art. 11106854
Baumer KTD 4-2 A4 Tachogenerator
- Output signal: 4 - 20 mA
- SSI digital output
- Stainless steel housing
Used for EIL580 incremental encoders with blind or through hollow shaft.
art. 10128295
Hall Sensor MDFK
- 270° linear
- 1,41 °
- ± 0,6 %
- current output
- -40 ... +85 °C
Interference immunity | EN 61000-6-2 |
Emitted interference | EN 61000-6-3 |
Affirmation | CE |
Working temperature | -20...+85 °C |
art. 11033306
Connected to encoders, they easily adapt to the movement of materials, speed, etc.
Smooth synthetic, striped synthetic or striped metal coating.
Development 20 cm / revolution or 50 cm / revolution.
art. 11197171
Solid shaft encoder with EURO flange B10, PMG10 series. art. 11197171
Incremental encodersPOG 10 DN 1024
Baumer POG10 DN 1200 I B5n 14k6x30
art. 11080600
IN STOCK!!!
Tether arm T3
- Accessory for Baumer 11076547
- Prevents overload of the bearing force
- Flexible mounting point orientation
- Adjustable length
- For bolt 1/4”
Voltage supply | 9...26 VDC 5 VDC ±5 % |
Consumption w/o load | ≤100 mA |
Pulses per revolution | 250...2500 |
Operating temperature | -20...+85 °C |
Voltage supply | 9...30 VDC |
Consumption w/o load | ≤100 mA (per interface SSI) ≤250 mA (per interface bus) |
Initializing time | ≤200 ms after power on |
Operating temperature | -20...+85 °C |
Interference immunity | EN 61000-6-2 |
Emitted interference | EN 61000-6-3 |
Approval | CE |
Operating temperature | -20...+85 °C |
Voltage supply | 7...30 VDC |
Consumption w/o load | ≤100 mA |
Initializing time | ≤200 ms after power on |
Operating temperature | -20...+85 °C |
Power supply : 24 V
Incremental signals : 1Vpp
Line count : 2048
Voltage supply | 9...30 VDC |
Consumption w/o load | ≤100 mA (per interface SSI) ≤250 mA (per interface bus) |
Initializing time | ≤200 ms after power on |
Operating temperature | -20...+85 °C |
Absolute encoders AMG 81
- For replacement of "PY" or "BC" style tachogenerators
- Low response time
- Open circuit voltage 20...100 mV per rpm
- Very high resistance to shock
- High signal quality due to patented LongLife technology
- Recognition of sense of rotation possible via control
- CSA / C / US approved
Voltage supply | 8...26 VDC |
Reverse polarity protection | Yes |
Consumption w/o load | ≤40 mA (24 VDC) |
Operating temperature | -20...+85 °C |
Voltage supply | +UB= 12...30 VDC (IS-/IE-/US-/UT-version) -UB= -12...-26 VDC / +UB 12...30 VDC (UE-/UR-version) |
Reverse polarity protection | Yes |
Consumption w/o load | ≤50 mA (24 VDC) |
Operating temperature | -20...+85 °C |
Voltage supply | 10...30 VDC |
Reverse polarity protection | Yes |
Consumption w/o load | ≤150 mA (24 VDC) |
Operating temperature | -20...+85 °C |
Voltage supply | 10...30 VDC |
Reverse polarity protection | Yes |
Consumption w/o load | ≤150 mA (24 VDC) |
Operating temperature | -20...+85 °C |
Voltage supply | 10...30 VDC |
Reverse polarity protection | Yes |
Consumption w/o load | ≤70 mA (24 VDC) |
Operating temperature | -20...+85 °C |
Inputs | SSI clock Zero setting input |
Voltage supply | 10...30 VDC |
Reverse polarity protection | Yes |
Consumption w/o load | ≤50 mA (24 VDC) |
Operating temperature | -30...+85 °C |
Voltage supply | 10...30 VDC |
Reverse polarity protection | Yes |
Consumption w/o load | ≤70 mA (24 VDC) |
Operating temperature | -20...+85 °C |
Inputs | SSI clock Zero setting input |
Voltage supply | 10...30 VDC |
Reverse polarity protection | Yes |
Consumption w/o load | ≤60 mA (24 VDC) |
Operating temperature | -30...+85 °C |
Voltage supply | 10...30 VDC |
Reverse polarity protection | Yes |
Consumption w/o load | ≤150 mA (24 VDC) |
Operating temperature | -20...+85 °C |
Voltage supply | 10...30 VDC |
Reverse polarity protection | Yes |
Consumption w/o load | ≤70 mA (24 VDC) |
Operating temperature | -20...+85 °C |
Inputs | SSI clock Zero setting input |