Endress+Hauser Liquid analysis
Free chlorine transmitter
InputChor / Chlordioxide and pH/ORP Sensor.
Output / communication- Chlor/Chlordioxid, pH, Temperatur : 0/4-20mA- Profibus- Hart + 0/4-20mA
Free chlorine transmitter
InputChorine / Chlordioxide and pH/ORP Sensor.
Output / communication- Chlorine/Chlordioxid, pH, Temperature : 0/4-20mA- Profibus- Hart + 0/4-20mA
Liquid Conductivity Sensor
Input1-channel transmitter
Output / communication0/4-20 mA, Hart, Profibus.
Ingres protectionIP65
One-channel transmitter
Output / communication0/4-20mA, Hart, Profibus.
Ingres protectionIP65
Liquid Oxygen Sensor
Input1-channel transmitter
Output / communication0/4-20mA, Hart, Profibus.
Liquid Oxygen Sensor
Input1-channel transmitter.
Output / communication0/4-20mA, Hart, Profibus.
Liquid PH and ORP analysis sensor
InputOne-channel-transmitter
Output / communication0/4-20 mA, Hart, Profibus.
Ingres protectionIP65
One-channel-transmitter
Output / communication0/4-20mA, Hart, Profibus.
Ingres protectionNo
Liquid Oxygen Sensor
Liquid Oxygen Sensor
Turbidity Analysis Sensor
Conductivity:
0 ВµS/ cm...100 mS/ cm
Build-up thickness:
0 mm...10 mm
-20В°...+100В°C
(-4В°F...+212В°F)
+150В°C (+302В°F) for 1h
Vacuum...25 bar
(Vacuum...362.5 psi)
Capacitive- conductive
Liquid PH and ORP analysis sensor
20 analog (max) (U, I, TC, RTD, frequency, pulse)
20 HART (max) (HART, 4...20mA)
14 digital (max) (control, event and counting inputs)
12 relays (max)
2 analog (max) (I, pulse)
1 transmitter power supply
TFT 7" colour graphic display
TFT 7" colour graphic display with touch panel
internal memory
SD card
USB flash drive
Mass/heat quantity
heat quantity difference
0.1 to 10 mg/l total chlorine
Process temperature5 to 45 В°C
(41 to 113 В°F)
1 to 4 bar (14.5 to 58 psi)
Measuring methodTotal chlorine consists of free chlorine (HOCl, OCl-) and bound chlorine (chloramines)
All components are reduced at the working electrode
Almost pH independent
Trace: 0 to 5 mg/l ClO2
Standard: 0 to 20 mg/l ClO2
High: 0 to 200 mg/l ClO2
0 to 55 В°C , non-freezing
(32 to 130 В°F)
Max. 2 bar abs
(Max. 29 psi abs)
Trace: 0 to 5 mg/l HOCl
Standard: 0 to 20 mg/l HOCl
High: 0 to 200 mg/l HOCl
0 to 55 В°C (32 to 130 В°F), non-freezing
Process pressureMax. 1 bar (max. 14.5 psi)
Measuring methodClosed, membrane covered measuring cell
Reduction of free chlorine at the cathode
Trace: 0 ... 5 mg/l HOBr
Standard: 0 ... 20 mg/l HOBr
High: 0 ... 200 mg/l HOBr
+0...55 В°C (32 ... 130В°F), non-freezing
Process pressureMax. 1 bar (max. 14.5 psi)
0 to 2 mg/l
Process temperature+0 to 45 В°C (32 to 110 В°F), non freezing
Process pressure1 bar (14.5 psi), 2 bar (29 psi) absolute
Measuring method- closed 2 electrode system
- conversion of ozone into a signal current in nA
- signal current is proportional to the concentration of ozone
- the measurement is not pH dependent
5 ОјS/cm to 200 mS/cm
Process temperature0 to 100 В°C (32 to 212 В°F)
Process pressure1 bar, not intended for continues measurment in process
k=0,01: 0.04 to 20 ВµS/cm
k=0,1: 0.10 to 200 ВµS/cm
Threaded with fixed cable:
-20 to 100 В°C (-4 to 212 В°F)
Threaded with plug-in head:
-20 to 120 В°C (-4 to 248 В°F)
Sterilization: max. 140 В°C (284 В°F) for 30 minutes
13 bar at 20 В°C (188 psi at 68 В°F) absolute
1 bar at 120 В°C (14 psi at 248 В°F) absolute
k=0,1: 0,04 to 500 ВµS/cm
Process temperature-5 to 120 В°C (23 to 248 В°F)
For Sterilizsation: max. 150 В°C at 5 bar
(Max. 302 В°F at 73 psi)
13 bar at 20 В°C (188 psi at 68 В°F)
9 bar at 120 В°C (130 psi at 248 В°F)
k=1: 10 ВµS/cm to 20 mS/cm
Process temperature-20 to 135 В°C at 3.5 bar abs
(-4 to 275 В°F at 50 psi)
17 bar abs at 20 В°C
(246 psi at 68 В°F)