absolute

Measurement range

1 500 to 1 500 mV

Process temperature

15 to 135 В°C (5 to 275 В°F)

Process pressure

0.8 to 11 bar (11.6 to 159.5 psi) (absolute)

Measurement range

pH 0 to 14

Process temperature

-15 to 135 В°C (5 to 275 В°F)

Process pressure

Max. 11 bar abs at 100 В°C (max. 160 psi at 212 В°F)

Measurement range

pH: 0 to 14

Process temperature

Application N:
0 to 100 В°C (32 to 212 В°F)
Up to 140 В°C (284 В°F) for sterilization

Process pressure

0.8 to 7 bar (11.6 to 101.5 psi) absolute

Measurement range

1 500 to 1 500 mV

Process temperature

0 to 100 В°C (32 to 212 В°F)
0 to 140 В°C (32 to 284 В°F) (140 В°C (284 В°F) or sterilization only)

Process pressure

0.8 to 7 bar (11.6 to 101.5 psi) absolute

Measurement range

Application B:
pH: 0 to 14
Application H:
pH: 0 to 12

Process temperature

1 to 140 В°C (32 to 284 В°F)

Process pressure

0,8 to 14 bar (11,6 to 203 psi) (absolute)

Measurement range

1 500 to 1 500 mV

Process temperature

0 to 140 В°C (32 to 284 В°F)

Process pressure

0.8 to 14 bar (11.6 to 203 psi) (absolute)

Liquid PH and ORP analysis sensor
Measurement range

ORP: 1 500 to 1 500 mV
Application B
pH: 0 to 14
Application H
pH: 0 to 12

Process temperature

Application B and H:
0 to 140 В° C (32 to 284 В° F)
Version TB:
0 to 140 В° C (32 to 284 В° F)
Version TU, TP (pressurized reference):
0 to 140 В° C (32 to 284 В° F) (140 В° C (284 В° F) for sterilization only)
maximum 100 В° C (212 В° F) in continuous operation due to increasing
pressure drop at T> 100 В° C (212 В° F)

Process pressure

Application B: 0.8 to 14 bar (11.6 to 203 psi) absolute
Application H: 0.8 to 7 bar (11.6 to 101,5 psi) absolute

Measurement range

pH 0 to 14

Process temperature

-15 to 135В°C (5 to 275В°F)

Process pressure

Max. 11 bar abs at 100 В°C
(Max. 160 psi at 212 В°F)

Measurement range

1 to 14 pH

Process temperature

0 to 110 В°C (32 to 230 В°F)

Process pressure

0.8 to 14 bar (11.6 to 203 psi) absolute

Measurement range

1 500 to 1 500 mV

Process temperature

0 to 110 В°C (32 to 230 В°F)

Process pressure

0.8 to 14 bar (11.6 to 203 psi) (absolute)

Liquid PH and ORP analysis sensor
Measurement range

ORP: 1 500 to 1 500 mV
pH: 0 to 14

Process temperature

0 to 110 В°C (32 to 230 В°F)

Process pressure

0.8 to 14 bar (11.6 to 203 psi) absolute

Measurement range

pH 0 to 14

Process temperature

-15 to 110 В°C (5 to 230 В°F)

Process pressure

Max. 11 bar abs. at 100 В°C
(Max. 159.5 psi at 212 В°F)

Measuring cable for Memosens sensors
Measurement range

"Depending on the path length and the application the meausring range varies between: TOCeq: 0 to 400 mg/l
CODeq: 0 to 20 000 mg/l
BODeq: 0 to 5000 mg/l
SAC254: 0 to 1000 /m
TU: 0 to 800 FAU
TSS: 0 to 10 000 mg/l
NO3-N: 0 to 500 mg/l
APHA/Hazen: 0 to 500 Hazen

Process temperature

0 to 50В°C
32 to 122 В°F

Process pressure

0.5 to 10 bar abs.
7.3 to 145 psi

Measuring method

UV/VIS Absorbance at 200 to 800 nm

Liquid Conductivity Sensor
Liquid PH and ORP analysis sensor
The device for continuous gas density measurement in the process.
Liquid PH and ORP analysis sensor
Liquid PH and ORP analysis sensor