Accuracy

Standard:
up to 0.05 %
Platinum:
up to 0.025 %

Process temperature

-40В°C...+150В°C
(-40В°F...+302В°F)

Pressure measuring range

100 mbar...40 bar
(1.5 psi...600 psi)

Main wetted parts

Ceraphire ceramic
FKM, EPDM, HNBR,
Perlast, Kalrez, Chemraz

Material process membrane

Ceramic

Measuring cell

100 mbar....40 bar
(1.5 psi...600 psi)

Accuracy

0.5%

Process temperature

-25...+85В°C
(-13...+185В°F)

Pressure measuring range

400 mbar...+40 bar
(6 psi...+600 psi)

Measuring cell

400 mbar...+40 bar
(6 psi...+600 psi)

Accuracy

0.3%

Process temperature

-40...+100В°C
(-40...+212В°F)

Pressure measuring range

400 mbar...+400 bar
(6...+6000psi)

Measuring cell

+400 mbar...+400 bar
(+6 psi...+6000 psi)

Accuracy

0.3%

Process temperature

-10...+100В°C
(+14...+212В°F)
135В°C for 1h
(275В°F for 1h)

Pressure measuring range

400 mbar...+40 bar
(6...+600psi)

Measuring cell

+400 mbar...+40 bar
(+6 psi...+600 psi)

Pressure transducer

Accuracy

Standard 0.1%
Platinum 0.075%

Process temperature

-40В°C...125В°C
(-40В°F...275В°F)

Pressure measuring range

1 bar...400 bar
(15 psi...6000 psi)

Process pressure absolute / max. overpressure limit

600 bar (9000 psi)

Main wetted parts

316L

Max. measurement distance

4000 m (13.123 ft) H2O

Material process membrane

316L, AlloyC,
Rhodium>Gold

Measuring cell

400mbar...400bar
(15psi...6000psi)
relative/ absolute

Accuracy

Standard:
up to 0.075 %
Platinum
up to 0.055 %

Process temperature

Standard:
-40В°...+125В°C
(-40В°F...+257В°F)
Diaphragm seal:
-40В°C...+400В°C
(-40В°F...+752В°F)

Pressure measuring range

400 mbar... 400 bar
(6psi...6,000psi)

Main wetted parts

316L, AlloyC,
Tantal, Monel,
PTFE

Material process membrane

316L, AlloyC,
Tantal, Monel,
PTFE

Measuring cell

400 mbar...400 bar
(6psi...6,000psi)

Pressure transducer

Accuracy

Standard 0.15%
Platinum 0.075%

Process temperature

-70В°...400В°C
(-94В°F...752В°F)

Pressure measuring range

1 bar...400 bar
(15 psi...6000 psi)

Process pressure absolute / max. overpressure limit

600 bar (9000 psi)

Main wetted parts

316L
AlloyC
Montel
Tantal
Rhodium

Max. measurement distance

4000m (13.123ft) H2O

Material process membrane

316L, AlloyC,
Tantal, PTFE,
Rhodium>Gold

Measuring cell

400 mbar...400 bar
(15 psi...6000 psi)
relative/ absolute

Pressure transducer

Accuracy

Standard: 0.05%
Platinum: up to 0.025%

Process temperature

-40В°C...125В°C
(-40В°F...257В°F)

Pressure measuring range

100mbar...700bar
(1.5psi...10.500psi)

Main wetted parts

Alloy C276
316L
Rhodium

Material process membrane

316L, AlloyC,
Rhodium> Gold

Measuring cell

100 mbar...700 bar
(1.5 psi...10.500 psi)
relative/ absolute

Accuracy

Standard:
up to 0.05 %
Platinum:
up to 0.025 %

Process temperature

Standard:
-40В°...+125В°C
(-40В°F...+257В°F)
Diaphragm seal:
-40В°C...+400В°C
(-40В°F...+752В°F)

Pressure measuring range

400 mbar...700 bar
(1.5 psi...10,500 psi)

Main wetted parts

316L, AlloyC,
Tantal, Monel,
PTFE, Gold

Material process membrane

316L, AlloyC,
Tantal, Monel,
PTFE,
Gold

Measuring cell

400 mbar...700 bar
(6 psi...10,500 psi)

Pressure transducer

Accuracy

0,075% + influence of diaphragm seal

Process temperature

-70В°C...400В°C
(-94В°F...752В°F)

Pressure transducer

Pressure transducer

Pressure transducer

Analog pH electrode for ORP measurement

Measurement range

pH 0-14

Process temperature

-15В°C ... 140В°C
(5В°F - 284В°F)

Process pressure

max. 13 bar
(188 psi)

Digital pH electrode for measuring ORP

Measurement range

pH 0 to 14

Process temperature

0 to 140 В°C (32 to 284 В°F)

Process pressure

1 to 14 bar (15 to 203 psi)

Analog pH electrode for ORP measurement

Measurement range

-1500 mV - +1500 mV

Process temperature

-15В°C - 135В°C

Process pressure

max. 16bar

Digital pH electrode for measuring ORP

Digital pH electrode for measuring ORP

Measurement range

-1500mV - +1500mV

Process temperature

-15В°C - 140В°C

Process pressure

max. 16bar

Analog pH electrode for ORP measurement

Measurement range

pH 0-14

Process temperature

max. 135В°C (274В°F)

Process pressure

max. 10bar (145psi)

Digital pH electrode for measuring ORP

Measurement range

pH 0 to 14

Process temperature

0 to 135 В°C (32 to 275 В°F)

Process pressure

1 to 11 bar abs (15 to 160 psi)

Analog pH electrode for ORP measurement

Measurement range

-1500 mV - +1500 mV

Process temperature

-15В°C - 130В°C

Process pressure

max. 8bar

Digital pH electrode for measuring ORP

Measurement range

-1500 mV - +1500 mV

Process temperature

-15В°C - 130В°C

Process pressure

max. 8bar

Measurement range

pH -2 to 14

Process temperature

0 to 140 В°C
(32 to 280 В°F)

Process pressure

0 to 7 bar abs
(0 to 101.5 psi)

Measuring cell

+100 mbar....+40 bar
(+1.5 psi....600 psi)

Measuring cell

+400 mbar....+400 bar
(+6 psi...+6000 psi)

Measuring cell

+400 mbar....+40 bar
(+6 psi....+600 psi)

Limit pressure switch

Limit pressure switch